Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is known
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The relation of pulsatile pressure to flow in arteries
McDonald, D. A. (1955) · The Journal of Physiology · doi:10.1113/jphysiol.1955.sp005275 · Cited by 220
Lambossy, P. (1952) · Helvetica Physica Acta (Switzerland) · Cited by 66
The velocity of blood flow in the rabbit aorta studied with high‐speed cinematography
McDonald, D. A. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004797 · Cited by 48
Cited by
Items 101–200 of 1,001
Womersley, J. R. (1958) · Physics in Medicine and Biology · doi:10.1088/0031-9155/2/4/301 · Cited by 131
Self-citationEarly turbulence and pulsatile flows enhance diodicity of Tesla’s macrofluidic valve
Nguyen, Q. M., Abouezzi, J., & Ristroph, L. (2021) · Nature Communications · doi:10.1038/s41467-021-23009-y · Cited by 130
Cheng, C. P., Parker, D., & Taylor, C. A. (2002) · Annals of Biomedical Engineering · doi:10.1114/1.1511239 · Cited by 130
Takizawa, K., Christopher, J., Tezduyar, T. E., & Sathe, S. (2009) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.1241 · Cited by 129
The Hydrodynamics of the Arterial Circulation
McDonald, D. A., & Taylor, M. G. (1959) · Progress in Biophysics and Biophysical Chemistry · doi:10.1016/s0096-4174(18)30167-7 · Cited by 129
Baharoglu, M. I., Lauric, A., Gao, B., & Malek, A. M. (2012) · Journal of neurosurgery · doi:10.3171/2011.11.jns11311 · Cited by 128
Buchanan, J. R., Kleinstreuer, C., Hyun, S., & Truskey, G. A. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00088-5 · Cited by 128
Flow behaviour of blood cells and rigid spheres in an annular vortex
Karino, T., & Goldsmith, H. L. (1977) · Philosophical transactions of the Royal Society of London. Series B, Biological sciences · doi:10.1098/rstb.1977.0095 · Cited by 126
Campbell, I. C., Ries, J., Dhawan, S. S., Quyyumi, A. A., Taylor, W. R., & Oshinski, J. N. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4006681 · Cited by 125
Physiologic blood flow is turbulent
Saqr, K. M., Tupin, S., Rashad, S., Endo, T., Niizuma, K., Tominaga, T., & Ohta, M. (2020) · Scientific Reports · doi:10.1038/s41598-020-72309-8 · Cited by 123
Goldwyn, R. M., & Watt, T. B. (1967) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1967.4502455 · Cited by 123
Remuzzi, A., & Ene‐Iordache, B. (2013) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.03450413 · Cited by 122
Weston, M. W., Rhee, K., & Tarbell, J. M. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00028-3 · Cited by 121
Shemer, L., Wygnanski, I. J., & Kit, E. (1985) · Journal of Fluid Mechanics · doi:10.1017/s0022112085001276 · Cited by 121
Hermez, L. A., Spence, C. J. T., Payton, M. J., Nouraei, S. A. R., Patel, A., & Barnes, T. (2019) · Anaesthesia · doi:10.1111/anae.14541 · Cited by 120
Three-dimensional computational prediction of cerebrospinal fluid flow in the human brain
Sweetman, B., Xenos, M. A., Verbick, L. Z., & Linninger, A. A. (2011) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2010.12.001 · Cited by 120
Assessment of flow instabilities in the healthy aorta using flow‐sensitive MRI
Stalder, A. F., Frydrychowicz, A. P., Russe, M. F., Korvink, J. G., Hennig, J., Li, K., & Markl, M. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22512 · Cited by 119
Pulsatile Flow in Microfluidic Systems
Dincau, B. M., Dressaire, E., & Sauret, A. (2019) · Small · doi:10.1002/smll.201904032 · Cited by 118
Geoghegan, P. H., Buchmann, N., Spence, C. J. T., Moore, S., & Jermy, M. (2012) · Experiments in Fluids · doi:10.1007/s00348-011-1258-0 · Cited by 118
Groenendijk, B. C. W., Van der Heiden, K., Hierck, B. P., & Poelmann, R. E. (2007) · Physiology · doi:10.1152/physiol.00023.2007 · Cited by 105
Calamante, F., Yim, P. J., & Cebral, J. R. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00090-9 · Cited by 117
Feeding behaviour of tsetse flies infected with salivarian trypanosomes
Jenni, L., Molyneux, D. H., Livesey, J. L., & Galun, R. (1980) · Nature · doi:10.1038/283383a0 · Cited by 117
Tan, F. P. P., Soloperto, G., Bashford, S., Wood, N. B., Thom, S., Hughes, A. D., & Xu, X. Y. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2978992 · Cited by 114
Salman, H. E., Ramazanlı, B., Yavuz, M. M., & Yalcin, H. C. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00111 · Cited by 113
Cheng, C. P., Herfkens, R. J., & Taylor, C. A. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00641.2002 · Cited by 113
The flow of suspensions through tubes
Takano, M., Goldsmith, H. L., & Mason, S. G. (1968) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(68)90034-9 · Cited by 112
A pulse wave propagation model to support decision-making in vascular access planning in the clinic
Huberts, W., Bode, A. S., Kroon, W., Planken, R. N., Tordoir, J. H. M., van de Vosse, F. N., & Bosboom, E. M. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.07.015 · Cited by 111
Physiological fluid dynamics: a survey?
