The contrast sensitivity of retinal ganglion cells of the cat
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
1. Spatial summation within cat retinal receptive fields was studied by recording from optic‐tract fibres the responses of ganglion cells to grating patterns whose luminance perpendicular to the bars varied sinusoidally about the mean level. 2. Summation over the receptive fields of some cells (X‐cells) was found to be approximately linear, while for other cells (Y‐cells) summation was very non‐linear. 3. The mean discharge frequency of Y‐cells (unlike that of X‐cells) was greatly increased when grating patterns drifted across their receptive fields. 4. In twenty‐one X‐cells the relation between the contrast and spatial frequency of drifting sinusoidal gratings which evoked the same small response was measured. In every case it was found that the reciprocal of this relation, the contrast sensitivity function, could be satisfactorily described by the difference of two Gaussian functions. 5. This finding supports the hypothesis that the sensitivities of the antagonistic centre and surround summating regions of ganglion cell receptive fields fall off as Gaussian functions of the distance from the field centre. 6. The way in which the sensitivity of an X‐cell for a contrast‐edge pattern varied with the distance of the edge from the receptive field centre was determined and found to be consistent with the cell's measured contrast sensitivity function. 7. Reducing the retinal illumination produced changes in the contrast sensitivity function of an X‐cell which suggested that the diameters of the summating regions of the receptive field increased while the surround region became relatively ineffective.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In nature, early-stage retinal processing has also been observed, such as temporal filtering and motion-opponent channels (71–73), which compress information before being processed by the brain.”
From What if eye...? Computationally recreating vision evolution (2025) · cites this paper as [71]
Citations
Cites
DISCHARGE PATTERNS AND FUNCTIONAL ORGANIZATION OF MAMMALIAN RETINA
Kuffler, S. W. (1953) · Journal of Neurophysiology · doi:10.1152/jn.1953.16.1.37 · Cited by 2,609
Optical and retinal factors affecting visual resolution.
Campbell, F. W., & Green, D. G. (1965) · The Journal of Physiology · doi:10.1113/jphysiol.1965.sp007784 · Cited by 1,595 · cited 4×
“The contrast of the grating was standardized with a calibrated neutral-density filter (Campbell & Green, 1965).”
BackgroundMethodInfluentialSummation and inhibition in the frog's retina
Barlow, H. B. (1953) · The Journal of Physiology · doi:10.1113/jphysiol.1953.sp004829 · Cited by 896 · cited 3×
“This concentric arrangement of receptive fields seems to be universal in both the cat and spider monkey (Wiesel, 1960; Hubel & Wiesel, 1960) and has also been found in the frog (Barlow, 1953) and rabbit (Barlow, Hill & Levick, 1964).”
BackgroundMethodInfluentialTungsten Microelectrode for Recording from Single Units
Hubel, D. H. (1957) · Science · doi:10.1126/science.125.3247.549 · Cited by 849
Retinal ganglion cells responding selectively to direction and speed of image motion in the rabbit
Barlow, H. B., Hill, R. M., & Levick, W. R. (1964) · The Journal of Physiology · doi:10.1113/jphysiol.1964.sp007463 · Cited by 848 · cited 1×
“In the rabbit (Barlow et al. 1964) and squirrel (Cooper & Robson, 1966), retinal ganglion cells which respond selectively to the motion of patterns in some particular preferred direction are quite common.”
BackgroundChange of organization in the receptive fields of the cat's retina during dark adaptation
Barlow, H. B., Fitzhugh, R., & Kuffler, S. W. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005817 · Cited by 778 · cited 1×
“This can be interpreted as a disappearance of the effect of the antagonistic surround of the cell's receptive field at low light levels as described by Barlow et al. (1957) .”
BackgroundQuantitative analysis of cat retinal ganglion cell response to visual stimuli
Rodieck, R. W. (1965) · Vision Research · doi:10.1016/0042-6989(65)90033-7 · Cited by 764 · cited 6×
“We assume that each retinal ganglion cell is influenced by signals coming from elementary areas of its receptive field (photoreceptors) and that each receptive field is organized into an approximately circular central region with a concentric surround (Kuffler, 1953; Rodieck & Stone, 1965b).”
