CoChat

Agreement between muscle saturation breakpoints and lactate thresholds: Muscles comparison and sex difference in world‐class Nordic skiers

Open access

The DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index; 27 of the 39 sources its claims cite were checked for support.

Abstract

Near‐infrared spectroscopy (NIRS) has emerged as a potential alternative method for determination of breakpoints equivalent to lactate thresholds. However, the optimal NIRS location remains unclear, particularly in Nordic skiing, which requires both upper‐ and lower‐limb contributions. This study aimed to evaluate the feasibility and accuracy of NIRS‐derived breakpoints determination (i.e., BP1 and BP2) compared to first (LT1) and second (LT2) lactate thresholds and to compare different muscle sites in male and female world‐class Nordic skiers. Fifty‐two world‐class Nordic skiers (29 males, 23 females) performed an incremental treadmill test on roller skis. NIRS sensors were located simultaneously on four muscles: vastus lateralis (VL), biceps femoris (BF), biceps brachii (BB), and triceps brachii (TB). Oxygen saturation () was collected and analysed to detect BP1 and BP2 vs. LT1 and LT2. First, BP1 was too often undetectable or inaccurately detected, suggesting an unsuitable practical use. Second, BP2 was detected in VL (88.5%), BF (96.2%) and BB (86.5%) but not in TB (24.1%). Third, there was a very good accuracy (i.e., bias [95% CI] in heart rate between BP2 and LT2 in VL (−0.6 bpm [−8.9, 7.8]), BF (+1.3 bpm [−2.8, 4.2]) and BB (+1.0 bpm [−7.5, 9.5]). Finally, no significant differences were found between male and female athletes. NIRS appears as an effective non‐invasive method for detecting breakpoint equivalent to LT2 in both male and female world‐class Nordic skiers, especially if positioned on both BB and BF.

Overview

CoChat Summary

TL;DR

In 52 world-class Nordic skiers, NIRS-derived BP1 was mostly undetectable or inaccurate, while BP2 was a reliable surrogate for LT2, especially at biceps femoris and biceps brachii. No significant sex differences were found in BP2 feasibility or accuracy.

Key findings

  • BP1 was often not usable: pooled detection was 69.2%, with high inter-individual variability in HR differences versus LT1 (e.g., VL −2.5 ± 6.4 bpm; BF +0.2 ± 5.2 bpm; BB −4.7 ± 7.9 bpm; TB −10.3 ± 9.0 bpm).
  • BP2 detection was high for VL (88.5%), BF (96.2%), and BB (86.5%), but low for TB (32.7%); detection reached 100% when at least one muscle was considered.
  • BP2 vs LT2 HR bias [95% CI] was very good: VL −0.6 bpm [−8.9, 7.8], BF +1.3 bpm [−2.8, 4.2], and BB +1.0 bpm [−7.5, 9.5]. Reliability was highest for BF (males ICC = 0.954, SEM = 0.58 bpm; females ICC = 0.904, SEM = 1.11 bpm).
  • No significant sex differences were found in BP determination feasibility or accuracy; BP accuracy was not correlated with body fat percentage (BP1 r = 0.08, P = 0.52; BP2 r = −0.05, P = 0.67).

Methods

  • Fifty-two world-class Nordic skiers (29 males, 23 females; 12 Tier 5, 40 Tier 4) performed an incremental treadmill roller-ski test using V2 technique, with 3-min work intervals and 15-s rests, 7% incline, starting at 9.0 km/h with 1 km/h increments.
  • NIRS sensors (Moxy Monitor) were placed simultaneously on the right vastus lateralis (VL), biceps femoris (BF), biceps brachii (BB), and triceps brachii (TB); SmO2, HR, capillary blood lactate, and skinfold thickness were measured.
  • BP1/BP2 were identified from SmO2 rate using segmented linear regression with visual inspection; LT1/LT2 were determined by the Dmax method. Agreement was assessed with Bland–Altman, ICC, and SEM, alongside repeated-measures ANOVA/Friedman tests, chi-square tests, and Pearson correlations.

Limitations

  • Stated: the Moxy monitor’s single-source continuous-wave technology has lower spatial resolution and appears less robust than multi-distance NIRS devices; findings are specific to world-class Nordic skiers/biathletes and may not transfer to other sports or lower-calibre athletes.
  • Stated: 3-min stages were used to accommodate elite participants, which may have altered BP detection precision compared with longer stages; no formal inter-rater reliability assessment was conducted, although curves were reviewed by two investigators with consensus.
  • Evident: the text reports 23 female athletes in the abstract and methods, but Table 1 lists female n = 22, an inconsistency in the reported sample.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1113/ep093311

