MIMoSA: An Automated Method for Intermodal Segmentation Analysis of Multiple Sclerosis Brain Lesions
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND PURPOSE: Magnetic resonance imaging (MRI) is crucial for in vivo detection and characterization of white matter lesions (WMLs) in multiple sclerosis. While WMLs have been studied for over two decades using MRI, automated segmentation remains challenging. Although the majority of statistical techniques for the automated segmentation of WMLs are based on single imaging modalities, recent advances have used multimodal techniques for identifying WMLs. Complementary modalities emphasize different tissue properties, which help identify interrelated features of lesions. METHODS: Method for Inter‐Modal Segmentation Analysis (MIMoSA), a fully automatic lesion segmentation algorithm that utilizes novel covariance features from intermodal coupling regression in addition to mean structure to model the probability lesion is contained in each voxel, is proposed. MIMoSA was validated by comparison with both expert manual and other automated segmentation methods in two datasets. The first included 98 subjects imaged at Johns Hopkins Hospital in which bootstrap cross‐validation was used to compare the performance of MIMoSA against OASIS and LesionTOADS, two popular automatic segmentation approaches. For a secondary validation, a publicly available data from a segmentation challenge were used for performance benchmarking. RESULTS: In the Johns Hopkins study, MIMoSA yielded average Sørensen‐Dice coefficient (DSC) of .57 and partial AUC of .68 calculated with false positive rates up to 1%. This was superior to performance using OASIS and LesionTOADS. The proposed method also performed competitively in the segmentation challenge dataset. CONCLUSION: MIMoSA resulted in statistically significant improvements in lesion segmentation performance compared with LesionTOADS and OASIS, and performed competitively in an additional validation study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep learning in medical image analysis
Shen, D., Wu, G., & Suk, H.-I. (2017) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071516-044442 · Cited by 4,968
Warfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,335 · cited 1×
“37 In addition, we label-fused MIMoSA segmentation masks from models trained on rater 1 and trained on rater 2 using STAPLE.”
MethodClassifier Technology and the Illusion of Progress
Hand, D. J. (2006) · Statistical Science · doi:10.1214/088342306000000060 · Cited by 723 · cited 1×
“13 Such studies have emphasized the importance of biologically relevant feature selection.”
BackgroundGhafoorian, M., Karssemeijer, N., Heskes, T., van Uden, I. W. M., Sanchez, C. I., Litjens, G., de Leeuw, F.-E., van Ginneken, B., Marchiori, E., & Platel, B. (2017) · Scientific Reports · doi:10.1038/s41598-017-05300-5 · Cited by 236 · cited 1×
“12 In the past, studies have compared classification methods and shown that simple methods often yield the performance equivalent to more sophisticated methods.”
ResultSubject-level measurement of local cortical coupling
Vandekar, S. N., Shinohara, R. T., Raznahan, A., Hopson, R. D., Roalf, D. R., Ruparel, K., Gur, R. C., Gur, R. E., & Satterthwaite, T. D. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.03.002 · Cited by 27
Self-citation
Cited by
Evaluating White Matter Lesion Segmentations with Refined Sørensen-Dice Analysis
Carass, A., Roy, S., Gherman, A., Reinhold, J. C., Jesson, A., Arbel, T., Maier, O., Handels, H., Ghafoorian, M., Platel, B., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-64803-w · Cited by 185
Self-citationGabr, R. E., Coronado, I., Robinson, M., Sujit, S. J., Datta, S., Sun, X., Allen, W. J., Lublin, F. D., Wolinsky, J. S., & Narayana, P. A. (2020) · Multiple Sclerosis Journal · doi:10.1177/1352458519856843 · Cited by 92
La Rosa, F., Wynen, M., Al-Louzi, O., Beck, E. S., Huelnhagen, T., Maggi, P., Thiran, J.-P., Kober, T., Shinohara, R. T., Sati, P., et al. (2022) · NeuroImage: Clinical · doi:10.1016/j.nicl.2022.103205 · Cited by 58
Self-citationCentral vein sign for multiple sclerosis: A systematic review and meta-analysis
Bhandari, A., Xiang, H., Lechner-Scott, J., & Agzarian, M. (2020) · Clinical Radiology · doi:10.1016/j.crad.2020.01.011 · Cited by 31
Metadata
- Authors
- Valcarcel, A. M., Linn, K. A., Vandekar, S. N., Satterthwaite, T. D., Muschelli, J., Calabresi, P. A., Pham, D. L., Martin, M. L., & Shinohara, R. T.
- Venue
- Journal of Neuroimaging
- Publisher
- Wiley
- Published
- 2018-03-08
- Volume
- 28
- Issue
- 4
- Pages
- 389-398
- ISSN
- 1051-2284 (ISSN-L)
- 1552-6569
- OpenAlex
- W2789235061
- Cited by
- 61
- References
- 5
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MIMoSA: An Automated Method for Intermodal Segmentation Analysis of Multiple Sclerosis Brain Lesions. https://app.cochat.ai/papers/10.1111/jon.12506
- The paper
- Valcarcel, A. M., Linn, K. A., Vandekar, S. N., Satterthwaite, T. D., Muschelli, J., Calabresi, P. A., Pham, D. L., Martin, M. L., & Shinohara, R. T. (2018). MIMoSA: An Automated Method for Intermodal Segmentation Analysis of Multiple Sclerosis Brain Lesions. Journal of Neuroimaging. https://doi.org/10.1111/jon.12506
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.