Lighthill, M. J. (1972) · Journal of Fluid Mechanics · doi:10.1017/s0022112072001557 · Cited by 111
Flow and pressure drop fluctuations in a vertical tube subject to low frequency oscillations
Pendyala, R., Jayanti, S., & Balakrishnan, A. R. (2007) · Nuclear Engineering and Design · doi:10.1016/j.nucengdes.2007.06.010 · Cited by 110
Space–time fluid–structure interaction modeling of patient‐specific cerebral aneurysms
Tezduyar, T. E., Takizawa, K., Brummer, T., & Chen, P. R. (2011) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.1433 · Cited by 108
A lattice Boltzmann model for Jeffreys viscoelastic fluid
Giraud, L., d’Humières, D., & Lallemand, P. (1998) · Europhysics Letters (EPL) · doi:10.1209/epl/i1998-00296-0 · Cited by 108
Present State of Art on Pulsatile Flow Theory. Part 1. Laminar and Transitional Flow Regimes.
Gündoğdu, M. Y., & Çarpınlıoğlu, M. Ö. (1999) · JSME International Journal Series B · doi:10.1299/jsmeb.42.384 · Cited by 107
Laminar-Turbulent Transition Process in Pulsatile Flow
Yellin, E. L. (1966) · Circulation Research · doi:10.1161/01.res.19.4.791 · Cited by 106
Particle deposition in the human tracheobronchial airways due to transient inspiratory flow patterns
Li, Z., Kleinstreuer, C., & Zhang, Z. (2007) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2007.03.010 · Cited by 105
Ottesen, J. T. (2003) · Journal of Mathematical Biology · doi:10.1007/s00285-002-0179-1 · Cited by 105
Wave intensity analysis and the development of the reservoir–wave approach
Tyberg, J. V., Davies, J. E., Wang, Z., Whitelaw, W. A., Flewitt, J. A., Shrive, N. G., Francis, D. P., Hughes, A. D., Parker, K. H., & Wang, J.-J. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0430-z · Cited by 104
“This analysis combines aspects of the Windkessel theory proposed by Frank [8] with the wave theories proposed by Womersley [28] and McDonald [11].”
BackgroundMethodElastography imaging: the 30 year perspective
Ormachea, J., & Parker, K. J. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abca00 · Cited by 104
“A later landmark development in theoretical treatments was Womersley’s solution for pulsatile flow in which a stiff arterial wall is assumed along with a periodic frequency of the heartbeat (Womersley 1955), and this was extended to the case of elastic vessel walls (Barnard et al 1966).”
