A method for the determination in anæsthetized dogs of the right and left cardiac outputs has been described; it depends upon accurate and fast recording of the blood temperature changes which occur in the right ventricle and aorta when cold Ringer solution or blood is injected into the inferior vena cava. The curves defining the blood temperature changes are time‐concentration curves, from which the blood flow at the sites of the recording thermocouples can be estimated with an accuracy which is roughly the accuracy of the Fick method. Various errors to which the technique may be subject are considered; attempts have been made to compute their effects quantitatively. The method is here described as the “thermo‐dilution” method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/expphysiol.1954.sp001067

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 406

Metadata

Authors
Fegler, G.
Venue
Quarterly Journal of Experimental Physiology and Cognate Medical Sciences
Publisher
Wiley
Published
1954-08-16
Volume
39
Issue
3
Pages
153-164
ISSN
0033-5541 (ISSN-L)
OpenAlex
W2061263931
Cited by
406
References
0
FWCI
3.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MEASUREMENT OF CARDIAC OUTPUT IN ANÆSTHETIZED ANIMALS BY A THERMO‐DILUTION METHOD. https://app.cochat.ai/papers/10.1113/expphysiol.1954.sp001067
The paper
Fegler, G. (1954). MEASUREMENT OF CARDIAC OUTPUT IN ANÆSTHETIZED ANIMALS BY A THERMO‐DILUTION METHOD. Quarterly Journal of Experimental Physiology and Cognate Medical Sciences. https://doi.org/10.1113/expphysiol.1954.sp001067

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.