Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is known
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The relation of pulsatile pressure to flow in arteries
McDonald, D. A. (1955) · The Journal of Physiology · doi:10.1113/jphysiol.1955.sp005275 · Cited by 220
Lambossy, P. (1952) · Helvetica Physica Acta (Switzerland) · Cited by 66
The velocity of blood flow in the rabbit aorta studied with high‐speed cinematography
McDonald, D. A. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004797 · Cited by 48
Cited by
Items 701–800 of 1,001
A numerical study of an unsteady laminar flow in a doubly constricted 3D vessel
Kumar, B., Yamaguchi, T., Liu, H., & Himeno, R. (2002) · International Journal for Numerical Methods in Fluids · doi:10.1002/fld.191 · Cited by 18
Linearity and frequency response of fleisch type pneumotachometers
Zock, J. P. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00581522 · Cited by 18
Isabey, D. (1982) · Journal of Biomechanics · doi:10.1016/0021-9290(82)90061-6 · Cited by 18
The relationship of pressure gradient to blood velocity based on a continuum theory of blood
Kline, K. A., & Allen, S. J. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90087-6 · Cited by 18
Multiscale numerical analysis of airflow in CT-based subject specific breathing human lungs
Choi, J. (2011) · doi:10.17077/etd.n7qno7h9 · Cited by 18
Stanley, N., Ciero, A., Timms, W., & Hewlin, R. L. (2023) · ASME Open Journal of Engineering · doi:10.1115/1.4056639 · Cited by 17
Ramazanlı, B., Yagmur, O., Sarioglu, E. C., & Salman, H. E. (2025) · Bioengineering · doi:10.3390/bioengineering12050437 · Cited by 17
On the boundary conditions of cerebral aneurysm simulations
Ugron, Á., & Paál, G. (2014) · Periodica Polytechnica Mechanical Engineering · doi:10.3311/ppme.7392 · Cited by 17
The life and times of Donald A. McDonald
Nichols, W. W., & O’Rourke, M. F. (2007) · Artery Research · doi:10.1016/j.artres.2007.08.002 · Cited by 17
Aramburu, J., Antón, R., Bernal, N., Rivas, A., Ramos, J. C., Sangro, B., & Bilbao, J. I. (2015) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411915578549 · Cited by 17
Sisini, F., Toro, E. F., Gambaccini, M., & Zamboni, P. (2015) · Behavioural Neurology · doi:10.1155/2015/170756 · Cited by 17
Classification of tracheal stenosis in children based on computational aerodynamics
Poynot, W. J., Gonthier, K. A., Dunham, M. E., & Crosby, T. W. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2020.109752 · Cited by 17
Melito, G. M., Müller, T. S., Badeli, V., Ellermann, K., Brenn, G., & Reinbacher‐Köstinger, A. (2021) · Reliability Engineering & System Safety · doi:10.1016/j.ress.2021.107663 · Cited by 17
Volumetric lattice Boltzmann method for wall stresses of image-based pulsatile flows
Zhang, X., Gomez-Paz, J., Chen, X., McDonough, J. M., Islam, M. M., Andreopoulos, Y., Zhu, L., & Yu, H. W. (2022) · Scientific Reports · doi:10.1038/s41598-022-05269-w · Cited by 17
Bozuyuk, U., Ozturk, H., & Sitti, M. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202300099 · Cited by 17
Fahim, M., Sajid, M., & Ali, N. (2024) · Numerical Heat Transfer Part A Applications · doi:10.1080/10407782.2024.2326961 · Cited by 17
The role of respiratory flow asynchrony on convective mixing in the pulmonary acinus
Hofemeier, P., Fishler, R., & Sznitman, J. (2014) · Fluid Dynamics Research · doi:10.1088/0169-5983/46/4/041407 · Cited by 17
Theory of isobaric pressure exchanger for desalination
Mei, C. C., Liu, Y.-H., & Law, A. W. (2012) · Desalination and Water Treatment · doi:10.5004/dwt.2012.2962 · Cited by 17
Qi, P., Li, X., Li, X., Qiao, S., Tan, S., & Chen, Y. (2019) · Annals of Nuclear Energy · doi:10.1016/j.anucene.2019.03.027 · Cited by 17
Multiple-time-scaling lattice Boltzmann method for the convection diffusion equation
Li, L. (2019) · Physical review. E · doi:10.1103/physreve.99.063301 · Cited by 17