BackgroundChattopadhyay, H., Durst, F., & Ray, S. (2006) · International Communications in Heat and Mass Transfer · doi:10.1016/j.icheatmasstransfer.2005.12.008 · Cited by 104
The onset of turbulence in physiological pulsatile flow in a straight tube
Peacock, J., Jones, T., Tock, C., & Lutz, R. (1998) · Experiments in Fluids · doi:10.1007/s003480050144 · Cited by 104
Allometric scaling laws of metabolism
da Silva, J. K. L., Garcia, G. J. M., & Barbosa, L. A. (2006) · Physics of Life Reviews · doi:10.1016/j.plrev.2006.08.001 · Cited by 104
Influence of wall thickness on fluid–structure interaction computations of cerebral aneurysms
Torii, R., Oshima, M., Kobayashi, T., Takagi, K., & Tezduyar, T. E. (2009) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.1289 · Cited by 103
Cheng, C. P., Herfkens, R. J., & Taylor, C. A. (2003) · Atherosclerosis · doi:10.1016/s0021-9150(03)00099-6 · Cited by 103
Chandra, S., Raut, S. S., Jana, A., Biederman, R. W., Doyle, M., Muluk, S. C., & Finol, E. A. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4024275 · Cited by 100
Endothelialization and Flow Conditioning of Fibrin-Based Media-Equivalents
Isenberg, B. C., Williams, C., & Tranquillo, R. T. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9101-0 · Cited by 101
A Review of Arterial Phantom Fabrication Methods for Flow Measurement Using PIV Techniques
Yazdi, S. G., Geoghegan, P. H., Docherty, P. D., Jermy, M., & Khanafer, A. (2018) · Annals of Biomedical Engineering · doi:10.1007/s10439-018-2085-8 · Cited by 99
Torii, R., Oshima, M., Kobayashi, T., Takagi, K., & Tezduyar, T. E. (2007) · International Journal for Numerical Methods in Fluids · doi:10.1002/fld.1497 · Cited by 99
Sequentially-Coupled Arterial Fluid–Structure Interaction (SCAFSI) technique
Tezduyar, T. E., Schwaab, M., & Sathe, S. (2008) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2008.05.024 · Cited by 99
Modeling and experimental validation of a piezoelectric micropump with novel no-moving-part valves
Izzo, I., Accoto, D., Menciassi, A., Schmitt, L., & Dario, P. (2006) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2006.01.049 · Cited by 99
Hsiai, T. K., Cho, S. K., Honda, H. M., Hama, S. Y., Navab, M., Demer, L. L., & Ho, C. (2002) · Annals of Biomedical Engineering · doi:10.1114/1.1484222 · Cited by 99
Suh, G.-Y. K., Les, A. S., Tenforde, A. S., Shadden, S. C., Spilker, R. L., Yeung, J. J., Cheng, C. P., Herfkens, R. J., Dalman, R. L., & Taylor, C. A. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0313-6 · Cited by 99
Tavelli, M., & Dumbser, M. (2016) · Journal of Computational Physics · doi:10.1016/j.jcp.2016.05.009 · Cited by 97
A numerical solution of laminar forced convection in a heated pipe subjected to a reciprocating flow
Zhao, T. S., & Cheng, P. (1995) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(95)00017-4 · Cited by 96
The role of the Womersley number in pulsatile blood flow
Rohlf, K., & Tenti, G. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00103-2 · Cited by 95
Ocular blood flow as a clinical observation: Value, limitations and data analysis
Harris, A., Guidoboni, G., Siesky, B. A., Mathew, S., Vercellin, A. C. V., Rowe, L. W., & Arciero, J. C. (2020) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100841 · Cited by 95
Adaptive boundary layer meshing for viscous flow simulations
Sahni, O., Jansen, K. E., Shephard, M. S., Taylor, C. A., & Beall, M. W. (2008) · Engineering With Computers · doi:10.1007/s00366-008-0095-0 · Cited by 95
Effect of the laryngeal jet on particle deposition in the human trachea and upper bronchial airways
Chan, T. L., Schreck, R. M., & Lippmann, M. (1980) · Journal of Aerosol Science · doi:10.1016/0021-8502(80)90117-2 · Cited by 95
Gas and aerosol mixing in the acinus
Tsuda, A., Henry, F. S., & Butler, J. P. (2008) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2008.02.010 · Cited by 94
An experimental study of transitional pulsatile pipe flow
Trip, R., Kuik, D. J., Westerweel, J., & Poelma, C. (2012) · Physics of Fluids · doi:10.1063/1.3673611 · Cited by 94
Kabinejadian, F., & Ghista, D. N. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.10.001 · Cited by 94
Bourke, J. M., Porter, W. R., Ridgely, R. C., Lyson, T. R., Schachner, E. R., Bell, P. R., & Witmer, L. M. (2014) · The Anatomical Record · doi:10.1002/ar.23046 · Cited by 93
Zhang, X., Feng, M., & Ge, W. (2008) · Journal of Mathematical Analysis and Applications · doi:10.1016/j.jmaa.2008.11.082 · Cited by 93