BackgroundMethodResultInfluentialTemporal and spatial summation in human vision at different background intensities
Barlow, H. B. (1958) · The Journal of Physiology · doi:10.1113/jphysiol.1958.sp005978 · Cited by 686 · cited 1×
“But psychophysical determinations of the threshold contrast for disks of various diameters (e.g.Barlow, 1958) show that there is no optimal diameter for a test patch.”
BackgroundSingle unit activity in striate cortex of unrestrained cats
Hubel, D. H. (1959) · The Journal of Physiology · doi:10.1113/jphysiol.1959.sp006238 · Cited by 575
ANALYSIS OF RECEPTIVE FIELDS OF CAT RETINAL GANGLION CELLS
Rodieck, R. W., & Stone, J. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.5.833 · Cited by 558
Cited by
Items 801–900 of 1,004
What simple and complex cells compute
Carandini, M. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2006.118976 · Cited by 46
“To test this hypothesis, they turned again to the approach that had demonstrated the linearity of X retinal cells (Enroth-Cugell & Robson, 1966).”
BackgroundMethodInfluentialLearning quadratic receptive fields from neural responses to natural stimuli
Rajan, K., Marre, O., & Tka\v{c}ik, G. (2012) · arXiv (Cornell University) · doi:10.1016/j.jphysparis.2012.12.001 · Cited by 29
“Although it has long been known that nonlinear integration exists in the retina and that ganglion cells can distinctly differ in whether they act linearly or nonlinearly (Enroth-Cugell and Robson, 1966), there are only few examples of quantitative assessments of the relevant nonlinearities.”
Victor, J. D., & Zemon, V. M. (1985) · Vision Research · doi:10.1016/0042-6989(85)90006-9 · Cited by 48
“Based on the known properties of X cells and Y cells (Enroth-Cugell and Robson, 1966; Hochstein and Shapley, 1976; Victor and Shapley, 1979; Kaplan and Shapley, 1982), it is probable that these patterns elicit virtually identical population responses from retinal ganglion cells and lateral…”
BackgroundThe Influence of Different Retinal Subcircuits on the Nonlinearity of Ganglion Cell Behavior
Hennig, M. H., Funke, K., & Wörgötter, F. (2002) · Journal of Neuroscience · doi:10.1523/jneurosci.22-19-08726.2002 · Cited by 47
“Two types of ganglion cells have been implemented, one type with a narrow receptive field (X-cells) and another type with a wide receptive field (Y-cells) (Enroth-Cugell and Robson, 1966), analogous to the morphological classification as and cells (Boycott and Wässle, 1974).”
BackgroundInfluentialChapter 10 Inhibitory GABAergic control of visual signals at the lateral geniculate nucleus
Norton, T. T., & Godwin, D. W. (1992) · Progress in brain research · doi:10.1016/s0079-6123(08)63615-8 · Cited by 47
Adaptation and dynamics in X-cells and Y-cells of the cat retina
Jakiela, H. G., Enroth‐Cugell, C., & Shapley, B. (1976) · Experimental Brain Research · doi:10.1007/bf00235001 · Cited by 47
“Cat retinal ganglion cells with concentric center and surround have been classified on the basis of their spatial summation properties (Enroth-Cugell and Robson, 1966).”
BackgroundSelf-citationNaito, T., Sadakane, O., Okamoto, M., & Sato, H. (2007) · Neuroscience · doi:10.1016/j.neuroscience.2007.08.001 · Cited by 49
Dark adaptation and receptive field organisation of cells in the cat lateral geniculate nucleus
Virsu, V., Lee, B. B., & Creutzfeldt, O. D. (1977) · Experimental Brain Research · doi:10.1007/bf00234823 · Cited by 46
“At low levels of retinal illuminance the power of the receptive field (RF) surround to antagonise centre responses decreases and the apparent size of RF centre increases (Barlow et al., 1957b; Rodieck and Stone, 1965; Enroth-Cugell and Robson, 1966; Gouras, 1967; Andrews and Hammond, 1970; Maffei et al., 1971; Cleland…”
BackgroundVisual motion and cortical velocity
Johnston, A., & Wright, M. J. (1983) · Nature · doi:10.1038/304436a0 · Cited by 46
Retinal physiology: Adapting to the changing scene
Shapley, R. M. (1997) · Current Biology · doi:10.1016/s0960-9822(06)00207-7 · Cited by 46
“Enroth-Cugell and Robson [9] devised this experiment as an indicator of X cells, because it is a test for linearity of signal summation: the zero-mean sine grating should have no effect on mean firing rate if retinal signals are summed linearly, as they are by X cells.”
