Cardioventilatory Coupling in Resting Human Subjects
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In 48 conscious resting subjects we examined the temporal coupling of heart beat timing and the onset of inspiration (cardioventilatory coupling), and the relationship between coupling and spectral indices of autonomic function. Using the proportional Shannon entropy (SH α) of the RI‐1 interval (interval between inspiration and the preceding ECG R wave) as a measure of coupling we detected statistically significant coupling in 32 of the 48 subjects. This was confirmed by visual inspection of time series plots of RI intervals, in which coupling was evident as horizontal banding. Coupling resulted in a significant preference for whole number heart rate/respiratory frequency ratios. The strongest coupling was associated with low ventilatory frequency and high heart rate variability in the high (0.15‐0.40 Hz) and low (0.04‐0.15 Hz) frequency ranges, but was not related to blood pressure variability, or to a spectral measure of baroreflex sensitivity (α‐index, low frequency range). There was no difference in coupling strength between males and females. We have previously described cardioventilatory coupling in spontaneously breathing anaesthetised subjects. The current study extends those observations by demonstrating that the qualitative features of coupling seen during anaesthesia are also observed in the conscious state. We conclude that the role of coupling in normal physiological respiratory control needs to be more widely explored.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heartbeat synchronized with ventilation
Schäfer, C., Rosenblum, M. G., Kurths, J., & Abel, H.-H. (1998) · Nature · doi:10.1038/32567 · Cited by 731 · cited 2×
“The coupling process is distinct from the more widely known respiratory modulation of cardiovascular and autonomic efferent activity (Gilbey et al. 1984; Schafer et al. 1998).”
Background
Cited by
Jerath, R., Edry, J. W., Barnes, V. A., & Jerath, V. (2006) · Medical Hypotheses · doi:10.1016/j.mehy.2006.02.042 · Cited by 574
Considerations in the assessment of heart rate variability in biobehavioral research
Quintana, D. S., & Heathers, J. A. J. (2014) · Frontiers in Psychology · doi:10.3389/fpsyg.2014.00805 · Cited by 395
Nonlinear dynamics of cardiovascular ageing
Shiogai, Y., Stefanovska, A., & McClintock, P. V. E. (2010) · Physics Reports · doi:10.1016/j.physrep.2009.12.003 · Cited by 321
Cardiac and Respiratory Patterns Synchronize between Persons during Choir Singing
Müller, V., & Lindenberger, U. (2011) · PLoS ONE · doi:10.1371/journal.pone.0024893 · Cited by 256
“[11] found cardioventilatory coupling at both low (0.”
BackgroundRespiratory sinus arrhythmia in conscious humans during spontaneous respiration.
Larsen, P. D., Tzeng, Y. C., Sin, P. Y. W., & Galletly, D. C. (2010) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2010.04.021 · Cited by 161
Self-citation
Metadata
- Authors
- Tzeng, Y. C., Larsen, P. D., & Galletly, D. C.
- Venue
- Experimental Physiology
- Publisher
- Wiley
- Published
- 2003-11
- Volume
- 88
- Issue
- 6
- Pages
- 775-782
- ISSN
- 0958-0670 (ISSN-L)
- 1469-445X
- OpenAlex
- W2160996963
- Cited by
- 82
- References
- 1
- FWCI
- 1.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardioventilatory Coupling in Resting Human Subjects. https://app.cochat.ai/papers/10.1113/eph8802606
- The paper
- Tzeng, Y. C., Larsen, P. D., & Galletly, D. C. (2003). Cardioventilatory Coupling in Resting Human Subjects. Experimental Physiology. https://doi.org/10.1113/eph8802606
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.