Should Pearson's correlation coefficient be avoided?
The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Purpose: To survey the use of Pearson's correlation coefficient ( r ) and related statistical methods in the ophthalmic literature, to consider the limitations of r , and to suggest suitable alternative methods of analysis. Recent findings: Searching Ophthalmic and Physiological Optics ( OPO ), Optometry and Vision Science ( OVS ), and Clinical and Experimental Optometry ( CXO ) online archives using correlation and Pearson's r as search terms resulted in 4057 and 281 hits respectively. C oefficient of determination , r square , or r squared received fewer hits (65, 8, and 22 hits respectively). The assumption that r follows a bivariate normal distribution was rarely encountered (3 hits) although several studies applied Spearman's rank correlation (70 hits). The intra‐class correlation coefficient ( ICC ) was widely used (178 hits), but fewer hits were recorded for partial correlation (43 hits) and multiple correlation (13) hits. There was little evidence that the problem of sample size was addressed in correlation studies. Summary: Investigators should be alert to whether: (1) the relationship between two variables could be non‐linear, (2) the data are bivariate normal, (3) r accounts for a significant proportion of the variance in Y , (4) outliers are present, the data are clustered, or have a restricted range, (5) the sample size is appropriate, and (6) a significant correlation indicates causality. In addition, the number of significant digits used to express r and the problems of multiple testing should be addressed. The problems and limitations of r suggest a more cautious approach regarding its use and the application of alternative methods where appropriate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Forming inferences about some intraclass correlation coefficients.
McGraw, K. O., & Wong, S. P. (1996) · Psychological Methods · doi:10.1037/1082-989x.1.1.30 · Cited by 6,903 · cited 1×
“52,53 The main difference between the ICC and conventional r is that all data are pooled to estimate the mean and variance of the ICC and unlike r the ICC is not sensitive to range restriction.”
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Fundamental Statistics in Psychology and Education.
Smith, B. B., & Guilford, J. P. (1951) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2980908 · Cited by 3,455
When to use the Bonferroni correction
Armstrong, R. A. (2014) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12131 · Cited by 3,031 · cited 1×
“If it is essential to examine the simple correlations among many variables then the advice remains the same as discussed previously.(68) Hence, correction may be relevant in situations where an investigator is searching for significant correlations but without a pre-established hypothesis.”
Self-citationMeasures of Association for Cross Classifications
Goodman, L. A., & Kruskal, W. H. (1979) · Springer Series in Statistics · doi:10.1007/978-1-4612-9995-0 · Cited by 2,244
Biostatistics : The Bare Essentials
Norman, G. R., & Streiner, D. L. (1993) · Cited by 1,482
Fundamental Statistics in Psychology and Education.
(1966) · Contemporary Psychology: A Journal of Reviews · doi:10.1037/008080 · Cited by 991
Cornell, J. A. (2012) · Technometrics · Cited by 743
Measures of Association for Cross Classifications*
Goodman, L. A., & Kruskal, W. H. (1954) · Journal of the American Statistical Association · doi:10.1080/01621459.1954.10501231 · Cited by 678
Statistics Notes: Measurement error and correlation coefficients
Bland, J. M., & Altman, D. G. (1996) · BMJ · doi:10.1136/bmj.313.7048.41 · Cited by 639
Statistical guidelines for the analysis of data obtained from one or both eyes
Armstrong, R. A. (2013) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12009 · Cited by 522
Self-citationMcAlinden, C., Khadka, J., & Pesudovs, K. (2011) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2011.00851.x · Cited by 436 · cited 1×
“Nevertheless, some studies have used r as a measure of correlation in test/retest studies(58) or use it in combination with ICC(59) but this use of r should be avoided.(60) Hence, the ICC is a useful adjunct to a Bland and Altman plot as a relative measure of the degree of consistency of measurements made by two metho…”
Robust estimation and outlier detection with correlation coefficients
DEVLIN, S. J., GNANADESIKAN, R., & KETTENRING, J. R. (1975) · Biometrika · doi:10.1093/biomet/62.3.531 · Cited by 397
Rubin, G. S., West, S. K., Muñoz, B., Bandeen‐Roche, K., Zeger, S. L., Schein, O. D., & Fried, L. P. (1997) · PubMed · Cited by 387
ON THE LAWS OF INHERITANCE IN MAN: I. INHERITANCE OF PHYSICAL CHARACTERS
Pearson, K., & Lee, A. M. (1903) · Biometrika · doi:10.1093/biomet/2.4.357 · Cited by 362 · cited 1×
“Testing the degree of correlation between two or more variables is one of the most widely used of all statistical procedures(1); the product moment correlation coefficient, also known as Pearson’s correlation coefficient (r) being one of the most frequently used statistics.(2) In ophthalmic research, correlation metho…”
Kumar, K. (2011) · Journal of the Royal Statistical Society Series A: Statistics in Society · doi:10.1111/j.1467-985x.2010.00676_4.x · Cited by 340
Visual Impairment and Disability in Older Adults
Rubin, G. S., Roche, K. B., PRASADA-RAO, P., & Fried, L. P. (1994) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1994.tb03438.x · Cited by 318
The reliability of the Pelli-Robson contrast sensitivity chart
Elliott, D. (1990) · Ophthalmic and Physiological Optics · doi:10.1016/0275-5408(90)90124-h · Cited by 272
Statistical guidelines for clinical studies of human vision
Armstrong, R. A., Davies, L. N., Dunne, M. C. M., & Gilmartin, B. (2011) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2010.00815.x · Cited by 145
Self-citationRelationship between age and intraocular pressure: the Blue Mountains Eye Study
Rochtchina, E., Mitchell, P., & Wang, J. J. (2002) · Clinical and Experimental Ophthalmology · doi:10.1046/j.1442-9071.2002.00519.x · Cited by 130 · cited 1×
“For example, in the study of Rochtchina et al.(61) the data suggested a positive correlation between IOP and age.”
