The DOI matches its Crossref record.
Clinical complications of urinary catheters caused by crystalline biofilms: something needs to be done
Open accessAbstract
This review is largely based on a previous paper published in the journal Spinal Cord. The care of many patients undergoing long‐term bladder catheterization is complicated by encrustation and blockage of their F oley catheters. This problem stems from infection by urease‐producing bacteria, particularly P roteus mirabilis. These organisms colonize the catheter forming an extensive biofilm; they also generate ammonia from urea, thus elevating the pH of urine. As the pH rises, crystals of calcium and magnesium phosphates precipitate in the urine and in the catheter biofilm. The continued development of this crystalline biofilm blocks the flow of urine through the catheter. Urine then either leaks along the outside of the catheter and the patient becomes incontinent or is retained causing painful distension of the bladder and reflux of urine to the kidneys. The process of crystal deposition can also initiate stone formation. Most patients suffering from recurrent catheter encrustation develop bladder stones. P. mirabilis establishes stable residence in these stones and is extremely difficult to eliminate from the catheterized urinary tract by antibiotic therapy. If blocked catheters are not identified and changed, serious symptomatic episodes of pyelonephritis, septicaemia and endotoxic shock can result. All types of Foley catheters including silver‐ or nitrofurazone‐coated devices are vulnerable to this problem. In this review, the ways in which biofilm formation on Foley catheters is initiated by P. mirabilis will be described. The implications of understanding these mechanisms for the development of an encrustation‐resistant catheter will be discussed. Finally, the way forward for the prevention and control of this problem will be considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Urinary tract infections: epidemiology, mechanisms of infection and treatment options
Flores-Mireles, A. L., Walker, J. N., Caparon, M., & Hultgren, S. J. (2015) · Nature Reviews Microbiology · doi:10.1038/nrmicro3432 · Cited by 4,213
A review of the recent advances in antimicrobial coatings for urinary catheters
Singha, P., Locklin, J., & Handa, H. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.11.070 · Cited by 448
Pathogenesis of Proteus mirabilis Infection
Armbruster, C. E., Mobley, H. L. T., & Pearson, M. M. (2018) · EcoSal Plus · doi:10.1128/ecosalplus.esp-0009-2017 · Cited by 409
Proteus mirabilis UreR coordinates cellular functions required for urease activity
Fitzgerald, M. J., Pearson, M. M., & Mobley, H. L. T. (2024) · Journal of Bacteriology · doi:10.1128/jb.00031-24 · Cited by 18
Metadata
- Authors
- Stickler, D. J.
- Venue
- Journal of Internal Medicine
- Publisher
- Wiley
- Published
- 2014-07-14
- Volume
- 276
- Issue
- 2
- Pages
- 120-129
- ISSN
- 0954-6820 (ISSN-L)
- 1365-2796
- OpenAlex
- W1967490292
- Cited by
- 223
- References
- 0
- FWCI
- 9.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical complications of urinary catheters caused by crystalline biofilms: something needs to be done. https://app.cochat.ai/papers/10.1111/joim.12220
- The paper
- Stickler, D. J. (2014). Clinical complications of urinary catheters caused by crystalline biofilms: something needs to be done. Journal of Internal Medicine. https://doi.org/10.1111/joim.12220
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.