The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Restrictive blood transfusion practices are associated with improved patient outcomes
Abstract
Background: Blood transfusion has been cited as one of the five most overutilized therapeutic procedures in the U nited S tates. We assessed the impact of clinical decision support at computerized physician order entry and education on red blood cell (RBC) transfusions and clinical patient outcomes at our institution. Study Design and Methods: Clinical patient outcomes and RBC transfusions were assessed before and after implementation of a best practice alert triggered for transfusions when the hemoglobin level was higher than 7 g/dL for all inpatient discharges from J anuary 2008 through D ecember 2013. Retrospective clinical and laboratory data related to RBC transfusions were extracted: case‐mix complexity, patient discharges and selected surgical volumes, and patient outcomes (mortality, 30‐day readmissions, length of stay). Results: There was a significant improvement in RBC utilization as assessed by RBC units transfused per 100 patient‐days‐at‐risk. Concurrently, hospital‐wide clinical patient outcomes showed improvement (mortality, p = 0.034; length of stay, p = 0.003) or remained stable (30‐day readmission rates, p = 0.909). Outcome improvements were even more pronounced in patients who received blood transfusions, with decreased mortality rate (55.2 to 33.0, p < 0.001), length of stay (mean, 10.1 to 6.2 days, p < 0.001), and 30‐day readmission rate (136.9 to 85.0, p < 0.001). The mean number of units transfused per patient also declined (3.6 to 2.7, p < 0.001). Acquisition costs of RBC units per 1000 patient discharges decreased from $283,130 in 2009 to $205,050 in 2013 with total estimated savings of $6.4 million and likely far greater impact on total transfusion‐related costs. Conclusion: Improved blood utilization is associated with improved clinical patient outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Multicenter, Randomized, Controlled Clinical Trial of Transfusion Requirements in Critical Care
Hébert, P. C., Wells, G., Blajchman, M. A., Marshall, J., Martin, C., Pagliarello, G., Tweeddale, M., Schweitzer, I., & Yetisir, E. (1999) · New England Journal of Medicine · doi:10.1056/nejm199902113400601 · Cited by 5,187
Cited by
Patient Blood Management: Recommendations From the 2018 Frankfurt Consensus Conference
Mueller, M. M., Van Remoortel, H., Meybohm, P., Aranko, K., Aubron, C., Burger, R., Carson, J. L., Cichutek, K., De Buck, E., Devine, D., et al. (2019) · JAMA · doi:10.1001/jama.2019.0554 · Cited by 632
Interventions Aimed at Reducing Use of Low-Value Health Services: A Systematic Review
Colla, C. H., Mainor, A. J., Hargreaves, C., Sequist, T., & Morden, N. (2017) · Medical Care Research and Review · doi:10.1177/1077558716656970 · Cited by 357
Muñoz, M., Acheson, A. G., Bisbe, E., Butcher, A., Gómez‐Ramírez, S., Khalafallah, A. A., Kehlet, H., Kietaibl, S., Liumbruno, G. M., Meybohm, P., et al. (2018) · Anaesthesia · doi:10.1111/anae.14358 · Cited by 255
Matot, I., Nachmansson, N., Duev, O., Schulz, S., Schroeder‐Stein, K., Frede, S., & Abramovitch, R. (2017) · The FASEB Journal · doi:10.1096/fj.201700153r · Cited by 24
Metadata
- Authors
- Goodnough, L. T., Maggio, P., Hadhazy, E., Shieh, L., Hernandez‐Boussard, T., Khari, P., & Shah, N.
- Venue
- Transfusion
- Publisher
- Wiley
- Published
- 2014-07-04
- Volume
- 54
- Issue
- 10pt2
- Pages
- 2753-2759
- ISSN
- 0041-1132 (ISSN-L)
- 1537-2995
- OpenAlex
- W1838035547
- Cited by
- 192
- References
- 1
- FWCI
- 15.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.