Accelerating Medical Systematic Reviews With Large Language Models: Performance, Consistency, and Potential Issues
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index; none of the 28 sources its claims cite is checked for support yet.
Overview
CoChat Summary
TL;DR
This systematic review of 168 empirical studies found LLMs most useful for screening and first-pass extraction but unreliable for literature search and quality assessment, with wide performance ranges. It concludes LLMs should serve as human-verified copilots, not autonomous replacements.
Key findings
- Across 168 included studies, screening tasks showed the most favorable but uneven results: median recall was approximately 0.88 (IQR 0.67–0.97), specificity median 0.87 (IQR 0.66–0.96), and precision median 0.75 (IQR 0.34–0.92), with frequent over-inclusion of irrelevant citations.
- Data extraction had median accuracy approximately 0.81 and median F1 approximately 0.81; performance was adequate for standardized text elements but declined for numerical data from complex tables or non-standardized text, so human verification remained indispensable for statistical extraction.
- LLMs were least reliable in literature searching and quality assessment: search models hallucinated citations or misapplied Boolean logic and had recall below specialist-designed searches; quality assessment had median Cohen’s κ approximately 0.64 (IQR 0.43–0.83; range −0.16 to 1.00), with several trials below 0.4.
- Efficiency gains were substantial but heterogeneous: median fold-reduction in time was approximately 4 (IQR 0.73–33.69), and work saved over sampling had median approximately 0.64 (IQR 0.40–0.80). One-or-few-shot prompting with chain-of-thought had the highest median recall (0.97) versus zero-shot chain-of-thought (0.72), but subgroups were small, heterogeneous, and unadjusted.
Methods
- Systematic review of empirical primary studies reporting original quantitative evaluations of publicly accessible LLMs in medical evidence synthesis across five stages: literature search, title-and-abstract screening, full-text screening, data extraction, and quality assessment. Searches covered PubMed, Web of Science, and Scopus from January 1, 2021 through November 25, 2024, were re-run through March 5, 2026, and updated July 1, 2026; inclusion was restricted to English-language reports.
- Two reviewers independently screened titles and abstracts (Cohen’s κ = 0.85) and full texts (Cohen’s κ = 0.76), with disagreements resolved by discussion. The review was not prospectively registered; the draft protocol and amendment log are in the Supporting Information.
- Synthesis was primarily descriptive. An extracted metric record was one numerical estimate for one outcome under a distinct evaluation condition; records were summarized using median, IQR, and full observed range. Prompt strategy was coded descriptively. Random-effects pooling was secondary and exploratory, limited to estimates with variance information.
Limitations
- The paper states: inclusion was restricted to English-language reports; the evidence base evolves faster than any single search can fully capture; the review was deliberately limited to five core stages and did not evaluate protocol registration, question formulation, evidence mapping, statistical synthesis, or report writing; and heterogeneity of metrics, tasks, and model versions precluded firm pooled conclusions, so quantitative summaries should be read as descriptive.
- The paper also states: no search can wholly exclude the risk of missing studies of newly released models; the review was not prospectively registered; and prompt subgroups were small, heterogeneous, and unadjusted, so no consistent causal advantage should be attributed to a specific prompting strategy.
- Additional cautions stated in the text: hallucination is a critical risk, including fabrication of references or data points; models can be overly agreeable or overly aggressive in exclusion under workload-reduction prompts; proprietary-model opacity and frequent updates challenge reproducibility; and transparent reporting of exact model version, temperature/settings, verbatim prompts, and extent of human verification is essential. The text also notes wide performance ranges mean aggregate optimism can be misleading and performance should be verified within each individual review.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 1 Not valid · 21 Not checked · 37 Own results and interpretations
None of the sources cited for this claim have been checked yet.
In the paper
“In data extraction, LLMs structured information from clinicaltrial reports with a median accuracy of approximately 0.81”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“One-or few-shot prompting combined with chain-of-thought had the highest median recall (0.97)”
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“specificity (median = 0.87, IQR 0.66-0.96)”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
In the paper
“LLMs generally showed higher internal consistency (reproducibility across repeated runs of the same prompt) than agreement with human reviewers”
What the sources say
- Not matchedcites [18]
The reference list we hold has no entry [18].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Newer model versions tended to perform better”
hedgedstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
22 more claims
Create a free account to see all 59 claims and every source verdict.
