The DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Cardiac Output Monitoring Using Indicator-Dilution Techniques: Basics, Limits, and Perspectives
Abstract
The ability to monitor cardiac output is one of the important cornerstones of hemodynamic assessment for managing critically ill patients at increased risk for developing cardiac complications, and in particular in patients with preexisting cardiovascular comorbidities. For >30 years, single-bolus thermodilution measurement through a pulmonary artery catheter for assessment of cardiac output has been widely accepted as the "clinical standard" for advanced hemodynamic monitoring. In this article, we review this clinical standard, along with current alternatives also based on the indicator-dilution technique, such as the transcardiopulmonary thermodilution and lithium dilution techniques. In this review, not only the underlying technical principles and the unique features but also the limitations of each application of indicator dilution are outlined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
The Effectiveness of Right Heart Catheterization in the Initial Care of Critically III Patients
Connors, A. F. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540110043030 · Cited by 2,210
Catheterization of the Heart in Man with Use of a Flow-Directed Balloon-Tipped Catheter
Swan, H. J. C., Ganz, W., Forrester, J., Marcus, H., Diamond, G., & Chonette, D. (1970) · New England Journal of Medicine · doi:10.1056/nejm197008272830902 · Cited by 2,137
Sandham, J. D., Hull, R. D., Brant, R. F., Knox, L., Pineo, G. F., Doig, C. J., Laporta, D. P., Viner, S., Passerini, L., Devitt, H., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021108 · Cited by 1,529
Connors, A. F. (1996) · JAMA · doi:10.1001/jama.276.11.889 · Cited by 1,403
Critchley, L. A. H., & Critchley, J. A. J. H. (1999) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009982611386 · Cited by 1,325
Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution
Sakka, S. G., Rühl, C. C., Pfeiffer, U. J., Beale, R., McLuckie, A., Reinhart, K., & Meier-Hellmann, A. (2000) · Intensive Care Medicine · doi:10.1007/s001340050043 · Cited by 920
Scheer, B., Perel, A., & Pfeiffer, U. J. (2002) · Critical Care · doi:10.1186/cc1489 · Cited by 854
A new technique for measurement of cardiac output by thermodilution in man
Ganz, W., Donoso, R., Marcus, H. S., Forrester, J. S., & Swan, H. J. C. (1971) · The American Journal of Cardiology · doi:10.1016/0002-9149(71)90436-x · Cited by 763
Cited by
Critchley, L. A., Lee, A., & Ho, A. M.-H. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181f08a5b · Cited by 512
Cardiac output monitoring in paediatric cardiac surgery: A review
Woodman, H. M., Lee, C., Ahmed, A. N., Malik, B. A., Mellor, S., Brown, L. J., Gentle, L., & Harky, A. (2021) · Cardiology in the Young · doi:10.1017/s1047951120004680 · Cited by 7
Metadata
- Authors
- Reuter, D. A., Huang, C., Edrich, T., Shernan, S. K., & Eltzschig, H. K.
- Venue
- Anesthesia & Analgesia
- Published
- 2010-03
- Volume
- 110
- Issue
- 3
- Pages
- 799-811
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W1976595177
- Cited by
- 284
- References
- 71
- FWCI
- 20.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiac Output Monitoring Using Indicator-Dilution Techniques: Basics, Limits, and Perspectives. https://app.cochat.ai/papers/10.1213/ane.0b013e3181cc885a
- The paper
- Reuter, D. A., Huang, C., Edrich, T., Shernan, S. K., & Eltzschig, H. K. (2010). Cardiac Output Monitoring Using Indicator-Dilution Techniques: Basics, Limits, and Perspectives. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0b013e3181cc885a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.