Armstrong, R. A., Slade, S. V., & Eperjesi, F. (2000) · Ophthalmic and Physiological Optics · doi:10.1016/s0275-5408(99)00064-2 · Cited by 104
Self-citationAdult Age Differences in Visual Acuity, Stereopsis, and Contrast Sensitivity
Greene, H. A., & Madden, D. J. (1987) · Optometry and Vision Science · doi:10.1097/00006324-198710000-00006 · Cited by 94
The Relation Between Visual Acuity and Other Spatial Vision Measures
Hægerström-Portnoy, G., Schneck, M. E., Lott, L. A., & BRABYN, A. J. A. (2000) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2000.tb01158.x · Cited by 83
A comparison of two approaches to correction of restriction of range in correlation analysis
Wiberg, M., & Sundström, A. (2009) · University of Massachusetts Amherst · doi:10.7275/as0k-tm88 · Cited by 72 · cited 1×
“44 Formulae for adjusting r values for ‘range restric-tion’ are available and if the data come from a bivariate normal distribution the methods described by Guilford, 45 Thorndike, 46 and Wiberg and Sondstrom, 47 the latter being based on a ‘missing value’ approach, have been used.”
Clinical contrast sensitivity chart evaluation
Elliott, D. B., & Whitaker, D. (1992) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.1992.tb00397.x · Cited by 72
Prevalence of myopia and hyperopia in a population of Polish schoolchildren
Czepita, D., Żejmo, M., & Mojsa, A. (2006) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2006.00419.x · Cited by 72 · cited 1×
“If 10–12 Kendall’s rank correlation ( s ), which like Spearman’s r s can be used as a measure of an ability to appraise or detect a property by scoring, has been more rarely applied.”
Evaluation of Reading Speed and Contrast Sensitivity in Dry Eye Disease
Ridder, W. H., Zhang, Y., & Huang, J.-F. (2012) · Optometry and Vision Science · doi:10.1097/opx.0b013e3182780dbb · Cited by 57
RELIABILITY AND SENSITIVITY OF CLINICAL CONTRAST SENSITIVITY TESTS
Rubin, G. S. (1988) · UCL Discovery (University College London) · Cited by 57
Relationship between intraocular pressure and systemic health parameters in the Korean population
Lee, J. S., Choi, Y. R., Lee, J. E., Choi, H. Y., Lee, S. H., & Oum, B. S. (2002) · Korean Journal of Ophthalmology · doi:10.3341/kjo.2002.16.1.13 · Cited by 48
Corneal biomechanical properties measured with the Ocular Response Analyser in a myopic population
Plakitsi, A., O’Donnell, C., Miranda, M. A., Charman, W. N., & Radhakrishnan, H. (2011) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2011.00852.x · Cited by 48 · cited 1×
“17 in their study of the correlation of refractive error among right and left eyes and between corneal hysteresis and corneal resistance factor respectively and by Grosvenor and Rolene 18 in their study of axial length/corneal radius as a function of spherical equivalent refraction ( r 2 = 84%).”
León, A., Medrano, S. M., & Rosenfield, M. (2012) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2012.00891.x · Cited by 47 · cited 1×
“In addition, ICC has been used to study repeatability in studies of the Corvis ST ‘air puff’ intraocular pressure measurement,(55) between various measures of subjective refraction,(56) and dynamic microscopy and subjective measurements of amplitude of accommodation.(57) Nevertheless, some studies have used r as a mea…”
Statistical Analysis in Microbiology: Statnotes
Armstrong, R. A., & Hilton, A. C. (2010) · Wiley eBooks · doi:10.1002/9780470905173 · Cited by 47
Self-citationIs there a large sample size problem?
Armstrong, R. A. (2019) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12618 · Cited by 47 · cited 2×
“22 4.”