Parallel Circuits from Cones to the On‐Beta Ganglion Cell
Cohen, E. D., & Sterling, P. (1992) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.1992.tb00901.x · Cited by 46
Distribution of small and medium‐sized ganglion cells in the cat's retina
Stone, J., & Keens, J. (1980) · The Journal of Comparative Neurology · doi:10.1002/cne.901920205 · Cited by 46
Kaneda, M., & Kaneko, A. (1991) · Neuroscience Research · doi:10.1016/0168-0102(91)90009-n · Cited by 46
Intensity-dependent spatial summation
Cornsweet, T. N., & Yellott, J. I. (1985) · Journal of the Optical Society of America A · doi:10.1364/josaa.2.001769 · Cited by 46
Masking by light and the sustained-transient dichotomy
Green, M. (1984) · Perception & Psychophysics · doi:10.3758/bf03205948 · Cited by 46
Direct identification of the cell bodies of Y-, X- and W-cells in the cats retina
Fukuda, Y., & Stone, J. (1975) · Vision Research · doi:10.1016/0042-6989(75)90249-7 · Cited by 46
Kageyama, G. H., & Wong‐Riley, M. (1985) · Journal of Comparative Neurology · doi:10.1002/cne.902420304 · Cited by 46
Weber, A. J., & Harman, C. D. (2008) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.07-1325 · Cited by 50
Marco, S. D., Nguyen, V. A., Bisti, S., & Protti, D. A. (2009) · Journal of Neuroscience · doi:10.1523/jneurosci.3854-09.2009 · Cited by 47
“…and inhibitory components of the RF are spatially mismatched, as opposed to control cells and to the classical RF model of RGCs (Rodieck, 1965; Enroth-Cugell and Robson, 1966) and that on average the degree of separation between the position of the peak of excitation and inhibition in DR/R…”
BackgroundAndolina, I. M., Jones, H. E., & Sillito, A. M. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00194.2012 · Cited by 47
Modelling spatial contrast sensitivity functions for chromatic and luminance-modulated gratings
Rovamo, J. M., Kankaanpää, M. I., & Kukkonen, H. T. (1999) · Vision Research · doi:10.1016/s0042-6989(98)00273-9 · Cited by 45
“…neural visual pathways can be assumed to result from subtractive lateral inhibition produced by the centre-surround antagonism of the receptive fields (e.g. Enroth-Cugell & Robson, 1966; Donner & Hemilä, 1996) producing attenuation at low spatial frequencies for luminance-modulated stimuli.”
BackgroundOn temporal codes and the spatiotemporal response of neurons in the lateral geniculate nucleus
Golomb, D., Kleinfeld, D., Reid, R. C., Shapley, R. M., & Shraiman, B. I. (1994) · Journal of Neurophysiology · doi:10.1152/jn.1994.72.6.2990 · Cited by 45
The Roles of Sustained (P) and Transient (M) Channels in Reading and Reading Disability
Breitmeyer, B. G. (1993) · Studies in visual information processing · doi:10.1016/b978-0-444-89949-1.50008-0 · Cited by 60
Magnussen, S. J., & Glad, A. (1975) · Experimental Brain Research · doi:10.1007/bf00234674 · Cited by 45
Prediction of flicker sensitivities from temporal three-pulse data
Bergen, J. R., & Wilson, H. R. (1985) · Vision Research · doi:10.1016/0042-6989(85)90163-4 · Cited by 45
Nonlinear systems analysis: comparison of white noise and sum of sinusoids in a biological system.
Victor, J. D. (1979) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.76.2.996 · Cited by 45
Kelly, D. H. (1972) · Handbook of sensory physiology · doi:10.1007/978-3-642-88658-4_11 · Cited by 45
The development of basic mechanisms of pattern vision: Spatial frequency channels
Banks, M. S., Stephens, B. R., & Hartmann, E. E. (1985) · Journal of Experimental Child Psychology · doi:10.1016/0022-0965(85)90080-3 · Cited by 45
“Thus, retinal ganglion and lateral geniculate cells are generally responsive to a fairly broad range of spatial frequencies (Derrington & Fuchs, 1979; Enroth-Cugell & Robson, 1966).”