- It may state two separate claims as one. 21
- Probably not a substantial claim. 20
Citations
Cites
On the Opportunities and Risks of Foundation Models
Bommasani, R., Hudson, D. A., Adeli, E., Altman, R., Arora, S., von Arx, S., Bernstein, M. S., Bohg, J., Bosselut, A., Brunskill, E., et al. (2021) · arXiv · doi:10.48550/arxiv.2108.07258 · Cited by 2,676
A Survey of Large Language Models
Zhao, W. X., Zhou, K., Li, J., Tang, T., Dong, Z., Hou, Y., Zhang, B., Min, Y., Zhang, J., Liu, P., et al. (2026) · Frontiers of Computer Science · doi:10.1007/s11704-026-60308-3 · Cited by 2,093
Borah, R., Brown, A. W., Capers, P. L., & Kaiser, K. A. (2017) · BMJ Open · doi:10.1136/bmjopen-2016-012545 · Cited by 737
Chelli, M., Descamps, J., Lavoué, V., Trojani, C., Azar, M., Deckert, M., Raynier, J.-L., Clowez, G., Boileau, P., & Ruetsch-Chelli, C. (2024) · Journal of Medical Internet Research · doi:10.2196/53164 · Cited by 602
Qureshi, R., Shaughnessy, D., Gill, K. A. R., Robinson, K. A., Li, T., & Agai, E. (2023) · Systematic Reviews · doi:10.1186/s13643-023-02243-z · Cited by 201
Data extraction for evidence synthesis using a large language model: A proof-of-concept study
Gartlehner, G., Kahwati, L., Hilscher, R., Thomas, I., Kugley, S., Crotty, K., Viswanathan, M., Nussbaumer‐Streit, B., Booth, G., Erskine, N., et al. (2024) · Research Synthesis Methods · doi:10.1002/jrsm.1710 · Cited by 164
Scherbakov, D., Hubig, N., Jansari, V., Bakumenko, A., & Lenert, L. A. (2024) · arXiv · doi:10.48550/arxiv.2409.04600 · Cited by 156
Scherbakov, D., Hubig, N., Jansari, V., Bakumenko, A., & Lenert, L. A. (2025) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocaf063 · Cited by 154
Lieberum, J.-L., Toews, M., Metzendorf, M.-I., Heilmeyer, F., Siemens, W., Haverkamp, C., Böhringer, D., Meerpohl, J. J., & Eisele-Metzger, A. (2025) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2025.111746 · Cited by 148
Development of Prompt Templates for Large Language Model–Driven Screening in Systematic Reviews
Cao, C., Sang, J., Arora, R., Chen, D., Kloosterman, R., Cecere, M., Gorla, J., Saleh, R., Drennan, I., Teja, B., et al. (2025) · Annals of Internal Medicine · doi:10.7326/annals-24-02189 · Cited by 91
Metadata
- Authors
- Hu, B., Xia, Z., & Geng, L.
- Affiliations
- Nanjing University (CN)
- Stanford University (US)
- Corresponding author
- Geng, Liuna
- Venue
- Journal of Evidence-Based Medicine
- Publisher
- Wiley
- Published
- 2026-11-01
- Pages
- e70207
- ISSN
- 1756-5391 (ISSN-L)
- 1756-5383
- OpenAlex
- W7225124362
- Cited by
- 0
- References
- 19
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- onlinelibrary.wiley.com/termsAndConditions#vor (vor)
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm)
- Locations
- Journal of Evidence-Based Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Office for Philosophy and Social Sciences (22&ZD188)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Computer Science › Information Systems › Information Retrieval and Search Behavior
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- large language models, AI-assisted literature review, performance evaluation, consistency
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-26, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-26 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accelerating Medical Systematic Reviews With Large Language Models: Performance, Consistency, and Potential Issues. https://app.cochat.ai/papers/10.1111/jebm.70207
- The paper
- Hu, B., Xia, Z., & Geng, L. (2026). Accelerating Medical Systematic Reviews With Large Language Models: Performance, Consistency, and Potential Issues. Journal of Evidence-Based Medicine. https://doi.org/10.1111/jebm.70207
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.