Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 230

The DOI matches its Crossref record.

Mechanical transmission in a Pacinian corpuscle. An analysis and a theory

Open access
Loewenstein, W. R., Skalak, R. · 1966 · The Journal of Physiology

Abstract

1. An analysis is made of the transmission of mechanical forces through the Pacinian corpuscle. In particular, forces are analysed which produce pressure differences at the centre of the corpuscle and lead to excitation of the sensory nerve ending. 2. The main structural elements in force transmission through the corpuscle are the lamellae, their interconnexions, and the interlamellar fluid. The two former provide the elastic elements and constraint for the fluid; and the latter, the viscous elements. The mechanical equivalent incorporating these elements is a system of dashpots (the lamellar surfaces and the interlamellar fluid) and springs (the lamellae and their interconnexions); it is a mechanical filter which suppresses low frequencies. The dynamic and static patterns of lamella displacements in the equivalent are in close agreement with those observed in Pacinian corpuscles. 3. Steady‐state and transient pressure fields were determined for the equivalent. Under static compression, only elastic forces exist in the corpuscle. Analysis shows that such forces are transmitted poorly from periphery to centre through the lamellated structure. The compliance of the lamellar interconnexions is so high in relation to that of the lamellae themselves, that most of the pressure load is carried by the outer lamellae. As a result, only a small fraction of the steady‐state pressure at the outer surface reaches the centre of the corpuscle where the sensory ending is located. This is the mechanical basis of receptor adaptation. 4. Under dynamic compression, viscous forces develop in the corpuscle; and these account for most of the pressure at times too early for development of elastic deformations. Analysis shows that such forces are transmitted well. For example, if a typical corpuscle of 500μ diameter is compressed by 20μ linearly during 2 msec, the pressure differences near to the centre of the corpuscle are initially as high as at the periphery, and stay within the same order throughout the process of compression. In general, pressure at the centre increases steeply with velocity of compression. This explains the marked velocity dependence of the generator response of the sensory ending. If, in the foregoing example, the 20μ compression is held fixed after 2 msec, the pressure differences at the centre fall abruptly to near zero with the onset of the static phase. The duration of pressure transients at the centre approximates that of the ‘active’ phase of the generator current of the sensory ending derived from experiments, as expected in a causal relationship: pressure difference → generator current. Taken together with the earlier experimental finding of marked prolongation of generator response in corpuscles partially stripped of lamellae (Loewenstein & Mendelson, 1965), this result warrants the conclusion that the mechanical filter action of the corpuscle is the rate‐limiting factor in generator response adaptation. 5. When the corpuscle is released from compression, energy stored in the elastic elements during compression is released and consumed in viscous flow. Thus, viscous pressure is produced anew. The magnitude of this pressure depends on the velocity of release. The pressure distribution is rotated by 90° with respect to that in compression; i.e. during release, compression occurs once again, but this time at right angles to the direction of initial compression. Experiments show that the sensory ending does not discriminate such a rotation; the polarity and order of magnitude of the generator response to compression in one plane are the same as in another. Analysis shows that considerable pressure differences may be developed at the centre of the corpuscle during releases at physiological velocities. For instance, in a passive return from a compression of 20μ, the pressure difference at the centre (and the generator current) is of the same order of magnitude as that in a compression of the velocity in 4. This accounts for the ‘off’‐response of the sensory ending in purely mechanical terms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1966.sp007827

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 230

Metadata

Authors
Loewenstein, W. R., & Skalak, R.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1966-01
Volume
182
Issue
2
Pages
346-378
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2058163164
Cited by
230
References
0
FWCI
6.90
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanical transmission in a Pacinian corpuscle. An analysis and a theory. https://app.cochat.ai/papers/10.1113/jphysiol.1966.sp007827
The paper
Loewenstein, W. R., & Skalak, R. (1966). Mechanical transmission in a Pacinian corpuscle. An analysis and a theory. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1966.sp007827

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.