Cites

62 of 62 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

FIGURE 1 Representative NIRS figures. (a) Example data set from an incremental step test. Black dots indicate the momentary muscle oxygen saturation (SmO2) values, red dots represent the last 2 min of each step, and black lines illustrate the slope regression analysis for each step. (b) The relationship between blood lactate (mmol L−1) and test steps, along with the SmO2 rate (in % s− 1) and steps. Breakpoints 1 and 2 are indicated by the dashed vertical lines.
FIGURE 1 Representative NIRS figures. (a) Example data set from an incremental step test. Black dots indicate the momentary muscle oxygen saturation (SmO2) values, red dots represent the last 2 min of each step, and black lines illustrate the slope regression analysis for each step. (b) The relationship between blood lactate (mmol L−1) and test steps, along with the SmO2 rate (in % s− 1) and steps. Breakpoints 1 and 2 are indicated by the dashed vertical lines.CC BY · PubMed Central
FIGURE 2 Box plot analysis showing mean differences (black squares) and 95% CI (thick darker horizontal lines) differences in HR at BP1 and LT1 (a) and BP2 and LT2 (b) for all athletes and for females and males. The vertical line inside the box indicates the median HR difference, representing the central value of the data. The lower and upper edges of the box represent the first quartile (Q1) (25th percentile) and the third quartile (Q3) (75th percentile) of the HR differences, respectively. The distance between Q1 and Q3 is the interquartile range (IQR). The lines extending from the box indicate the range of HR differences within 1.5× the IQR above Q3 and below Q1. They provide a sense of the spread of the central 50% of the data.
FIGURE 2 Box plot analysis showing mean differences (black squares) and 95% CI (thick darker horizontal lines) differences in HR at BP1 and LT1 (a) and BP2 and LT2 (b) for all athletes and for females and males. The vertical line inside the box indicates the median HR difference, representing the central value of the data. The lower and upper edges of the box represent the first quartile (Q1) (25th percentile) and the third quartile (Q3) (75th percentile) of the HR differences, respectively. The distance between Q1 and Q3 is the interquartile range (IQR). The lines extending from the box indicate the range of HR differences within 1.5× the IQR above Q3 and below Q1. They provide a sense of the spread of the central 50% of the data.CC BY · PubMed Central
FIGURE 3 Bland–Altman plots analysis. Each plot shows the differences in heart rate between the second breakpoint (BP2) and the second lactic threshold (LT2) for biceps femoris (BF) or biceps brachii (BB) in females (a, c) or males (b, d), respectively. The black squares represent the bias, and the thick darker horizontal lines indicate the limits of agreement (LOA).
FIGURE 3 Bland–Altman plots analysis. Each plot shows the differences in heart rate between the second breakpoint (BP2) and the second lactic threshold (LT2) for biceps femoris (BF) or biceps brachii (BB) in females (a, c) or males (b, d), respectively. The black squares represent the bias, and the thick darker horizontal lines indicate the limits of agreement (LOA).CC BY · PubMed Central

Verification

Claims the paper makes

15 Valid · 3 Not valid · 5 Not checked · 44 Own results and interpretations

21 more claims · 3 with their cited sources checked

Create a free account to see all 67 claims and to verify the 4 references still open.

See all claims — free account
  • It may state two separate claims as one. 24
  • Probably not a substantial claim. 19

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

5 of 8 · the rest aren’t loaded

3 more findings

Create a free account to see every finding of this check.

See all findings — free account

Citations

Cites

Show all 62 references

Research works printed but not linked: 1

  1. McCully, K. K., & Hamaoka, T. (2000). Near‐infrared spectroscopy: What can it tell us about oxygen saturation in skeletal muscle?. Exercise and Sport Sciences Reviews, 28(3), 123– 127. 10916704

Cited by

Metadata

Authors
Forot, J., Schorderet, F., Burdet, C., Brocherie, F., & Millet, G. P.
Affiliations
  • University of Lausanne (CH)
  • French Ski Federation Annecy France
  • Institut National du Sport, de l'Expertise et de la Performance (FR)
Corresponding author
Millet, Grégoire P.
Venue
Experimental Physiology
Publisher
Wiley
Published
2026-02-11
Volume
111
Issue
4
Pages
2002-2013
ISSN
  • 0958-0670 (ISSN-L)
  • 1469-445X
OpenAlex
W7128690272
Cited by
1
References
60
Citations by year
2026: 1
FWCI
3.05
Type
journal article
Language
en
Open access
Licence
Locations
  • Experimental Physiology (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • HAL (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • IRIS (submittedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
Keywords
lactate threshold, near-infrared spectroscopy, Nordic skiing, sex differences, muscle oxygen saturation, vastus lateralis, biceps femoris, biceps brachii, triceps brachii, heart rate, incremental treadmill test, roller skis, world-class athletes
MeSH terms
Adult, Exercise Test, Female, Humans, Male, Oxygen Consumption, Sex Characteristics, Sex Factors, Skiing, Anaerobic Threshold, Muscle, Skeletal, Spectroscopy, Near-Infrared, Lactic Acid, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-13, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-13 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.