CoChat

Glycemic outcomes of children 2–6 years of age with type 1 diabetes during the pediatric MiniMed ™ 670G system trial

Open access
Forlenza, Gregory P., Ekhlaspour, Laya, DiMeglio, Linda A., Fox, Larry A., Rodriguez, Henry, Shulman, Dorothy I., Kaiserman, Kevin B., Liljenquist, David R., Shin, John, Lee, Scott W., Buckingham, Bruce A. · 2022 · Pediatric Diabetes
Cited by 67

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Highly variable insulin sensitivity, susceptibility to hypoglycemia and inability to effectively communicate hypoglycemic symptoms pose significant challenges for young children with type 1 diabetes (T1D). Herein, outcomes during clinical MiniMed™ 670G system use were evaluated in children aged 2-6 years with T1D. METHODS: Participants (N = 46, aged 4.6 ± 1.4 years) at seven investigational centers used the MiniMed™ 670G system in Manual Mode during a two-week run-in period followed by Auto Mode during a three-month study phase. Safety events, mean A1C, sensor glucose (SG), and percentage of time spent in (TIR, 70-180 mg/dl), below (TBR, <70 mg/dl) and above (TAR, >180 mg/dl) range were assessed for the run-in and study phase and compared using a paired t-test or Wilcoxon signed-rank test. RESULTS: From run-in to end of study (median 87.1% time in auto mode), mean A1C and SG changed from 8.0 ± 0.9% to 7.5 ± 0.6% (p < 0.001) and from 173 ± 24 to 161 ± 16 mg/dl (p < 0.001), respectively. Overall TIR increased from 55.7 ± 13.4% to 63.8 ± 9.4% (p < 0.001), while TBR and TAR decreased from 3.3 ± 2.5% to 3.2 ± 1.6% (p = 0.996) and 41.0 ± 14.7% to 33.0 ± 9.9% (p < 0.001), respectively. Overnight TBR remained unchanged and TAR was further improved 12:00 am-6:00 am. Throughout the study phase, there were no episodes of severe hypoglycemia or diabetic ketoacidosis (DKA) and no serious adverse device-related events. CONCLUSIONS: At-home MiniMed™ 670G Auto Mode use by young children safely improved glycemic outcomes compared to two-week open-loop Manual Mode use. The improvements are similar to those observed in older children, adolescents and adults with T1D using the same system for the same duration of time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/pedi.13312

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 67

Metadata

Authors
Forlenza, G. P., Ekhlaspour, L., DiMeglio, L. A., Fox, L. A., Rodriguez, H., Shulman, D. I., Kaiserman, K. B., Liljenquist, D. R., Shin, J., Lee, S. W., & Buckingham, B. A.
Venue
Pediatric Diabetes
Publisher
Wiley
Published
2022-01-31
Volume
23
Issue
3
Pages
324-329
ISSN
  • 1399-543X (ISSN-L)
  • 1399-5448
OpenAlex
W4206109217
Cited by
67
References
7
FWCI
9.03
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Glycemic outcomes of children 2–6 years of age with type 1 diabetes during the pediatric MiniMed ™ 670G system trial. https://app.cochat.ai/papers/10.1111/pedi.13312
The paper
Forlenza, G. P., Ekhlaspour, L., DiMeglio, L. A., Fox, L. A., Rodriguez, H., Shulman, D. I., Kaiserman, K. B., Liljenquist, D. R., Shin, J., Lee, S. W., & Buckingham, B. A. (2022). Glycemic outcomes of children 2–6 years of age with type 1 diabetes during the pediatric MiniMed ™ 670G system trial. Pediatric Diabetes. https://doi.org/10.1111/pedi.13312

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.