The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Statistical guidelines for the analysis of data obtained from one or both eyes
Open accessAbstract
Purpose: Measurements obtained from the right and left eye of a subject are often correlated whereas many statistical tests assume observations in a sample are independent. Hence, data collected from both eyes cannot be combined without taking this correlation into account. Current practice is reviewed with reference to articles published in three optometry journals, viz., O phthalmic and P hysiological O ptics ( OPO ), O ptometry and V ision S cience ( OVS ), C linical and E xperimental O ptometry ( CEO ) during the period 2009–2012. Recent findings: Of the 230 articles reviewed, 148/230 (64%) obtained data from one eye and 82/230 (36%) from both eyes. Of the 148 one‐eye articles, the right eye, left eye, a randomly selected eye, the better eye, the worse or diseased eye, or the dominant eye were all used as selection criteria. Of the 82 two‐eye articles, the analysis utilized data from: (1) one eye only rejecting data from the adjacent eye, (2) both eyes separately, (3) both eyes taking into account the correlation between eyes, or (4) both eyes using one eye as a treated or diseased eye, the other acting as a control. In a proportion of studies, data were combined from both eyes without correction. Summary: It is suggested that: (1) investigators should consider whether it is advantageous to collect data from both eyes, (2) if one eye is studied and both are eligible, then it should be chosen at random, and (3) two‐eye data can be analysed incorporating eyes as a ‘within subjects’ factor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical Methods for Rates and Proportions
Fleiss, J. L., Levin, B., & Paik, M. C. (2003) · Wiley Series in Probability and Statistics · doi:10.1002/0471445428 · Cited by 18,646
Forming inferences about some intraclass correlation coefficients.
McGraw, K. O., & Wong, S. P. (1996) · Psychological Methods · doi:10.1037/1082-989x.1.1.30 · Cited by 6,903
Cornell, J. A. (2012) · Technometrics · Cited by 743
A critical discussion of intraclass correlation coefficients
Müller, R., & Büttner, P. (1994) · Statistics in Medicine · doi:10.1002/sim.4780132310 · Cited by 714
Statistics Notes: Measurement error and correlation coefficients
Bland, J. M., & Altman, D. G. (1996) · BMJ · doi:10.1136/bmj.313.7048.41 · Cited by 639
The Wilcoxon signed rank test for paired comparisons of clustered data
Rosner, B., Glynn, R. J., & Lee, M. T. (2006) · Biometrics · doi:10.1111/j.1541-0420.2005.00389.x · Cited by 557
McAlinden, C., Khadka, J., & Pesudovs, K. (2011) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2011.00851.x · Cited by 436
People and eyes: statistical approaches in ophthalmology
MURDOCH, I. E., MORRIS, S. S., & COUSENS, S. N. (1998) · British Journal of Ophthalmology · doi:10.1136/bjo.82.8.971 · Cited by 322
Statistical Methods in Ophthalmology: An Adjustment for the Intraclass Correlation between Eyes
ROSNER, B. A. (1982) · Biometrics · doi:10.2307/2530293 · Cited by 291
Donner, A. (1986) · International Statistical Review / Revue Internationale de Statistique · doi:10.2307/1403259 · Cited by 291
Multivariate Methods in Ophthalmology with Application to Other Paired-Data Situations
Rosner, B. (1984) · Biometrics · doi:10.2307/2531153 · Cited by 265
Incorporation of Clustering Effects for the Wilcoxon Rank Sum Test: A Large‐Sample Approach
Rosner, B., Glynn, R. J., & Ting Lee, M. (2003) · Biometrics · doi:10.1111/j.0006-341x.2003.00125.x · Cited by 218
Clinical evaluation of the Grand Seiko Auto Ref/Keratometer WAM-5500
Sheppard, A. L., & Davies, L. N. (2010) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2009.00701.x · Cited by 199
The application of analysis of variance ( ANOVA ) to different experimental designs in optometry
Armstrong, R. A., Eperjesi, F., & Gilmartin, B. (2002) · Ophthalmic and Physiological Optics · doi:10.1046/j.1475-1313.2002.00020.x · Cited by 172
Self-citationPrism Therapy and Visual Rehabilitation in Homonymous Visual Field Loss
O’Neill, E. C., Connell, P., O'Connor, J. C., Brady, J., Reid, I., & Logan, P. (2011) · Optometry and Vision Science · doi:10.1097/opx.0b013e318205a3b8 · Cited by 155
Accounting for the Correlation Between Fellow Eyes in Regression Analysis
Glynn, R. J., & Rosner, B. (1992) · Archives of Ophthalmology · doi:10.1001/archopht.1992.01080150079033 · Cited by 152
Choice of Analytic Approach for Eye-Specific Outcomes: One Eye or Two?
