CoChat

Cardiovascular and Respiratory Modulation of Tactile Afferents in the Human Finger Pad

Macefield, Vaughan G. · 2003 · Experimental Physiology
Cited by 36

The DOI matches its Crossref record.

Abstract

The human finger pad is highly vascularized so it might be expected that the on‐going cardiac pulsations in the vicinity of a cutaneous mechanoreceptor would be reflected in its spontaneous or evoked discharge. The purpose of this study was to examine the prevalence of this potential cardiac rhythmicity in a random sample of tactile afferents from the finger pad. Unitary recordings were made from 21 rapidly (‘fast’) adapting (18 FA I; 3 FA II) and 44 slowly adapting (17 SA I; 27 SA II) afferents via tungsten microelectrodes in the median nerve. Skin blood flow was measured over the pulp of a contralateral finger; ECG activity, blood pressure and respiration were also recorded. Cardiac modulation, present either as a simple pulse rhythm or as modulation of an on‐going discharge, was expressed by 44 % of the afferents. Only two out of 18 FA I units, and two out of three FA II units, exhibited cardiac rhythmicity, but their temporal coupling to the pulse was very tight. Modulation was more common for the slowly adapting afferents (57 %), and more prevalent among the SA II (65 %) than the SA I (47 %) classes. Nine spontaneously active SA II afferents exhibited respiratory rhythmicity, their background discharge falling during inspiration. It is concluded that cardiac modulation is common for both classes of slowly adapting tactile afferents (but less common for the rapidly adapting afferents), which may have implications for the sensory signalling of tactile information.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/eph8802548

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Macefield, V. G.
Venue
Experimental Physiology
Publisher
Wiley
Published
2003-09
Volume
88
Issue
5
Pages
617-625
ISSN
  • 0958-0670 (ISSN-L)
  • 1469-445X
OpenAlex
W2128328381
Cited by
36
References
0
FWCI
0.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.