Self-citationWatanabe, S., Yamashita, T., & Ohba, N. (1999) · Ophthalmic and Physiological Optics · doi:10.1046/j.1475-1313.1999.00406.x · Cited by 43
The Perceived Bulbar Redness of Clinical Grading Scales
Schulze, M., Hutchings, N., & SIMPSON, T. L. (2009) · Optometry and Vision Science · doi:10.1097/opx.0b013e3181bb4225 · Cited by 34 · cited 1×
“…contrast sensitivity in dry eye disease controlling for differences in age among groups, 63 the perceived bulbar redness of clinical grading scales, 64 and to investigate the relationship between refractive error (spherical equivalent) and visual acuity accounting for the DM/DD ratio and the…”
Visual acuity and contrast sensitivity in the elderly
Hirvelä, H., Koskela, P. U., & Laatikainen, L. (1995) · Acta Ophthalmologica Scandinavica · doi:10.1111/j.1600-0420.1995.tb00648.x · Cited by 31 · cited 1×
“37 When r is high it was concluded that other measures of spatial vision added no further information 38 whereas when r is low, several different dimensions of vision were being assessed.”
Random Word Recognition Chart Helps Scotoma Assessment in Low Vision
MacKeben, M., Nair, U. K. W., Walker, L. L., & Fletcher, D. C. (2015) · Optometry and Vision Science · doi:10.1097/opx.0000000000000548 · Cited by 31
Decimal Dust, Significant Digits, and the Search for Stars
Bedeian, A. G., Sturman, M. C., & Streiner, D. L. (2008) · Organizational Research Methods · doi:10.1177/1094428108321153 · Cited by 26 · cited 2×
“66 carried out simulations to investigate the precision of simple correlations.”
The use of correlation and regression methods in optometry
Armstrong, R. A., Eperjesi, F., & Gilmartin, B. (2005) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2005.tb06672.x · Cited by 21 · cited 1×
“, how much of the variation in standard visual acuity can be explained by other spatial vision measures(3) and fourth, to test the goodness of fit of a linear regression.(1) In addition, several related statistical methods have been commonly applied including partial and multiple correlation coefficients and the famil…”
Self-citationResearch Problems and Techniques: Report No. 3
Thorndike, R. L. (1947) · PsycEXTRA Dataset · doi:10.1037/e659562007-001 · Cited by 20
Retinal measurements using time domain OCT imaging before and after myopic Lasik
Lei, F., Burns, S. A., Shao, L., & Yang, Y. (2012) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2012.00905.x · Cited by 19 · cited 1×
“28–30 Hence, in the data illustrated in Figure 1 , changing the final point (63, 21.2) to (63,10) would have a dramatic effect on r reducing it from r = 0.81 to r = 0.23.”
InfluentialLam, A. K. C., Chan, R., Woo, G. C., Pang, P. C. K., & Chiu, R. (2002) · Ophthalmic and Physiological Optics · doi:10.1046/j.1475-1313.2002.00074.x · Cited by 18 · cited 1×
“Lam et al.(54) examined the degree of intra-observer and interobserver repeatability of anterior eye segment analysis system (EAS-1000) using the ICC and found good levels of repeatability.”
Jorge, J., González‐Méijome, J. M., Queirós, A., Fernandes, P. R. B., & Diaz‐Rey, J. A. (2011) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2010.00817.x · Cited by 14
Relationship between Corneal Thickness and Radius to Body Height
Jonuscheit, S., Doughty, M. J., Martín, R., & Río‐Cristóbal, A. (2017) · Optometry and Vision Science · doi:10.1097/opx.0000000000001034 · Cited by 13 · cited 1×
“Jonuscheit et al.(16) found that body height was weakly associated with central corneal thickness and peripheral corneal thickness (r ≥ 0.”
Comparing LEA Numbers Low Vision Book and Feinbloom Visual Acuity Charts
Hardgrave, N., Hatley, J., & Lewerenz, D. (2012) · Optometry and Vision Science · doi:10.1097/opx.0b013e31826ab10a · Cited by 6 · cited 11×
“Search terms were divided into several groups, i.e., those relevant to: (1) correlation generally ( correlation , correlation coefficient ), (2) correlation more specifically ( Pearson’s correlation coefficient , Pearson r , pro-duct-moment correlation coefficient , (3) the interpretation of r ( coefficient of determinatio…”
InfluentialFactors Accounting for the 4‐Year Change in Acuity in Patients Between 50 and 80 Years
Koenig, D. E., Nguyen, L. C., Parker, K. E., & Applegate, R. A. (2013) · Optometry and Vision Science · doi:10.1097/opx.0b013e318296ac4d · Cited by 3 · cited 1×
“Koenig et al.(20) studied the effect of various metrics on changes in logMAR and reported r(2) values in the range 3–21%.”
Cited by
Physical-aware model accuracy estimation for protein complex using deep learning method
Wang, H., Sun, M., Xie, L., Liu, D., & Zhang, G. (2025) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2025.01.017 · Cited by 5
“Specifically, we use Pearson [43] and Spearman [44] metrics to measure the correlation between the predicted lDDT score of interface residues and the true lDDT, focusing on evaluating the accuracy of the methods in ranking the models.”
Metadata
- Authors
- Armstrong, R. A.
- Venue
- Ophthalmic and Physiological Optics
- Published
- 2019-08-18
- Volume
- 39
- Issue
- 5
- Pages
- 316-327
- ISSN
- 0275-5408 (ISSN-L)
- 1475-1313
- OpenAlex
- W2969295906
- Cited by
- 192
- References
- 48
- FWCI
- 9.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.