CoChat

Anorectal pressures measured with high‐resolution manometry in healthy people—Normal values and asymptomatic pelvic floor dysfunction

Open access
Oblizajek, Nicholas R., Gandhi, Sangeetha, Sharma, Mayank, Chakraborty, Subhankar, Muthyala, Anjani, Prichard, David, Feuerhak, Kelly, Bharucha, Adil E. · 2019 · Neurogastroenterology & Motility
Cited by 101

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: High‐resolution manometry (HRM) is used to measure rectoanal pressures in defecatory disorders and fecal incontinence. This study sought to define normal values for rectoanal HRM, ascertain the effects of age and BMI on rectoanal pressures, and compare pressures in asymptomatic women with normal and prolonged balloon expulsion time (BET). Methods: High‐resolution manometry pressures and BET were measured in 163 asymptomatic healthy participants. Women (96) and men (47) with normal BET were used to estimate normal values and the effects of age/BMI on pressures using a Medtronic 4.2‐mm‐diameter rectoanal catheter. Key Results: Age is associated with lower resting pressure, higher rectal pressure during evacuation, and a higher rectoanal gradient during evacuation in women and men. In women, the BET is also inversely correlated with age while the BMI is correlated with a higher threshold volume for discomfort and a longer BET. The anal squeeze pressure increment, squeeze duration, and HPZ length are higher in men than women. The rectoanal gradient during evacuation is also lower (ie, more negative) in asymptomatic women with an abnormal than a normal BET. Conclusions & Inferences: These findings provide an expanded database of normal values for anorectal HRM in men and women. Age and sex affect anal resting and squeeze pressures, respectively; rectal pressure during evacuation is also higher in older people. Less than 15% of asymptomatic people have BET >60 seconds, which is associated with manometry features of impaired evacuation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/nmo.13597

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 101

Metadata

Authors
Oblizajek, N. R., Gandhi, S., Sharma, M., Chakraborty, S., Muthyala, A., Prichard, D., Feuerhak, K., & Bharucha, A. E.
Venue
Neurogastroenterology & Motility
Publisher
Wiley
Published
2019-04-08
Volume
31
Issue
7
Pages
e13597-e13597
ISSN
  • 1350-1925 (ISSN-L)
  • 1365-2982
OpenAlex
W2936108127
Cited by
101
References
1
FWCI
7.04
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Anorectal pressures measured with high‐resolution manometry in healthy people—Normal values and asymptomatic pelvic floor dysfunction. https://app.cochat.ai/papers/10.1111/nmo.13597
The paper
Oblizajek, N. R., Gandhi, S., Sharma, M., Chakraborty, S., Muthyala, A., Prichard, D., Feuerhak, K., & Bharucha, A. E. (2019). Anorectal pressures measured with high‐resolution manometry in healthy people—Normal values and asymptomatic pelvic floor dysfunction. Neurogastroenterology & Motility. https://doi.org/10.1111/nmo.13597

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.