Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 178

The DOI matches its Crossref record.

Ammonia clearance with haemofiltration in adults with liver disease

Slack, Andrew J., Auzinger, Georg, Willars, Chris, Dew, Tracy, Musto, Rebecca, Corsilli, Daniel, Sherwood, Roy, Wendon, Julia A., Bernal, William · 2014 · Liver International

Abstract

Background & Aims: Ammonia is recognized as a toxin central to complications of liver failure. Hyperammonaemia has important clinical consequences, but optimal means to reduce circulating levels are uncertain. In patients with liver disease, continuous renal replacement therapy ( CRRT ) with haemofiltration ( HF ) is often required to treat concurrent kidney injury, but its effects upon ammonia levels are poorly characterized. To evaluate the effect of HF at different treatment intensities on ammonia clearance ( AC ) and arterial ammonia concentration. Methods: Prospective study of adult patients with liver failure and arterial ammonia >100 μmol/L requiring CRRT using veno‐venous HF . Arterial ammonia concentration and AC measured at 1 and 24 h after initiation of low (35 ml/kg/h) or high (90 ml/kg/h) filtration volume. Results: Twenty‐four patients (10 acute liver failure, 10 chronic liver disease and 4 following liver resection) were studied. Clearance of urea and ammonia solutes correlated closely ( r = 0.819, P = 0.007). Ammonia clearance correlated closely with ultrafiltration rate ( r = 0.86, P < 0.001). At 1 h, AC was 39 (34–54) ml/min (low volume) vs 85 (62–105) ml/min (high volume) CRRT , ( P < 0.001) and at 24 h 44 (34–63) vs 105 (82–109) ml/min, ( P = 0.01). Overall, a 22% reduction in median arterial ammonia concentration was observed over 24 h of HF from 156 (137–176) to 122 (85–133) μmol/L, ( P ≤ 0.0001). Conclusion: Clinically significant ammonia clearance can be achieved in adult patients with hyperammonaemia utilizing continuous VVHF . Ammonia clearance is closely correlated with ultrafiltration rate. HF was associated with a fall in arterial ammonia concentration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/liv.12221

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 178

Metadata

Authors
Slack, A. J., Auzinger, G., Willars, C., Dew, T., Musto, R., Corsilli, D., Sherwood, R., Wendon, J. A., & Bernal, W.
Venue
Liver International
Publisher
Wiley
Published
2013-06-20
Volume
34
Issue
1
Pages
42-48
ISSN
  • 0106-9543 (ISSN-L)
  • 1478-3223
  • 1478-3231
OpenAlex
W1973724823
Cited by
178
References
0
FWCI
5.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ammonia clearance with haemofiltration in adults with liver disease. https://app.cochat.ai/papers/10.1111/liv.12221
The paper
Slack, A. J., Auzinger, G., Willars, C., Dew, T., Musto, R., Corsilli, D., Sherwood, R., Wendon, J. A., & Bernal, W. (2014). Ammonia clearance with haemofiltration in adults with liver disease. Liver International. https://doi.org/10.1111/liv.12221

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.