Implanted high density cuff electrodes functionally activate human tibial and peroneal motor units without chronic detriment to peripheral nerve health
Abstract
Objective Peripheral nerve stimulation via multi-contact nerve cuff electrodes (NCEs) has proved effective in restoring function to individuals with lower-extremity paralysis. This study investigates clinical measures of nerve health over one year post-implantation of a composite flat-interface nerve electrode (C-FINE) on the tibial and peroneal nerves above the knee in a human volunteer. This represents the first deployment of a novel NCE on new neural targets in a uniquely challenging location prone to prolonged externally applied forces, making acute and chronic postoperative observation critical.Materials and methods A 27-year-old man with an incomplete spinal cord injury (AIS C) at the C3 to C4 level received eight-contact C-FINEs bilaterally on the tibial and peroneal nerves, proximal to the knee. Access to four contacts per cuff exhibiting the most desirable responses was externalized via temporary percutaneous leads. Percutaneous leads were later removed, with contacts generating the best dorsiflexion (two of four) and plantar flexion (one of four) reconnected to a permanently implanted pulse generator. For 13 months post-implantation, nerve health and cuff performance were assessed through motor nerve conduction velocity (MNCV) studies, clinical needle electromyography, compound motor action potential (CMAP), sensory nerve action potential (SNAP), stimulation-evoked tetanic moment collection, and lower-limb circumference measurements.Results Tibial and peroneal MNCVs remained stable bilaterally above 40 m/sec, with CMAPs increased or stable after six months. SNAPs remained stable across all measurements. CMAP initial charge thresholds remained below 50 nC, with minimal changes to muscle recruitment order in three of four externalized contacts per cuff. Peak tetanic moments remained stable, with bilateral increases in thigh and calf circumferences of 5% and 14% over one year.Conclusions Above-knee tibial and peroneal NCEs can restore stimulated ankle-joint function without chronic nerve health detriments. Alongside previous femoral nerve data, this study demonstrates the ability of NCEs to enhance lower-extremity function with limited neuromuscular impact.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Extraneural electrodes are generally simple to implant and have shown selective stimulation in multiple long-term clinical trials for motor and sensory restoration.
“Although they require the nerve to be freed from the surrounding tissues, extraneural electrodes are generally simple to implant [15] and have shown selective stimulation in multiple long-term clinical trials for motor and sensory restoration [16-18].”
From Directed stimulation with interfascicular interfaces for peripheral nerve stimulation (2021) · cites this paper as [16]
The citation lists haven’t been fetched yet
References 28 · Cited by 20
- Authors
- Delianides, C., Tyler, D., Pinault, G., Ansari, R., & Triolo, R.
- Affiliations
- Case Western Reserve University (US)
- Louis Stokes Cleveland VA Medical Center (US)
- Corresponding author
- Triolo, Ronald
- Venue
- Neuromodulation Technology at the Neural Interface
- Publisher
- Elsevier BV
- Published
- 2020-08
- Volume
- 23
- Issue
- 6
- Pages
- 754-762
- ISSN
- 1094-7159 (ISSN-L)
- OpenAlex
- W3011788924
- Cited by
- 20
- References
- 28
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 3 · 2023: 3 · 2022: 2 · 2021: 6 · 2020: 2
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Neuromodulation Technology at the Neural Interface (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (R01 EB01899)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Pathology and Forensic Medicine › Spinal Cord Injury Research
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- cuff electrodes, peripheral nerve stimulation, tibial nerve, peroneal nerve, incomplete spinal cord injury, paraplegia, ankle function, motor nerve conduction velocity, compound motor action potential, sensory nerve action potential, muscle atrophy, neuromodulation
- MeSH terms
- Adult, Electrodes, Implanted, Electromyography, Femoral Nerve, Humans, Knee, Male, Peroneal Nerve, Spinal Cord Injuries, Tibial Nerve
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review