Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 167

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Controlled attenuation parameter (CAP) for detection of hepatic steatosis in patients with chronic liver diseases: a prospective study of a native Korean population

Open access
Chon, Young Eun, Jung, Kyu Sik, Kim, Seung Up, Park, Jun Yong, Park, Young Nyun, Kim, Do Young, Ahn, Sang Hoon, Chon, Chae Yoon, Lee, Hye Won, Park, Yehyun, Han, Kwang‐Hyub·2014·Liver International

Abstract

Background: Controlled attenuation parameter (CAP) is a non‐invasive method of measuring hepatic steatosis using a process based on transient elastography. We investigated the diagnostic accuracy of CAP in detecting hepatic steatosis in patients with chronic liver disease (CLD). Methods: A total of 135 patients with CLD who underwent liver biopsy and CAP were consecutively enrolled in this prospective study. The performance of CAP for detection of hepatic steatosis compared with liver biopsy was calculated using area under receiver operating characteristics curves (AUROC). Steatosis was categorized into S0 (<5%), S1 (5–33%), S2 (34–66%) and S3 (>66% of hepatocytes). Results: Male gender predominated (n = 87, 64%) and the median age was 51 years. The aetiologies of CLD included non‐alcoholic fatty liver disease (n = 56, 41.5%) and chronic viral hepatitis because of hepatitis B (n = 47, 34.8%) and C (n = 12, 8.9%). Steatosis repartition was: S0 31.1% (n = 42), S1 43.7% (n = 59), S2 18.5% (n = 25) and S3 6.7% (n = 9) respectively. In the multivariate analysis, steatosis grade and body mass index were independently associated with CAP (all P < 0.001), whereas fibrosis stage and activity grade were not. The AUROC s of CAP were 0.885 for ≥S1 (sensitivity 73.1%, specificity 95.2%), 0.894 for ≥S2 (sensitivity 82.4%, specificity 86.1%) and 0.800 for S3 (sensitivity 77.8%, specificity 84.1%). The optimal cut‐off CAP values that maximized the Youden index were 250 dB/m (≥S1), 299 dB/m (≥S2), and 327 dB/m (=S3) respectively. Conclusions: Our data showed that CAP had high diagnostic accuracy for detecting hepatic steatosis in patients with CLD and suggested that CAP is also applicable for Asian patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/liv.12282

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 167

Metadata

Authors
Chon, Y. E., Jung, K. S., Kim, S. U., Park, J. Y., Park, Y. N., Kim, D. Y., Ahn, S. H., Chon, C. Y., Lee, H. W., Park, Y., & Han, K.
Venue
Liver International
Publisher
Wiley
Published
2013-09-13
Volume
34
Issue
1
Pages
102-109
ISSN
  • 0106-9543 (ISSN-L)
  • 1478-3223
  • 1478-3231
OpenAlex
W2149091051
Cited by
167
References
3
FWCI
9.30
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Controlled attenuation parameter (CAP) for detection of hepatic steatosis in patients with chronic liver diseases: a prospective study of a native Korean population. https://app.cochat.ai/papers/10.1111/liv.12282
The paper
Chon, Y. E., Jung, K. S., Kim, S. U., Park, J. Y., Park, Y. N., Kim, D. Y., Ahn, S. H., Chon, C. Y., Lee, H. W., Park, Y., & Han, K. (2014). Controlled attenuation parameter (CAP) for detection of hepatic steatosis in patients with chronic liver diseases: a prospective study of a native Korean population. Liver International. https://doi.org/10.1111/liv.12282

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.