The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Optimal threshold of controlled attenuation parameter with MRI‐PDFF as the gold standard for the detection of hepatic steatosis
Open accessAbstract
The optimal threshold of controlled attenuation parameter (CAP) for the detection of hepatic steatosis using both M and XL probe is unknown in nonalcoholic fatty liver disease (NAFLD). Magnetic resonance imaging proton density fat fraction (MRI‐PDFF) is an accurate and precise method of detecting the presence of hepatic steatosis that is superior to CAP. Thus, the aim of this study was to evaluate the diagnostic accuracy and optimal threshold of CAP for the detection of hepatic steatosis as defined by MRI‐PDFF ≥ 5%. This prospective cross‐sectional study included 119 adults (59% women) with and without NAFLD who underwent MRI‐PDFF and CAP using either M or XL probe when indicated within a 6‐month period at the NAFLD Research Center, University of California, San Diego. The mean ( ± standard deviation) age and body mass index were 52.4 (±15.2) years and 29.9 (±5.5) kg/m 2 , respectively. The prevalence of NAFLD (MRI‐PDFF ≥ 5%) and MRI‐PDFF ≥ 10% was 70.6% and 47.1%, respectively. The area under the receiver operating characteristic (AUROC) of CAP for the detection of MRI‐PDFF ≥ 5% was 0.80 (95% confidence interval [CI], 0.70‐0.90) at the cut‐point of 288 dB/m and of MRI‐PDFF ≥ 10% was 0.87 (95% CI, 0.80‐0.94) at the cut‐point of 306 dB/m. When stratified by the interquartile range (IQR) of CAP, we observed that an IQR below the median (30 dB/m) had a robust AUROC compared with an IQR above the median (0.92 [95% CI, 0.85‐1.00] versus 0.70 [95% CI, 0.56‐0.85]; P = 0.0117), and these differences were statistically and clinically significant. Conclusion : The cut‐point of CAP for presence of hepatic steatosis (MRI‐PDFF ≥ 5%) was 288 dB/m. The diagnostic accuracy of CAP for the detection of hepatic steatosis is more reliable when the IQR of CAP is <30 dB/m. These data have implications for the clinical use of CAP in the assessment of NAFLD. (H epatology 2018;67:1348‐1359)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856 · cited 2×
“The AUROC of CAP was compared using the method described by Hanley and McNeil.”
MethodYounossi, Z. M., Koenig, A. B., Abdelatif, D., Fazel, Y., Henry, L., & Wymer, M. (2016) · Hepatology · doi:10.1002/hep.28431 · Cited by 10,781
Hematological Problems in Pediatric Intensive Care
Revel-Vilk, S., Cox, P., Robitaille, N., & Blanchette, V. (2014) · Pediatric and Adolescent Medicine · doi:10.1159/000350346 · Cited by 3,508
Vernon, G., Baranova, A., & Younossi, Z. M. (2011) · Alimentary Pharmacology & Therapeutics · doi:10.1111/j.1365-2036.2011.04724.x · Cited by 3,074
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Neuschwander-Tetri, B. A., Loomba, R., Sanyal, A. J., Lavine, J. E., Van Natta, M. L., Abdelmalek, M. F., Chalasani, N., Dasarathy, S., Diehl, A. M., Hameed, B., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(14)61933-4 · Cited by 2,237
Self-citationWilliams, C. D., Stengel, J., Asike, M. I., Torres, D. M., Shaw, J., Contreras, M., Landt, C. L., & Harrison, S. A. (2011) · Gastroenterology · doi:10.1053/j.gastro.2010.09.038 · Cited by 2,148
The utility of radiological imaging in nonalcoholic fatty liver disease
Saadeh, S., Younossi, Z. M., Remer, E. M., Gramlich, T., Ong, J. P., Hurley, M., Mullen, K. D., Cooper, J. N., & Sheridan, M. J. (2002) · Gastroenterology · doi:10.1053/gast.2002.35354 · Cited by 2,110
Sampling Variability of Liver Biopsy in Nonalcoholic Fatty Liver Disease
Ratziu, V., Charlotte, F., Heurtier, A., Gombert, S., Giral, P., Bruckert, E., Grimaldi, A., Capron, F., & Poynard, T. (2005) · Gastroenterology · doi:10.1053/j.gastro.2005.03.084 · Cited by 2,106 · cited 1×
“Its accuracy has been questioned due to sampling errors and its interpretation and quantitative scoring is limited by significant inter- and intra-observer variability.((10-15)) In addition, liver biopsy is an expensive and invasive procedure which limits its use for the screening of population.”
BackgroundBravo, A. A., Sheth, S. G., & Chopra, S. (2001) · New England Journal of Medicine · doi:10.1056/nejm200102153440706 · Cited by 2,041
Cited by
Rinella, M. E., Neuschwander-Tetri, B. A., Siddiqui, M. S., Abdelmalek, M. F., Caldwell, S., Barb, D., Kleiner, D. E., & Loomba, R. (2023) · Hepatology · doi:10.1097/hep.0000000000000323 · Cited by 2,667
Self-citationBerzigotti, A., Tsochatzis, E., Boursier, J., Castera, L., Cazzagon, N., Friedrich-Rust, M., Petta, S., & Thiele, M. (2021) · Journal of Hepatology · doi:10.1016/j.jhep.2021.05.025 · Cited by 1,925
Noninvasive assessment of liver disease in patients with nonalcoholic fatty liver disease
Castera, L., Friedrich-Rust, M., & Loomba, R. (2019) · Gastroenterology · doi:10.1053/j.gastro.2018.12.036 · Cited by 1,494
Self-citationEddowes, P. J., Sasso, M., Allison, M., Tsochatzis, E., Anstee, Q. M., Sheridan, D., Guha, I. N., Cobbold, J. F., Deeks, J. J., Paradis, V., et al. (2019) · Gastroenterology · doi:10.1053/j.gastro.2019.01.042 · Cited by 1,410
Eslam, M., Sarin, S. K., Wong, V. W.-S., Fan, J.-G., Kawaguchi, T., Ahn, S. H., Zheng, M.-H., Shiha, G., Yilmaz, Y., Gani, R., et al. (2020) · Hepatology International · doi:10.1007/s12072-020-10094-2 · Cited by 833
Metadata
- Authors
- Caussy, C., Alquiraish, M. H., Nguyen, P., Hernandez, C., Cepin, S., Fortney, L. E., Ajmera, V., Bettencourt, R., Collier, S., Hooker, J., Sy, E., Rizo, E., Richards, L., Sirlin, C. B., & Loomba, R.
- Venue
- Hepatology
- Published
- 2018-02-19
- Volume
- 67
- Issue
- 4
- Pages
- 1348-1359
- ISSN
- 0270-9139 (ISSN-L)
- 1527-3350
- OpenAlex
- W2767268548
- Cited by
- 375
- References
- 53
- FWCI
- 16.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal threshold of controlled attenuation parameter with MRI‐PDFF as the gold standard for the detection of hepatic steatosis. https://app.cochat.ai/papers/10.1002/hep.29639
- The paper
- Caussy, C., Alquiraish, M. H., Nguyen, P., Hernandez, C., Cepin, S., Fortney, L. E., Ajmera, V., Bettencourt, R., Collier, S., Hooker, J., Sy, E., Rizo, E., Richards, L., Sirlin, C. B., & Loomba, R. (2018). Optimal threshold of controlled attenuation parameter with MRI‐PDFF as the gold standard for the detection of hepatic steatosis. Hepatology. https://doi.org/10.1002/hep.29639
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.