Backflow stabilization by deconvolution-based large eddy simulation modeling
Xu, H., Baroli, D., Massimo, F. D., Quaini, A., & Veneziani, A. (2019) · Journal of Computational Physics · doi:10.1016/j.jcp.2019.109103 · Cited by 17
A Survey of Quantitative Descriptors of Arterial Flows
Gallo, D., Isu, G., Massai, D., Pennella, F., Deriu, M. A., Ponzini, R., Bignardi, C., Audenino, A. L., Rizzo, G., & Morbiducci, U. (2013) · Lecture notes in computational vision and biomechanics · doi:10.1007/978-94-007-7769-9_1 · Cited by 17
Blood Flow and Fluid-Structure Interactions in the Human Aorta During Traumatic Rupture Conditions
Lee, S.-H., & Kent, R. W. (2007) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2007-22-0010 · Cited by 17
Dynamics of hydrocephalus: a physical approach
Bouzerar, R., Tekaya, I., Bouzerar, R., & Balédent, O. (2011) · Journal of Biological Physics · doi:10.1007/s10867-011-9239-3 · Cited by 17
Wall shear stress variations in a 90-degree bifurcation in 3D pulsating flows
Evegren, P., Fuchs, L. J., & Revstedt, J. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.11.008 · Cited by 17
Computational Modelling of Blood Flow Development and Its Characteristics in Magnetic Environment
Shit, G. C. (2013) · Modelling and Simulation in Engineering · doi:10.1155/2013/758748 · Cited by 17
An in vitro study on the effect of branch points on the stability of coronary artery flow
Peacock, J., Jones, T., Tock, C., & Lutz, R. (1997) · Medical Engineering & Physics · doi:10.1016/s1350-4533(96)00046-x · Cited by 17
Hemodynamics and wall shear rate in the abdominal aorta of dogs. Effects of vasoactive agents.
White, K. C., Kavanaugh, J. F., Wang, D. M., & Tarbell, J. M. (1994) · Circulation Research · doi:10.1161/01.res.75.4.637 · Cited by 17
Blood flow subject to a single cycle of body acceleration
Sud, V. K., & Sekhon, G. S. (1984) · Bulletin of Mathematical Biology · doi:10.1007/bf02462080 · Cited by 17
Pilot clinical study of aneurysm rupture using image-based computational fluid dynamics models
Cebral, J. R., Castro, M. A., Millán, D., Frangi, A. F., & Putman, C. M. (2005) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.593974 · Cited by 17
Adjacency-Based Data Reordering Algorithm for Acceleration of Finite Element Computations
Zhou, M., Sahni, O., Shephard, M. S., Carothers, C. D., & Jansen, K. E. (2010) · Scientific Programming · doi:10.1155/2010/273921 · Cited by 17
Friction factors in pulsed turbulent flow
Baird, M. H. I., Round, G. F., & Cardenas, J. N. (1971) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.5450490209 · Cited by 17
An Engineer's View of Prosthetic Heart Valve Performance
Roschke, E. J. (1973) · Biomaterials Medical Devices and Artificial Organs · doi:10.3109/10731197309118542 · Cited by 17
Computer simulation of arterial blood flow
Stergiopulos, N. (1990) · Iowa State University Digital Repository (Iowa State University) · doi:10.31274/rtd-180813-9416 · Cited by 17
Malvault, G. (2013) · theses.fr (ABES) · doi:10.70675/3745b2fbz02f0z44feza853z2408149bfd29 · Cited by 17
An experimental analysis of the characteristic behaviors of an impedance pump
Hickerson, A. I. (2005) · doi:10.7907/sqqk-fd11 · Cited by 17
Çarpınlıoğlu, M. Ö., & Özahi, E. (2013) · Flow Measurement and Instrumentation · doi:10.1016/j.flowmeasinst.2013.04.002 · Cited by 16
Tools to support mesh adaptation on massively parallel computers
Zhou, M., Xie, T., Seol, S., Shephard, M. S., Sahni, O., & Jansen, K. E. (2011) · Engineering With Computers · doi:10.1007/s00366-011-0218-x · Cited by 16
Hydrodynamic forces on steady and oscillating porous particles
Ollila, S. T. T., Ala-Nissilä, T., & Denniston, C. (2012) · Journal of Fluid Mechanics · doi:10.1017/jfm.2012.325 · Cited by 16
An in vitro test bench reproducing coronary blood flow signals
