The DOI matches its Crossref record.
MEASUREMENT OF CARDIAC OUTPUT IN ANÆSTHETIZED ANIMALS BY A THERMO‐DILUTION METHOD
Abstract
A method for the determination in anæsthetized dogs of the right and left cardiac outputs has been described; it depends upon accurate and fast recording of the blood temperature changes which occur in the right ventricle and aorta when cold Ringer solution or blood is injected into the inferior vena cava. The curves defining the blood temperature changes are time‐concentration curves, from which the blood flow at the sites of the recording thermocouples can be estimated with an accuracy which is roughly the accuracy of the Fick method. Various errors to which the technique may be subject are considered; attempts have been made to compute their effects quantitatively. The method is here described as the “thermo‐dilution” method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A new technique for measurement of cardiac output by thermodilution in man
Ganz, W., Donoso, R., Marcus, H. S., Forrester, J. S., & Swan, H. J. C. (1971) · The American Journal of Cardiology · doi:10.1016/0002-9149(71)90436-x · Cited by 763
Measurement of blood flow by thermodilution
Ganz, W., & Swan, H. J. C. (1972) · The American Journal of Cardiology · doi:10.1016/0002-9149(72)90635-2 · Cited by 374
Errors in the measurement of cardiac output by thermodilution
Nishikawa, T., & Dohi, S. (1993) · Canadian Journal of Anaesthesia · doi:10.1007/bf03011312 · Cited by 302
Cardiac Output Monitoring Using Indicator-Dilution Techniques: Basics, Limits, and Perspectives
Reuter, D. A., Huang, C., Edrich, T., Shernan, S. K., & Eltzschig, H. K. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181cc885a · Cited by 284
Ganguli, M., Tobian, L., & Iwai, J. (1979) · Hypertension · doi:10.1161/01.hyp.1.1.3 · Cited by 90
Metadata
- Authors
- Fegler, G.
- Venue
- Quarterly Journal of Experimental Physiology and Cognate Medical Sciences
- Publisher
- Wiley
- Published
- 1954-08-16
- Volume
- 39
- Issue
- 3
- Pages
- 153-164
- ISSN
- 0033-5541 (ISSN-L)
- OpenAlex
- W2061263931
- Cited by
- 406
- References
- 0
- FWCI
- 3.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.