Underreporting of Robotic Surgery Complications
The DOI matches its Crossref record.
Abstract
BACKGROUND: Since its Food and Drug Administration (FDA) approval, robot-assisted laparoscopic surgery has grown with expanding indications. One factor used to expand indications is device-related complications. We designed a study to evaluate device-related robotic surgery complications reported to FDA. METHODS: We searched the FDA device-related complication database, LexisNexis, and PACER (Public Access to Court Electronic Records) to identify robotic surgery-related complications over a 12-year period (January 1, 2000 to August 1, 2012). Cases from LexisNexis and PACER were cross-referenced with the FDA database to determine cases where an FDA report was inaccurate, filed late or not filed. RESULTS: A total of 245 events were reported to the FDA during the study period, including 71 deaths and 174 nonfatal injuries. Median time to report an event to the FDA was 30 days (range = 0-930 days). Eight cases were identified from the LexisNexis and PACER searches where FDA reports were improperly filed. In five of these, no report was filed with a mean follow-up of 4.1 years (range = 2.3-5.8 years). In the three cases where a report was filed, the mean time between the event and the FDA report was 20.4 months (611 days, range = 292-930 days). CONCLUSIONS: It is important that the true incidence of complications with robotic-assisted laparoscopic surgery be known to ensure continued safe innovation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Adverse Events in Robotic Surgery: A Retrospective Study of 14 Years of FDA Data
Alemzadeh, H., Raman, J., Leveson, N., Kalbarczyk, Z., & Iyer, R. K. (2016) · PLOS ONE · doi:10.1371/journal.pone.0151470 · Cited by 441
O'Sullivan, S., Nevejans, N., Allen, C., Blyth, A., Leonard, S., Pagallo, U., Holzinger, K., Holzinger, A., Sajid, M. I., & Ashrafian, H. (2019) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1968 · Cited by 437
“Cooper et al (2013) 36 suggest the use of a black box to identify dysfunctions.”
BackgroundRobots in Groups and Teams: A Literature Review
Sebo, S., Stoll, B., Scassellati, B., & Jung, M. F. (2020) · Proceedings of the ACM on Human-Computer Interaction · doi:10.1145/3415247 · Cited by 158
“Similarly, this excludes numerous studies conducted using remote-controlled robotics such as rovers [165, 182], rescue robots and drones [125], and surgical robots [15, 28, 36, 135], since these robots fulfill more the role of robotic tools rather than autonomous agents.”
Background
Metadata
- Authors
- Cooper, M. A., Ibrahim, A., Lyu, H., & Makary, M. A.
- Venue
- Journal for Healthcare Quality
- Published
- 2015-03
- Volume
- 37
- Issue
- 2
- Pages
- 133-138
- ISSN
- 1062-2551 (ISSN-L)
- OpenAlex
- W2149258477
- Cited by
- 112
- References
- 0
- FWCI
- 12.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Underreporting of Robotic Surgery Complications. https://app.cochat.ai/papers/10.1111/jhq.12036
- The paper
- Cooper, M. A., Ibrahim, A., Lyu, H., & Makary, M. A. (2015). Underreporting of Robotic Surgery Complications. Journal for Healthcare Quality. https://doi.org/10.1111/jhq.12036
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.