Chodzyński, K. J., Boudjeltia, K. Z., Lalmand, J., Aminian, A., Vanhamme, L., de Sousa, D. R., Gremmo, S., Bricteux, L., Renotte, C., Courbebaisse, G., et al. (2015) · BioMedical Engineering OnLine · doi:10.1186/s12938-015-0065-x · Cited by 16
Dilba, K., van Dam-Nolen, D. H. K., Korteland, S.-A., van der Kolk, A. G., Kassem, M., Bos, D., Koudstaal, P. J., Nederkoorn, P. J., Hendrikse, J., Kooi, M. E., et al. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.732646 · Cited by 16
Kumavat, P. S., Alimohammadi, S., & O’Shaughnessy, S. M. (2022) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2022.107790 · Cited by 16
Measuring brain beats: Cardiac‐aligned fast functional magnetic resonance imaging signals
Hermes, D., Wu, H., Kerr, A. B., & Wandell, B. A. (2022) · Human Brain Mapping · doi:10.1002/hbm.26128 · Cited by 16
Branching Exponents of Synthetic Vascular Trees Under Different Optimality Principles
Jessen, E., Steinbach, M. C., Debbaut, C., & Schillinger, D. (2023) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2023.3334758 · Cited by 16
Blood–wall fluttering instability as a physiomarker of the progression of thoracic aortic aneurysms
Zhao, T. Y., Johnson, E., Elisha, G., Halder, S., Smith, B. C., Allen, B. D., Markl, M., & Patankar, N. A. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01130-1 · Cited by 16
Shih, T., Huang, H., Wei, W.-C., & Horng, T. (2014) · International Communications in Heat and Mass Transfer · doi:10.1016/j.icheatmasstransfer.2014.01.019 · Cited by 16
Collette, M., Lefthériotis, G., & Humeau‐Heurtier, A. (2009) · Medical Physics · doi:10.1118/1.3213084 · Cited by 16
On the high frequency oscillatory tube flow of healthy human blood
Moyers-Gonzalez, M. A., Owens, R. G., & Fang, J. (2009) · Journal of Non-Newtonian Fluid Mechanics · doi:10.1016/j.jnnfm.2009.06.005 · Cited by 16
Measurement of Liquid Film Thickness via Light Absorption and Laser Tomography
Mendez, M. A., Németh, L., & Buchlin, J. ‐. (2016) · EPJ Web of Conferences · doi:10.1051/epjconf/201611402072 · Cited by 16
A novel, FFT-based one-dimensional blood flow solution method for arterial network
SAZONOV, I. A., & Nithiarasu, P. (2019) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-019-01146-0 · Cited by 16
Strain, strain rate, and mechanical power: An optimization comparison for oscillatory ventilation
Herrmann, J., Tawhai, M. H., & Kaczka, D. W. (2019) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3238 · Cited by 16
Ahmad, B., Hamdan, S., Alsaedi, A., & Ntouyas, S. K. (2021) · AIMS Mathematics · doi:10.3934/math.2021343 · Cited by 16
Effect of changes in the intravascular volume during hemodialysis on blood viscoelasticity
Metry, G., Adhikarla, R., Schneditz, D., Ronco, C., & Levin, N. W. (2011) · Indian Journal of Nephrology · doi:10.4103/0971-4065.82139 · Cited by 16
Impedance matching at arterial bifurcations
Brown, N. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90613-j · Cited by 16
Pulsating Flow for Mixing Intensification in a Twisted Curved Pipe
Timité, B., Jarrahi, M., Castelain, C., & Peerhossaini, H. (2009) · Journal of Fluids Engineering · doi:10.1115/1.4000556 · Cited by 16
Pulsatory Channel Flows with Arbitrary Pressure Gradients
Majdalani, J., & Chibli, H. A. (2002) · AIAA Theoretical Fluid Mechanics Conference · doi:10.2514/6.2002-2981 · Cited by 16
Computational Analysis on Stent Geometries in Carotid Artery: A Review
Paisal, M. S. A., Taib, I., & Ismail, A. E. (2017) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/165/1/012003 · Cited by 16
Yee, A. J., Sakurai, Y., Eskin, S. G., & McIntire, L. V. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9078-8 · Cited by 16
FLUID FLOW IN DISTENSIBLE VESSELS
Bertram, C. (2008) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2008.05047.x · Cited by 16
SELF-MIXING INTERFEROMETRY AND ITS APPLICATIONS IN NONINVASIVE PULSE DETECTION
Hast, J. T. (2003) · Cited by 16
Basic principles of electrohaemodynamics
Djordjevich, L., & Sadove, M. S. (1981) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(81)90101-1 · Cited by 16
