CoChat

Vascular responsiveness measured by tissue oxygen saturation reperfusion slope is sensitive to different occlusion durations and training status

Open access
McLay, Kaitlin M., Gilbertson, James E., Pogliaghi, Silvia, Paterson, Donald H., Murias, Juan M. · 2016 · Experimental Physiology
Cited by 68

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

New Findings: What is the central question of this study? Is the near‐infrared spectroscopy‐derived measure of tissue oxygen saturation () reperfusion slope sensitive to a range of ischaemic conditions, and do differences exist between trained and untrained individuals? What is the main finding and its importance? The reperfusion rate is sensitive to different occlusion durations, and changes in the reperfusion slope in response to a variety of ischaemic challenges can be used to detect differences between two groups. These data indicate that near‐infrared spectroscopy‐derived measures of , specifically the reperfusion slope following a vascular occlusion, can be used as a sensitive measure of vascular responsiveness. The reperfusion rate of near‐infrared spectroscopy‐derived measures of tissue oxygen saturation () represents vascular responsiveness. This study examined whether the reperfusion slope of is sensitive to different ischaemic conditions (i.e. a dose–response relationship) and whether differences exist between two groups of different fitness levels. Nine healthy trained (T; age 25 ± 3 years; maximal oxygen uptake 63.4 ± 6.7 ml kg−1 min−1) and nine healthy untrained men (UT; age 21 ± 1 years; maximal oxygen uptake 46.6 ± 2.5 ml kg−1 min−1) performed a series of vascular occlusion tests of different durations (30 s, 1, 2, 3 and 5 min), each separated by 30 min. The was measured over the tibialis anterior using near‐infrared spectroscopy, with the reperfusion slope calculated as the upslope during 10 s following cuff release. The reperfusion slope was steeper in T compared with UT at all occlusion durations (P < 0.05). For the T group, the reperfusion slopes for 30 s and 1 min occlusions were less than for all longer durations (P < 0.05). The reperfusion slope following 2 min occlusion was similar to that for 3 min (P > 0.05), but both were less steep than for 5 min of occlusion. In UT, the reperfusion slope at 30 s was smaller than for all longer occlusion durations (P < 0.05), and 1 min occlusion resulted in a reperfusion slope that was less steep than following 2 and 3 min (P < 0.05), albeit not different from 5 min (P > 0.05). The present study demonstrated that the reperfusion rate of is sensitive to different occlusion durations, and that changes in the reperfusion rate in response to a variety of ischaemic challenges can be used to detect differences in vascular responsiveness between trained and untrained groups.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/ep085843

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 68

Metadata

Authors
McLay, K. M., Gilbertson, J. E., Pogliaghi, S., Paterson, D. H., & Murias, J. M.
Venue
Experimental Physiology
Publisher
Wiley
Published
2016-09-11
Volume
101
Issue
10
Pages
1309-1318
ISSN
  • 0958-0670 (ISSN-L)
  • 1469-445X
OpenAlex
W2496422676
Cited by
68
References
5
FWCI
10.09
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Vascular responsiveness measured by tissue oxygen saturation reperfusion slope is sensitive to different occlusion durations and training status. https://app.cochat.ai/papers/10.1113/ep085843
The paper
McLay, K. M., Gilbertson, J. E., Pogliaghi, S., Paterson, D. H., & Murias, J. M. (2016). Vascular responsiveness measured by tissue oxygen saturation reperfusion slope is sensitive to different occlusion durations and training status. Experimental Physiology. https://doi.org/10.1113/ep085843

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.