CoChat

Interobserver variability in transient elastography analysis of patients with chronic hepatitis C

Open access
Perazzo, Hugo, Fernandes, Flavia F., Gomes, Amanda, Terra, Carlos, Perez, Renata M., Figueiredo, Fátima A. F. · 2015 · Liver International
Cited by 38

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background & Aims: Transient elastography based on liver stiffness measurement is a non‐invasive method to assess hepatic fibrosis. However, interobserver variability has led to controversy over its use in fibrosis evaluation. To evaluate the interobserver variation in transient elastography in chronic hepatitis C. Methods: We performed a cross‐sectional study, analysing findings from two experienced operators who each assessed 195 patients by transient elastography on the same day. Liver stiffness measurement used to define fibrosis stages, based on METAVIR score, was: <7.1 as F0F1, 7.1–9.4 as F2, 9.5–12.4, as F3 and >12.4 kPa as F4. We also assessed interobserver variation in identification of potential oesophageal varices screening based on transient elastography. Results: The interobserver intraclass correlation coefficient was 0.940 (95% CI 0.863–0.967) and measurements made by operators correlated [Spearman's ρ = 0.924; P < 0.001]. However, the median liver stiffness measurement assessed by first operators was higher (11.5 vs 9.8 kPa; P < 0.001). The discordance between operators was 35% for at least one stage of fibrosis and 5% for two or more stages. Interobserver reliability values were κ = 0.61 for fibrosis stages F ≥ 2 and κ = 0.80 for cirrhosis. Among the 74 patients determined to have cirrhosis by at least one operator, there was considerable discordance in identification of those with indication for oesophageal varices screening (κ values from 0.13 to 0.61) according to several cut‐offs. Conclusion: Although a high correlation of liver stiffness measurement between operators, interobserver variability in transient elastography was not negligible. This method should not be used as the only screening tool for oesophageal varices in chronic hepatitis C.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/liv.12551

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 38

Metadata

Authors
Perazzo, H., Fernandes, F. F., Gomes, A., Terra, C., Perez, R. M., & Figueiredo, F. A. F.
Venue
Liver International
Publisher
Wiley
Published
2014-04-15
Volume
35
Issue
5
Pages
1533-1539
ISSN
  • 0106-9543 (ISSN-L)
  • 1478-3223
  • 1478-3231
OpenAlex
W2040001513
Cited by
38
References
1
FWCI
4.04
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Interobserver variability in transient elastography analysis of patients with chronic hepatitis C. https://app.cochat.ai/papers/10.1111/liv.12551
The paper
Perazzo, H., Fernandes, F. F., Gomes, A., Terra, C., Perez, R. M., & Figueiredo, F. A. F. (2015). Interobserver variability in transient elastography analysis of patients with chronic hepatitis C. Liver International. https://doi.org/10.1111/liv.12551

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.