Dependence of central airway resistance on frequency and tidal volume: a model study
Isabey, D., Chang, H. K., Delpuech, C., HARF, A., & Hatzfeld, C. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.61.1.113 · Cited by 16
Pressure-gated microfluidic memristor for pulsatile information processing
Barnaveli, A., Kamsma, T. M., Boon, W. Q., & van Roij, R. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.054057 · Cited by 15
Castro, M. A., Putman, C. M., & Cebral, J. R. (2011) · Journal of Physics Conference Series · doi:10.1088/1742-6596/332/1/012001 · Cited by 15
Modeling of Fluid Transport in Geothermal Research
Rennera, J., & Steeb, H. (2014) · Cited by 15
Simulation and prediction of endothelial cell adhesion modulated by molecular engineering
Kopacz, A. M., Liu, W. K., & Liu, S. Q. (2008) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2008.01.016 · Cited by 15
Venuta, I. D., Boghi, A., & Gori, F. (2017) · Numerical Heat Transfer Part A Applications · doi:10.1080/10407782.2017.1293985 · Cited by 15
Ponalagusamy, R., Selvi, R. T., & Padma, R. (2022) · The European Physical Journal Plus · doi:10.1140/epjp/s13360-022-02434-y · Cited by 15
DeePN$^2$: A Deep Learning-Based Non-Newtonian Hydrodynamic Model
Fang, L., Ge, P., Zhang, L., Weinan, E., & Lei, H. (2022) · Journal of Machine Learning · doi:10.4208/jml.220115 · Cited by 15
High resolution methods for scalar transport problems in compliant systems of arteries
Tavelli, M., Dumbser, M., & Casulli, V. (2013) · Applied Numerical Mathematics · doi:10.1016/j.apnum.2013.06.009 · Cited by 15
Prochnow, B. N., O’Reilly, O., Dunham, E. M., & Petersson, N. A. (2017) · Computers & Fluids · doi:10.1016/j.compfluid.2017.03.015 · Cited by 15
Effects of variable viscosity on pulsatile flow of blood in a tapered stenotic flexible artery
Mukhopadhyay, S., Mandal, M. S., & Mukhopadhyay, S. (2018) · Mathematical Methods in the Applied Sciences · doi:10.1002/mma.5355 · Cited by 15
McEvoy, J., Alimohammadi, S., & Persoons, T. (2019) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2019.109885 · Cited by 15
Forcing frequency effects on turbulence dynamics in pulsatile pipe flow
Cheng, Z., Jelly, T. O., Illingworth, S. J., Maruŝiĉ, I., & Ooi, A. S. H. (2020) · International Journal of Heat and Fluid Flow · doi:10.1016/j.ijheatfluidflow.2020.108538 · Cited by 15
Varble, N., Day, S. W., Phillips, D. B., Mix, D., Schwarz, K. Q., Illig, K. A., & Chandra, A. (2013) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2013.04.055 · Cited by 15
Schirmer, C. M., & Malek, A. M. (2011) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2011-010070 · Cited by 15
Boundary Conditions by Schwarz-Christoffel Mapping in Anatomically Accurate Hemodynamics
Boutsianis, E., Gupta, S., Boomsma, K., & Poulikakos, D. (2008) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9571-3 · Cited by 15
Tuning a lattice-Boltzmann model for applications in computational hemodynamics
Golbert, D. R., Blanco, P. J., Clausse, A., & Feijóo, R. A. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.07.023 · Cited by 15
Blythman, R., Persoons, T., Jeffers, N. M. R., & Murray, D. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/745/3/032044 · Cited by 15
Two-dimensional study of a rectangular cylinder with a forebody airtight screen at a small distance
Giachetti, A., Bartoli, G., & Mannini, C. (2019) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/j.jweia.2019.03.015 · Cited by 15
Introduction to Biofluid Mechanics
AYYASWAMY, P. S. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-405935-1.00016-2 · Cited by 16
Lee, Y.-U., Luo, J., Sprague, E. A., & Han, H. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9877-9 · Cited by 15
Meyerson, S. L., Moawad, J. A., Loth, F., Skelly, C. L., Bassiouny, H. S., McKinsey, J. F., Gewertz, B. L., & Schwartz, L. B. (2000) · Journal of Vascular Surgery · doi:10.1067/mva.2000.105957 · Cited by 15
