Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 182

The DOI matches its Crossref record.

Standardization of extracellular vesicle measurements by flow cytometry through vesicle diameter approximation

Open access
van der Pol, E., Sturk, A., van Leeuwen, T., Nieuwland, R., Coumans, F., Mobarrez, F., Arkesteijn, G., Wauben, M., Siljander, P. R.‐M., Sánchez‐López, V., Otero‐Candelera, R., Ramón, L.A., Dolz, S., Vila, V., Mackman, N., Geddings, J., Mullier, F., Bailly, N., Han, J.‐Y., Kwaan, H.C., Weiss, I.M., Buzás, E.I., Pállinger, E., Harrison, P., Kraan, J., Hedley, B.D., LazoLangner, A., Enjeti, A., Norris, P.J., Paris, C., Susen, S., Bonnefoy, A., Delorme, I., Chandler, W.L., Hau, C., Aass, H.C.D., Connor, D., Wu, X., Dragovic, R., Uotila, L.M., Lacroix, R., Robert, S.·2018·Journal of Thrombosis and Haemostasis

Abstract

Unlabelled Box •Platelet extracellular vesicles (EVs) concentrations measured by flow cytometers are incomparable. •A model is applied to convert ambiguous scatter units to EV diameter in nanometer. •Most included flow cytometers lack the sensitivity to detect EVs of 600 nm and smaller. •The model outperforms polystyrene beads for comparability of platelet EV concentrations. Summary: Background Detection of extracellular vesicles (EVs) by flow cytometry has poor interlaboratory comparability, owing to differences in flow cytometer (FCM) sensitivity. Previous workshops distributed polystyrene beads to set a scatter‐based diameter gate in order to improve the comparability of EV concentration measurements. However, polystyrene beads provide limited insights into the diameter of detected EVs. Objectives To evaluate gates based on the estimated diameter of EVs instead of beads. Methods A calibration bead mixture and platelet EV samples were distributed to 33 participants. Beads and a light scattering model were used to set EV diameter gates in order to measure the concentration of CD61–phycoerythrin‐positive platelet EVs. Results Of the 46 evaluated FCMs, 21 FCMs detected the 600–1200‐nm EV diameter gate. The 1200–3000‐nm EV diameter gate was detected by 31 FCMs, with a measured EV concentration interlaboratory variability of 81% as compared with 139% with the bead diameter gate. Part of the variation in both approaches is caused by precipitation in some of the provided platelet EV samples. Flow rate calibration proved essential because systems configured to 60 μL min −1 differed six‐fold in measured flow rates between instruments. Conclusions EV diameter gates improve the interlaboratory variability as compared with previous approaches. Of the evaluated FCMs, 24% could not detect 400‐nm polystyrene beads, and such instruments have limited utility for EV research. Finally, considerable differences were observed in sensitivity between optically similar instruments, indicating that maintenance and training affect the sensitivity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/jth.14009

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 182

Metadata

Authors
van der Pol, E., Sturk, A., van Leeuwen, T., Nieuwland, R., Coumans, F., Mobarrez, F., Arkesteijn, G., Wauben, M., Siljander, P. R. ‐., Sánchez‐López, V., Otero‐Candelera, R., Ramón, L. A., Dolz, S., Vila, V., Mackman, N., Geddings, J., Mullier, F., Bailly, N., Han, J. ‐., Kwaan, H. C., Weiss, I. M., Buzás, E. I., Pállinger, E., Harrison, P., Kraan, J., Hedley, B. D., LazoLangner, A., Enjeti, A., Norris, P. J., Paris, C., Susen, S., Bonnefoy, A., Delorme, I., Chandler, W. L., Hau, C., Aass, H. C. D., Connor, D., Wu, X., Dragovic, R., Uotila, L. M., Lacroix, R., & Robert, S.
Venue
Journal of Thrombosis and Haemostasis
Publisher
Elsevier BV
Published
2018-06
Volume
16
Issue
6
Pages
1236-1245
ISSN
1538-7836 (ISSN-L)
OpenAlex
W2793809429
Cited by
182
References
0
FWCI
7.06
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Standardization of extracellular vesicle measurements by flow cytometry through vesicle diameter approximation. https://app.cochat.ai/papers/10.1111/jth.14009
The paper
van der Pol, E., Sturk, A., van Leeuwen, T., Nieuwland, R., Coumans, F., Mobarrez, F., Arkesteijn, G., Wauben, M., Siljander, P. R. ‐., Sánchez‐López, V., Otero‐Candelera, R., Ramón, L. A., Dolz, S., Vila, V., Mackman, N., Geddings, J., Mullier, F., Bailly, N., Han, J. ‐., . . . Robert, S. (2018). Standardization of extracellular vesicle measurements by flow cytometry through vesicle diameter approximation. Journal of Thrombosis and Haemostasis. https://doi.org/10.1111/jth.14009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.