The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Group III/IV muscle afferents limit the intramuscular metabolic perturbation during whole body exercise in humans
Open accessAbstract
Key points: The purpose of this study was to determine the role of group III/IV muscle afferents in limiting the endurance exercise‐induced metabolic perturbation assayed in muscle biopsy samples taken from locomotor muscle. Lumbar intrathecal fentanyl was used to attenuate the central projection of μ‐opioid receptor‐sensitive locomotor muscle afferents during a 5 km cycling time trial. The findings suggest that the central projection of group III/IV muscle afferent feedback constrains voluntary neural ‘drive’ to working locomotor muscle and limits the exercise‐induced intramuscular metabolic perturbation. Therefore, the CNS might regulate the degree of metabolic perturbation within locomotor muscle and thereby limit peripheral fatigue. It appears that the group III/IV muscle afferents are an important neural link in this regulatory mechanism, which probably serves to protect locomotor muscle from the potentially severe functional impairment as a consequence of severe intramuscular metabolic disturbance. To investigate the role of metabo‐ and mechanosensitive group III/IV muscle afferents in limiting the intramuscular metabolic perturbation during whole body endurance exercise, eight subjects performed 5 km cycling time trials under control conditions (CTRL) and with lumbar intrathecal fentanyl impairing lower limb muscle afferent feedback (FENT). Vastus lateralis muscle biopsies were obtained before and immediately after exercise. Motoneuronal output was estimated through vastus lateralis surface electromyography (EMG). Exercise‐induced changes in intramuscular metabolites were determined using liquid and gas chromatography‐mass spectrometry. Quadriceps fatigue was quantified by pre‐ to post‐exercise changes in potentiated quadriceps twitch torque (ΔQT single ) evoked by electrical femoral nerve stimulation. Although motoneuronal output was 21 ± 12% higher during FENT compared to CTRL ( P < 0.05), time to complete the time trial was similar (∼8.8 min). Compared to CTRL, power output during FENT was 10 ± 4% higher in the first half of the time trial, but 11 ± 5% lower in the second half (both P < 0.01). The exercise‐induced increase in intramuscular inorganic phosphate, H + , adenosine diphosphate, lactate and phosphocreatine depletion was 55 ± 30, 62 ± 18, 129 ± 63, 47 ± 14 ( P < 0.001) and 27 ± 14% ( P < 0.01) greater in FENT than CTRL. ΔQT single was greater following FENT than CTRL (−52 ± 2 vs −31 ± 1%, P < 0.001) and this difference was positively correlated with the difference in inorganic phosphate ( r 2 = 0.79; P < 0.01) and H + ( r 2 = 0.92; P < 0.01). In conclusion, during whole body exercise, group III/IV muscle afferents provide feedback to the CNS which, in turn, constrains motoneuronal output to the active skeletal muscle. This regulatory mechanism limits the exercise‐induced intramuscular metabolic perturbation, preventing an abnormal homeostatic challenge and excessive peripheral fatigue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Decoding the neural drive to muscles from the surface electromyogram
Farina, D., Holobar, A., Merletti, R., & Enoka, R. M. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.10.040 · Cited by 383
An evaluation of the predictive validity and reliability of ventilatory threshold
AMANN, M., SUBUDHI, A. W., WALKER, J., EISENMAN, P., SHULTZ, B., & FOSTER, C. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000142305.18543.34 · Cited by 90
Self-citation
Cited by
Périard, J. D., Eijsvogels, T. M. H., & Daanen, H. A. M. (2021) · Physiological Reviews · doi:10.1152/physrev.00038.2020 · Cited by 647
Effects of surgical and FFP2/N95 face masks on cardiopulmonary exercise capacity
Fikenzer, S., Uhe, T., Lavall, D., Rudolph, U., Falz, R., Busse, M., Hepp, P., & Laufs, U. (2020) · Clinical Research in Cardiology · doi:10.1007/s00392-020-01704-y · Cited by 370
Fatigue and Human Performance: An Updated Framework
Behrens, M., Gube, M., Chaabene, H., Prieske, O., Zenon, A., Broscheid, K.-C., Schega, L., Husmann, F., & Weippert, M. (2023) · Sports Medicine · doi:10.1007/s40279-022-01748-2 · Cited by 324
Recovery of central and peripheral neuromuscular fatigue after exercise
Carroll, T. J., Taylor, J. L., & Gandevia, S. C. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00775.2016 · Cited by 307
Hureau, T. J., Broxterman, R. M., Weavil, J. C., Lewis, M. T., Layec, G., & Amann, M. (2022) · The Journal of Physiology · doi:10.1113/jp283036 · Cited by 100
Self-citation
Metadata
- Authors
- Blain, G. M., Mangum, T. S., Sidhu, S. K., Weavil, J. C., Hureau, T. J., Jessop, J. E., Bledsoe, A. D., Richardson, R. S., & Amann, M.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 2016-07-08
- Volume
- 594
- Issue
- 18
- Pages
- 5303-5315
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2418253088
- Cited by
- 183
- References
- 2
- FWCI
- 36.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.