Sud, V. K., von Gierke, H. E., Oestreicher, H. L., & Kaleps, I. (1983) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442632 · Cited by 15
A transfer function-based mathematical model of the fetal-placental circulation
Capper, W. L., Cowper, J. G., & Myers, L. J. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00658-0 · Cited by 15
Measurement and Utilization of In Vivo Blood-Pressure Transfer Functions of Dog and Chicken Aortas
Strano, J. J., Welkowitz, W., & Fich, S. (1972) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1972.324068 · Cited by 15
Gaussian process emulators for 1D vascular models
Melis, A. (2017) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York) · Cited by 15
Gas transport mechanisms during high-frequency ventilation
Scott, T. J. A., Jacob, C., Tingay, D. G., & Leontini, J. S. (2024) · Respiratory Research · doi:10.1186/s12931-024-03049-w · Cited by 14
Fast blood-flow simulation for large arterial trees containing thousands of vessels
Muller, A., Clarke, R., & Ho, H. (2016) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2016.1207170 · Cited by 14
Effects of low-Re pulsatile flow on friction characteristics in bare square array rod bundles
Ayodeji, A., Tan, S., Eltayeb, A., & Mi, Z. (2018) · Annals of Nuclear Energy · doi:10.1016/j.anucene.2018.06.033 · Cited by 14
Numerical Investigation of Turbulence in Abdominal Aortic Aneurysms
Rawat, D. S., Pourquie, M. J. B. M., & Poelma, C. (2019) · Journal of Biomechanical Engineering · doi:10.1115/1.4043289 · Cited by 14
Zeng, C., Deng, W. Y., Fan, J., & Zhang, Y. (2019) · Journal of Hydrology · doi:10.1016/j.jhydrol.2019.124295 · Cited by 14
Numerical Simulation of Tidal Breathing Through the Human Respiratory Tract
Azarnoosh, J., Sreenivas, K., & Arabshahi, A. (2020) · Journal of Biomechanical Engineering · doi:10.1115/1.4046005 · Cited by 14
Wei, L., Gong, H., He, H. Z., Yuan, D., Xing, D., & Pan, L. (2020) · Nuclear Engineering and Design · doi:10.1016/j.nucengdes.2020.110893 · Cited by 14
Boscheri, W., Chiozzi, A., Carlino, M. G., & Bertaglia, G. (2023) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2023.116140 · Cited by 14
Hu, J., Yang, S., & Fu, X. (2012) · Science China Technological Sciences · doi:10.1007/s11431-012-4873-y · Cited by 14
Goswami, P., Mandal, D. K., Manna, N. K., & Chakrabarti, S. (2014) · Heat and Mass Transfer · doi:10.1007/s00231-014-1334-0 · Cited by 14
Qi, P., Li, X., Qiu, F., Qiao, S., Tan, S., & Wang, X. (2020) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2020.110047 · Cited by 14
Panasenko, G. P., & Stavre, R. (2020) · Journal of Mathematical Fluid Mechanics · doi:10.1007/s00021-020-0484-8 · Cited by 14
Modeling of Fluid Transport in Geothermal Research
Renner, J., & Steeb, H. (2014) · Springer eBooks · doi:10.1007/978-3-642-27793-1_81-2 · Cited by 14
Metadata
- Authors
- Womersley, J. R.
- Corresponding author
- Womersley, J. R.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1955-03-28
- Volume
- 127
- Issue
- 3
- Pages
- 553-563
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- PMC
- PMC1365740
- OpenAlex
- W2067298651
- Cited by
- 1,835
- References
- 3
- Citations by year
- 2026: 59 · 2025: 77 · 2024: 61 · 2023: 88 · 2022: 82 · 2021: 85 · 2020: 68 · 2019: 85 · 2018: 63 · 2017: 62 · 2016: 65 · 2015: 53 · 2014: 100 · 2013: 63 · 2012: 57
- FWCI
- 6.91
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- The Journal of Physiology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Hematology › Blood properties and coagulation
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- arterial blood flow, velocity calculation, flow rate, viscous drag, pressure gradient, hemodynamics, blood viscosity
- MeSH terms
- Arteries, Blood Circulation, Cardiovascular System, Humans, Pressure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.