Glor, F., Long, Q., Hughes, A. D., Augst, A. D., Ariff, B., Thom, S., Verdonck, P., & Xu, X. Y. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1537694 · Cited by 92
Vascular Stiffening in Pulmonary Hypertension: Cause or Consequence? (2013 Grover Conference Series)
Tan, W., Madhavan, K. P. C., Hunter, K. S., Park, D., & Stenmark, K. R. (2014) · Pulmonary Circulation · doi:10.1086/677370 · Cited by 92
Numerical and experimental models of post-operative realistic flows in stenosed coronary bypasses
Bertolotti, C., Deplano, V., Fuseri, J., & Dupouy, P. J. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00027-6 · Cited by 92
Ene‐Iordache, B., Mosconi, L., Antiga, L., Bruno, S., Anghileri, A., Remuzzi, G., & Remuzzi, A. (2003) · Endothelium · doi:10.1080/10623320303365 · Cited by 91
Suh, G.-Y. K., Les, A. S., Tenforde, A. S., Shadden, S. C., Spilker, R. L., Yeung, J. J., Cheng, C. P., Herfkens, R. J., Dalman, R. L., & Taylor, C. A. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0202-4 · Cited by 91
Data-driven cardiovascular flow modelling: examples and opportunities
Arzani, A., & Dawson, S. T. M. (2021) · Journal of The Royal Society Interface · doi:10.1098/rsif.2020.0802 · Cited by 90
Permeate flux enhancement by pressure and flow pulsations in microfiltration with mineral membranes
Gupta, B. B., Blanpain-Avet, P., & Jaffrin, M. Y. (1992) · Journal of Membrane Science · doi:10.1016/0376-7388(92)80111-v · Cited by 90
Mathematical modelling of arterial fluid dynamics
Pedley, T. J. (2003) · Journal of Engineering Mathematics · doi:10.1023/b:engi.0000007978.33352.59 · Cited by 89
Toward Noninvasive Blood Pressure Assessment in Arteries by Using Ultrasound
Beulen, B. W. A. M. M., Bijnens, N., Koutsouridis, G. G., Brands, P. J., Rutten, M. C. M., & van de Vosse, F. N. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2011.01.020 · Cited by 88
Castro, M. A., Putman, C. M., & Cebral, J. R. (2006) · Academic Radiology · doi:10.1016/j.acra.2006.03.011 · Cited by 88
Li, P., Shen, T. T., Johnstone, M., & Wang, R. K. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.002051 · Cited by 87
Tuning Multidomain Hemodynamic Simulations to Match Physiological Measurements
Spilker, R. L., & Taylor, C. A. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0011-9 · Cited by 86
Davies, J. E., Hadjiloizou, N., Leibovich, D., Malaweera, A. S. N., Alastruey, J., Whinnett, Z. I., Manisty, C., Francis, D. P., Aguado‐Sierra, J., Foale, R. A., et al. (2007) · Artery Research · doi:10.1016/j.artres.2007.08.001 · Cited by 86
Three-Dimensional Hemodynamics in the Human Pulmonary Arteries Under Resting and Exercise Conditions
Tang, B. T., Fonte, T. A., Chan, F. P., Tsao, P. S., Feinstein, J. A., & Taylor, C. A. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0124-1 · Cited by 86
Choi, J., Xia, G., Tawhai, M. H., Hoffman, E. A., & Lin, C. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0110-7 · Cited by 85
Fluid Dynamics of Heart Development
Santhanakrishnan, A., & Miller, L. A. (2011) · Cell Biochemistry and Biophysics · doi:10.1007/s12013-011-9158-8 · Cited by 85
Mesoscopic simulations of systolic flow in the human abdominal aorta
Artoli, A. M., Hoekstra, A. G., & Sloot, P. M. A. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.01.033 · Cited by 85
Viscoelastic properties of blood and blood analogs
Thurston, G. B. (1996) · Advances in hemodynamics and hemorheology · doi:10.1016/s1873-9784(96)80003-9 · Cited by 84
Yu, S. C. M. (2000) · International Journal of Heat and Fluid Flow · doi:10.1016/s0142-727x(99)00058-2 · Cited by 83
Partitioned block-Gauss–Seidel coupling for dynamic fluid–structure interaction
Wood, C., Gil, A. J., Hassan, O., & Bonet, J. (2008) · Computers & Structures · doi:10.1016/j.compstruc.2008.08.005 · Cited by 83
Hemodynamics of Flow Diverters
Dholakia, R., Sadasivan, C., Fiorella, D. J., Woo, H. H., & Lieber, B. B. (2016) · Journal of Biomechanical Engineering · doi:10.1115/1.4034932 · Cited by 83
Do Plaques Grow Upstream or Downstream? An Angiographic Study in the Femoral Artery
Smedby, Ö. (1997) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.17.5.912 · Cited by 83
High resolution turbulence modelling of airflow in an idealised human extra-thoracic airway
Ball, C. G., Uddin, M., & Pollard, A. (2007) · Computers & Fluids · doi:10.1016/j.compfluid.2007.07.021 · Cited by 82
Lipovsky, B. P., & Dunham, E. M. (2015) · Journal of Geophysical Research Solid Earth · doi:10.1002/2014jb011286 · Cited by 82
The effect of wall mechanical properties on patency of arterial grafts.
