Standardization of extracellular vesicle measurements by flow cytometry through vesicle diameter approximation
Open accessAbstract
Unlabelled Box •Platelet extracellular vesicles (EVs) concentrations measured by flow cytometers are incomparable. •A model is applied to convert ambiguous scatter units to EV diameter in nanometer. •Most included flow cytometers lack the sensitivity to detect EVs of 600 nm and smaller. •The model outperforms polystyrene beads for comparability of platelet EV concentrations. Summary: Background Detection of extracellular vesicles (EVs) by flow cytometry has poor interlaboratory comparability, owing to differences in flow cytometer (FCM) sensitivity. Previous workshops distributed polystyrene beads to set a scatter‐based diameter gate in order to improve the comparability of EV concentration measurements. However, polystyrene beads provide limited insights into the diameter of detected EVs. Objectives To evaluate gates based on the estimated diameter of EVs instead of beads. Methods A calibration bead mixture and platelet EV samples were distributed to 33 participants. Beads and a light scattering model were used to set EV diameter gates in order to measure the concentration of CD61–phycoerythrin‐positive platelet EVs. Results Of the 46 evaluated FCMs, 21 FCMs detected the 600–1200‐nm EV diameter gate. The 1200–3000‐nm EV diameter gate was detected by 31 FCMs, with a measured EV concentration interlaboratory variability of 81% as compared with 139% with the bead diameter gate. Part of the variation in both approaches is caused by precipitation in some of the provided platelet EV samples. Flow rate calibration proved essential because systems configured to 60 μL min −1 differed six‐fold in measured flow rates between instruments. Conclusions EV diameter gates improve the interlaboratory variability as compared with previous approaches. Of the evaluated FCMs, 24% could not detect 400‐nm polystyrene beads, and such instruments have limited utility for EV research. Finally, considerable differences were observed in sensitivity between optically similar instruments, indicating that maintenance and training affect the sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Théry, C., Witwer, K. W., Aikawa, E., Alcaraz, M. J., Anderson, J. D., Andriantsitohaina, R., Antoniou, A., Arab, T., Archer, F., Atkin‐Smith, G. K., et al. (2018) · Journal of Extracellular Vesicles · doi:10.1080/20013078.2018.1535750 · Cited by 11,099
Self-citationWelsh, J. A., Goberdhan, D. C. I., O'Driscoll, L., Buzas, E. I., Blenkiron, C., Bussolati, B., Cai, H., Di Vizio, D., Driedonks, T. A. P., Erdbrügger, U., et al. (2024) · Journal of Extracellular Vesicles · doi:10.1002/jev2.12404 · Cited by 4,663
Self-citationGuidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdis, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 979
Self-citationFormation of a protein corona on the surface of extracellular vesicles in blood plasma
Tóth, E. Á., Turiák, L., Visnovitz, T., Cserép, C., Mázló, A., Sódar, B. W., Försönits, A. I., Petővári, G., Sebestyén, A., Komlósi, Z., et al. (2021) · Journal of Extracellular Vesicles · doi:10.1002/jev2.12140 · Cited by 522
Self-citationExtracellular vesicle isolation methods: rising impact of size-exclusion chromatography
Monguió-Tortajada, M., Gálvez-Montón, C., Bayes-Genis, A., Roura, S., & Borràs, F. E. (2019) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-019-03071-y · Cited by 438
Metadata
- Authors
- van der Pol, E., Sturk, A., van Leeuwen, T., Nieuwland, R., Coumans, F., Mobarrez, F., Arkesteijn, G., Wauben, M., Siljander, P. R. ‐., Sánchez‐López, V., Otero‐Candelera, R., Ramón, L. A., Dolz, S., Vila, V., Mackman, N., Geddings, J., Mullier, F., Bailly, N., Han, J. ‐., Kwaan, H. C., Weiss, I. M., Buzás, E. I., Pállinger, E., Harrison, P., Kraan, J., Hedley, B. D., LazoLangner, A., Enjeti, A., Norris, P. J., Paris, C., Susen, S., Bonnefoy, A., Delorme, I., Chandler, W. L., Hau, C., Aass, H. C. D., Connor, D., Wu, X., Dragovic, R., Uotila, L. M., Lacroix, R., & Robert, S.
- Venue
- Journal of Thrombosis and Haemostasis
- Publisher
- Elsevier BV
- Published
- 2018-06
- Volume
- 16
- Issue
- 6
- Pages
- 1236-1245
- ISSN
- 1538-7836 (ISSN-L)
- OpenAlex
- W2793809429
- Cited by
- 182
- References
- 0
- FWCI
- 7.06
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Standardization of extracellular vesicle measurements by flow cytometry through vesicle diameter approximation. https://app.cochat.ai/papers/10.1111/jth.14009
- The paper
- van der Pol, E., Sturk, A., van Leeuwen, T., Nieuwland, R., Coumans, F., Mobarrez, F., Arkesteijn, G., Wauben, M., Siljander, P. R. ‐., Sánchez‐López, V., Otero‐Candelera, R., Ramón, L. A., Dolz, S., Vila, V., Mackman, N., Geddings, J., Mullier, F., Bailly, N., Han, J. ‐., . . . Robert, S. (2018). Standardization of extracellular vesicle measurements by flow cytometry through vesicle diameter approximation. Journal of Thrombosis and Haemostasis. https://doi.org/10.1111/jth.14009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.