Karakosta, A., Vassilaki, M. E., Plainis, S., Elfadl, N. H., Tsilimbaris, M. K., & Moschandreas, J. A. (2011) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2011.08.032 · Cited by 133
Statistical guidelines for clinical studies of human vision
Armstrong, R. A., Davies, L. N., Dunne, M. C. M., & Gilmartin, B. (2011) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2010.00815.x · Cited by 124
Self-citationThe Importance of Accounting for Correlated Observations
Sainani, K. L. (2010) · PM&R · doi:10.1016/j.pmrj.2010.07.482 · Cited by 114
Reliability and repeatability of the Pentacam on corneal curvatures
Chen, D., & Lam, A. K. C. (2009) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2008.00336.x · Cited by 106
An exploratory study of visual search performance in glaucoma
Smith, N. D., Crabb, D. P., & Garway‐Heath, D. F. (2011) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2011.00836.x · Cited by 79
Black, A. A., Wood, J. M., & Lovie‐Kitchin, J. E. (2011) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2010.00811.x · Cited by 69
Syed, A., Armstrong, R. A., & Smith, C. U. M. (2005) · PubMed · Cited by 40
Self-citationShort-wavelength automated perimetry in patients with migraine
Yenice, Ö., Temel, A., Incili, B., & Tuncer, N. (2005) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-005-0083-7 · Cited by 28
Tajbakhsh, Z., Salouti, R., Nowroozzadeh, M. H., Mohammad, A. A., Tabatabaee, S., & Zamani, M. (2012) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2012.00942.x · Cited by 27
Structure and Function in Patients with Glaucomatous Defects Near Fixation
Shafi, A., Swanson, W. H., & Dul, M. W. (2010) · Optometry and Vision Science · doi:10.1097/opx.0b013e3181fa38f4 · Cited by 20
Macular Pigment: Its Associations with Color Discrimination and Matching
Davison, P. A., Akkali, M. C., Loughman, J., Scanlon, G., Nolan, J. M., & Beatty, S. (2011) · Optometry and Vision Science · doi:10.1097/opx.0b013e31821798ec · Cited by 15
Intra‐observer repeatability of optical quality measures provided by a double‐pass system
Tomás, J., Pinero, D. P., & ALIO, J. L. (2011) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2011.00660.x · Cited by 13
Oculometric parameters of hyperopia in children with esotropic amblyopia
Debert, I., de Alencar, L. M., Polati, M., Souza, M. B., & Alves, M. R. (2011) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2011.00850.x · Cited by 12
Slade, S. V., Dunne, M. C. M., & Miles, J. N. V. (2002) · Ophthalmic and Physiological Optics · doi:10.1046/j.1475-1313.2002.00007.x · Cited by 11
Constancy of the Orbscan acoustic factor to detect contact lens‐induced corneal swelling
Martín, R., Nunez, L. A. O., Sastre, J., de Juan, V., & Rodríguez, G. (2011) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2010.00578.x · Cited by 10
Ogbuehi, K. C., Mucke, S., & Osuagwu, U. L. (2012) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2012.00945.x · Cited by 9
Hon, Y., Cheung, S. W., Cho, P., & Lam, A. K. C. (2012) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2012.00920.x · Cited by 8
ROSNER, B. A., Glynn, R. J., & Lee, M. T. (2007) · Ophthalmic Epidemiology · doi:10.1080/09286580701396704 · Cited by 6
Cited by
Graefe's Archive for Clinical and Experimental Ophthalmology
(2013) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/417.1435-702x · Cited by 399
Protocols for Studies of Intraocular Lens Formula Accuracy
Hoffer, K. J., Aramberri, J., Haigis, W., Olsen, T., Savini, G., Shammas, H. J., & Bentow, S. (2015) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2015.05.029 · Cited by 280
Metadata
- Authors
- Armstrong, R. A.
- Venue
- Ophthalmic and Physiological Optics
- Published
- 2012-12-17
- Volume
- 33
- Issue
- 1
- Pages
- 7-14
- ISSN
- 0275-5408 (ISSN-L)
- 1475-1313
- OpenAlex
- W2005859915
- Cited by
- 522
- References
- 35
- FWCI
- 12.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.