Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 210

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Efficacy of Left Atrial Voltage‐Based Catheter Ablation of Persistent Atrial Fibrillation

YAMAGUCHI, TAKANORI, TSUCHIYA, TAKESHI, NAKAHARA, SHIRO, FUKUI, AKIRA, NAGAMOTO, YASUTSUGU, MUROTANI, KENTA, ESHIMA, KENICHI, TAKAHASHI, NAOHIKO · 2016 · Journal of Cardiovascular Electrophysiology

Abstract

Low Voltage‐Based Ablation for Atrial Fibrillation: Background: Low‐voltage zones (LVZs) represent fibrotic tissue and are substrates for atrial fibrillation (AF). We hypothesized that LVZ‐based substrate modification along with pulmonary vein isolation (PVI) would improve outcomes in persistent AF (PeAF) patients with LVZs, whereas PVI alone would work in patients without LVZs. Methods and Results: Voltage mapping of the left atrium (LA) was performed during sinus rhythm in 101 PeAF patients in whom LVZ was defined as an area with bipolar electrograms <0.5 mV. Thirty‐nine patients had LVZs and underwent ablation of the entire LVZ area after PVI (LVZabl group). In the remaining 62 patients without LVZs, PVI alone was performed with no further substrate modifications (PVI group). An additional group of 16 consecutive PeAF patients with LVZ did not undergo any substrate modification after PVI and were used as a comparison group (LVZnon‐abl group) despite having similar size of LVZs to that in the LVZabl group. After a single session, 28 (72%) patients in the LVZabl group had no recurrence, whereas 49 (79%) patients in the PVI group had no recurrence during 18 ± 7 months of follow‐up (log‐rank, P = 0.400). In the LVZnon‐abl group, only 6 patients (38%) had no recurrence during 32 ± 7 months of follow‐up, even after a mean number of sessions of 1.8 (log‐rank, P < 0.001, compared with the LVZabl group). Conclusions: Additional LVZ‐based substrate modification after PVI improved the outcome in PeAF patients with LVZs, whereas PVI alone worked in patients without LVZs, even in those with PeAF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/jce.13019

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
YAMAGUCHI, T., TSUCHIYA, T., NAKAHARA, S., FUKUI, A., NAGAMOTO, Y., MUROTANI, K., ESHIMA, K., & TAKAHASHI, N.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2016-06-30
Volume
27
Issue
9
Pages
1055-1063
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2405759780
Cited by
210
References
3
FWCI
15.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.