Translating glycated hemoglobin A1c into time spent in glucose target range: A multicenter study
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Background Approximately 90% of children and adolescents with type 1 diabetes in Sweden use continuous glucose monitoring (CGM), either as real-time CGM or intermittently scanned CGM to monitor their glucose levels. Time in target range (TIT) is an easily understandable metric for assessing glycemic control. Objective The aim of this study was to examine the relation between TIT and hemoglobin A1c (HbA1c). Subjects and Methods Subjects were recruited from three diabetes care centers in Sweden. Glucose data were collected for 133 children and adolescents with type 1 diabetes through CGM using Diasend. Subjects with registration time over 80% were included in the analysis. HbA1c was collected from SWEDIABKIDS, the Swedish pediatric diabetes quality registry. TIT was defined as 3.9 to 7.8 mmol/L (70-140 mg/dL) and time in range (TIR) as 3.9 to 10 mmol/L (70-180 mg/dL). Results During the period of 60 days, 105 subjects provided complete data for analysis. Mean age was 12.2 (±3.3) years, mean HbA1c was 53.9 (±8.2) mmol/mol or 7.1% (±0.7%). Mean sensor glucose value was 8.6 (±1.3) mmol/L, mean coefficient of variation was 42.2% (±7.2%), mean TIT was 40.9% (±SD 12.2%), and mean TIR was 60.8% (±13.1%). There was a significant nonlinear relation between TIT during 60 days and HbA1c, R2 = 0.69. Conclusion This study suggests a nonlinear relation between time spent in glucose target range and HbA1c. The finding implies that time spent in TIT could be a useful metric in addition to HbA1c to assess glycemic control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069 · cited 2×
“CV less than 36% was categorized as a stable glucose level.(5) HbA1c was measured at the outpatient visit with either of the two equivalent methods DC-2000 (Siemens/Bayer, Erlangen, Germany) or DCA Vantage (Siemens Healthineers, Erlangen, Germany), standardized in accordance with Equalis.”
MethodTranslating the A1C assay into estimated average glucose values
Nathan, D. M., Kuenen, J., Borg, R., Zheng, H., Schoenfeld, D., Heine, R. J., & for the A1c-Derived Average Glucose (ADAG) Study Group (2008) · Diabetes Care · doi:10.2337/dc08-0545 · Cited by 1,812
Significance of HbA1c Test in Diagnosis and Prognosis of Diabetic Patients
Sherwani, S. I., Khan, H. A., Ekhzaimy, A., Masood, A., & Sakharkar, M. K. (2016) · Biomarker Insights · doi:10.4137/bmi.s38440 · Cited by 1,381
Reichard, P., Nilsson, B.-Y., & Rosenqvist, U. (1993) · New England Journal of Medicine · doi:10.1056/nejm199307293290502 · Cited by 1,202 · cited 2×
“Higher HbA1c, used as a marker of hyperglycemia, has also been linked to increased risk of micro-and macrovascular diabetes complications.(2,3) CGM provides an abundance of glycemic data, and there is a need to explore how these data correlate with classical risk markers such as HbA1c.”
Backgroundthe SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494
Wheeler, E., Leong, A., Liu, C.-T., Hivert, M.-F., Strawbridge, R. J., Podmore, C., Li, M., Yao, J., Sim, X., Hong, J., et al. (2017) · PLOS Medicine · doi:10.1371/journal.pmed.1002383 · Cited by 408
Agiostratidou, G., Anhalt, H., Ball, D., Blonde, L., Gourgari, E., Harriman, K. N., Kowalski, A. J., Madden, P., McAuliffe-Fogarty, A. H., McElwee-Malloy, M., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1624 · Cited by 397
Cited by
14. Children and Adolescents: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s014 · Cited by 367
13. Children and Adolescents: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s013 · Cited by 223
“While studies indicate a relation between time in range and A1C (105,106), it is still uncertain what the ideal target time in range should be for children, and further studies are needed.”
Background14. Children and Adolescents: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s014 · Cited by 173
Positioning time in range in diabetes management
Advani, A. (2020) · Diabetologia · doi:10.1007/s00125-019-05027-0 · Cited by 170
ISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Insulin delivery
Sherr, J. L., Schoelwer, M., Dos Santos, T. J., Reddy, L., Biester, T., Galderisi, A., van Dyk, J. C., Hilliard, M. E., Berget, C., & DiMeglio, L. A. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13421 · Cited by 152
Metadata
- Authors
- Petersson, J., Åkesson, K., Sundberg, F., & Särnblad, S.
- Venue
- Pediatric Diabetes
- Publisher
- Wiley
- Published
- 2019-01-31
- Volume
- 20
- Issue
- 3
- Pages
- 339-344
- ISSN
- 1399-543X (ISSN-L)
- 1399-5448
- OpenAlex
- W2909658141
- Cited by
- 74
- References
- 8
- FWCI
- 4.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Translating glycated hemoglobin A1c into time spent in glucose target range: A multicenter study. https://app.cochat.ai/papers/10.1111/pedi.12817
- The paper
- Petersson, J., Åkesson, K., Sundberg, F., & Särnblad, S. (2019). Translating glycated hemoglobin A1c into time spent in glucose target range: A multicenter study. Pediatric Diabetes. https://doi.org/10.1111/pedi.12817
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.