BackgroundA Cognitive Approach for Object Discovery
Frintrop, S., García, G. M., & Cremers, A. B. (2014) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr.2014.404 · Cited by 47
“The latter fits better to human perception [7] and it achieved better performance also in our experiments.”
BackgroundHoriuchi, K., Ishihara, M., & Imanaka, K. (2017) · PLoS ONE · doi:10.1371/journal.pone.0184552 · Cited by 51
Linear Summation Underlies Direction Selectivity in Drosophila
Wienecke, C. F. R., Leong, J. C. S., & Clandinin, T. R. (2018) · Neuron · doi:10.1016/j.neuron.2018.07.005 · Cited by 43
“In particular, (1) the response amplitude varied sinusoidally with stimulus spatial phase; (2) across all stimulus spatial phases, the response amplitude was never zero (that is, there was no ‘‘null response,’’ as there would be in a linear non-DS system); and (3) the temporal phase of the response varied proportional…”
BackgroundLinear and nonlinear systems analysis of the visual system: Why does it seem so linear?
Shapley, R. M. (2008) · Vision Research · doi:10.1016/j.visres.2008.09.026 · Cited by 48
“8; Enroth-Cugell & Robson, 1966).”
InfluentialVisual motion integration by neurons in the middle temporal area of a New World monkey, the marmoset
Solomon, S. S., Tailby, C., Gharaei, S., Camp, A. J., Bourne, J. A., & Solomon, S. G. (2011) · The Journal of Physiology · doi:10.1113/jphysiol.2011.213520 · Cited by 47
“In each case, we fitted descriptive functions to the underlying data; we used a difference of Gaussians (Enroth-Cugell & Robson, 1966) to describe the spatial frequency tuning curve, a difference of exponentials (Derrington & Lennie, 1984) for temporal frequency, and a two-dimensional difference of…”
MethodGender differences in response to spatial frequency and stimulus orientation
Brabyn, L. A., & McGuinness, D. (1979) · Perception & Psychophysics · doi:10.3758/bf03199887 · Cited by 44
SPATIOTEMPORAL CONTRAST SENSITIVITY AND COLOUR VISION IN MULTIPLE SCLEROSIS
Travis, D., & Thompson, P. (1989) · Brain · doi:10.1093/brain/112.2.283 · Cited by 48
“However, this approach does not enable the identification of the site of any lesion because spatial and temporal frequency tuning is present at the level of the ganglion cells (Enroth-Cugell and Robson, 1966) as well as in the visual cortex (De Valois et al., 1982).”
The visible persistence of stimuli in stroboscopic motion
Farrell, J., Misha Pavel, C., & Sperling, G. (1990) · Vision Research · doi:10.1016/0042-6989(90)90058-s · Cited by 44
Contrast discrimination by the human visual system
Burton, G. J. (1981) · Biological Cybernetics · doi:10.1007/bf00326678 · Cited by 44
Visual and Language Processing Disorders are Concurrent in Dyslexia and Continue into Adulthood
Slaghuis, W. L., Twell, A. J., & Kingston, K. (1996) · Cortex · doi:10.1016/s0010-9452(96)80002-5 · Cited by 57
Neural models for sustained and ON-OFF units of insect lamina
Öğmen, H., & Gagné, S. (1990) · Biological Cybernetics · doi:10.1007/bf00202453 · Cited by 44
“Enroth-Cugell and Robson 1966; Kaneko 1973; Ratliff 1965; Schwartz 1974; Werblin and Dowling 1969).”
BackgroundSensory analysis in vision and audition
Legge, G. E., & Viemeister, N. F. (1988) · Behavioral and Brain Sciences · doi:10.1017/s0140525x00050032 · Cited by 44
Rowe, M. H., & Stone, J. (1976) · Experimental Brain Research · doi:10.1007/bf00241726 · Cited by 44
Alonso, J.-M., Yeh, C.-I., Weng, C., & Stoelzel, C. R. (2006) · Progress in brain research · doi:10.1016/s0079-6123(06)54001-4 · Cited by 43
“Wassle, 1981). One-half of these cells (53–57%) has small receptive fields and is classified as X and a much smaller proportion (2–4%) has larger receptive fields and is classified as Y ( Enroth-Cugell and Robson, 1966; Friedlander et al., 1979; Illing and Wassle, 1981).”