Kidson, I. G. (1983) · PubMed · Cited by 82
Mathematical Problems in Classical and Non-Newtonian Fluid Mechanics
Galdi, G. P. (2008) · Birkhäuser Basel eBooks · doi:10.1007/978-3-7643-7806-6_3 · Cited by 79
Watanabe, S., Tero, A., Takamatsu, A., & Nakagaki, T. (2011) · Biosystems · doi:10.1016/j.biosystems.2011.05.001 · Cited by 78
Hofemeier, P., & Sznitman, J. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01117.2014 · Cited by 78
Oscillatory flow in microchannels
Morris, C. J., & Forster, F. K. (2004) · Experiments in Fluids · doi:10.1007/s00348-003-0776-9 · Cited by 78
A method for dynamic system characterization using hydraulic series resistance
Kim, D., Chesler, N. C., & Beebe, D. J. (2006) · Lab on a Chip · doi:10.1039/b517054k · Cited by 78
Effects of Mechanical Stress on Endothelial Cells In Situ and In Vitro
Katoh, K. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms242216518 · Cited by 78
Computational Fluid Dynamics Modeling of Intracranial Aneurysms:
Cebral, J. R., Pergolizzi, R. S., & Putman, C. M. (2007) · Academic Radiology · doi:10.1016/j.acra.2007.03.008 · Cited by 77
Rabbitt, R. D., Boyle, R., & Highstein, S. M. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.82.2.1033 · Cited by 77
MHD pulsatile flow of engine oil based carbon nanotubes between two concentric cylinders
Haq, R. U., Shahzad, F., & Al‐Mdallal, Q. M. (2016) · Results in Physics · doi:10.1016/j.rinp.2016.11.057 · Cited by 75
de Loubens, C., Lentle, R. G., Love, R. J., Hulls, C., & Janssen, P. W. M. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2013.0027 · Cited by 75
An experimental investigation of flow in an oscillating pipe
Clamen, M., & Minton, P. (1977) · Journal of Fluid Mechanics · doi:10.1017/s0022112077002146 · Cited by 75
Effects of wall distensibility in hemodynamic simulations of an arteriovenous fistula
McGah, P. M., Leotta, D. F., Beach, K. W., & Aliseda, A. (2013) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-013-0527-7 · Cited by 74
Effects of pulsatile blood flow in large vessels on thermal dose distribution during thermal therapy
Horng, T., Lin, W.-L., Liauh, C., & Shih, T. (2007) · Medical Physics · doi:10.1118/1.2712415 · Cited by 74
Pinho, N., Castro, C. F., António, C. A. C., Bettencourt, N., Sousa, L. C., & Pinto, S. I. S. (2018) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-018-1904-2 · Cited by 74
Metadata
- Authors
- Womersley, J. R.
- Corresponding author
- Womersley, J. R.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1955-03-28
- Volume
- 127
- Issue
- 3
- Pages
- 553-563
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- PMC
- PMC1365740
- OpenAlex
- W2067298651
- Cited by
- 1,835
- References
- 3
- Citations by year
- 2026: 59 · 2025: 77 · 2024: 61 · 2023: 88 · 2022: 82 · 2021: 85 · 2020: 68 · 2019: 85 · 2018: 63 · 2017: 62 · 2016: 65 · 2015: 53 · 2014: 100 · 2013: 63 · 2012: 57
- FWCI
- 6.91
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- The Journal of Physiology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Hematology › Blood properties and coagulation
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- arterial blood flow, velocity calculation, flow rate, viscous drag, pressure gradient, hemodynamics, blood viscosity
- MeSH terms
- Arteries, Blood Circulation, Cardiovascular System, Humans, Pressure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.