BackgroundSynaptic pathways that shape the excitatory drive in an OFF retinal ganglion cell
Buldyrev, I., Puthussery, T., & Taylor, W. R. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00924.2011 · Cited by 47
“These cells are likely homologues of the X or RGCs, studied extensively in the cat and other mammals (Boycott and Wässle 1974; Cleland et al. 1971; Enroth-Cugell and Robson 1966; Hochstein and Shapley 1976; Shapley and Victor 1978; Troy 1983; Vaney et al. 1981).”
BackgroundA Retina Inspired Model for Enhancing Visibility of Hazy Images
Zhang, X.-S., Gao, S., Li, C.-Y., & Li, Y. (2015) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2015.00151 · Cited by 45
“…most bipolar cells consists of two regions: a smaller excitatory center and a lager inhibitory annular surround (Werblin and Dowling, 1969a; Kaneko and Tachibana, 1983), which is commonly described by the “difference of Gaussian” (DOG) model (Rodieck and Stone, 1965; Enroth-Cugell and Robson, 1966).”
BackgroundThomas, J. G., & Sharp, P. B. (2019) · Clinical Psychological Science · doi:10.1177/2167702618810223 · Cited by 45
Nature of the maintained discharge of Q, X, and Y retinal ganglion cells of the cat
Robson, J. G., & Troy, J. B. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.002301 · Cited by 43
Self-citationGhosh, K., Sarkar, S., & Bhaumik, K. (2005) · Biological Cybernetics · doi:10.1007/s00422-005-0580-0 · Cited by 42
“…(DoG) model of the classical receptive field (CRF) of the ganglion cells (Rodieck K. Ghosh (B)· S. Sarkar · K. Bhaumik Microelectronics Division,Saha Institute of Nuclear Physics 1/AF Bidhannagar, Kolkata-700064, India E-mail: kuntal.ghosh@saha.ac.in and Stone 1965; Enroth-Cugell and Robson 1966).”
BackgroundNaito, J., & Chen, Y. (2004) · The Journal of Comparative Neurology · doi:10.1002/cne.11010 · Cited by 42
“…Rowe and Stone, 1977), which were classified according to characteristics such as receptive field properties, axonal conduction velocities, and level of maintained activity (Enroth-Cugell and Robson, 1966; Cleland et al., 1971; Fukada, 1971; Stone and Hoffmann; 1972, Stone and Fukuda, 1974).”
BackgroundGielen, C. C. A. M., Gisbergen, J. A. M. V., & Vendrik, A. J. H. (1982) · Biological Cybernetics · doi:10.1007/bf00344277 · Cited by 43
“Based on their responses to spatial counterphase gratings, all units from anaesthetized animals were classified as X-type according to the criterion of linear spatial summation (Enroth-Cugell and Robson, 1966; Hochstein and Shapley, 1976).”
MethodThe spike generating mechanism of cat retinal ganglion cells
Lankheet, M. J., Molenaar, J., & van de GRIND, W. A. (1989) · Vision Research · doi:10.1016/0042-6989(89)90037-0 · Cited by 43
Statistics of the maintained discharge of cat retinal ganglion cells.
Frishman, L. J., & Levine, M. W. (1983) · The Journal of Physiology · doi:10.1113/jphysiol.1983.sp014728 · Cited by 43
Alpha ganglion cells of the rabbit retina lose antagonistic surround responses under dark adaptation
Muller, J. F., & Dacheux, R. F. (1997) · Visual Neuroscience · doi:10.1017/s0952523800011512 · Cited by 43
Burke, W. J., Dreher, B., Michalski, A., Cleland, B. G., & Rowe, M. H. (1992) · Visual Neuroscience · doi:10.1017/s0952523800006362 · Cited by 48
Garey, L. J., & Blakemore, C. B. (1977) · Science · doi:10.1126/science.831287 · Cited by 42
Temporal aspects of spatial vision in the cat
Blake, R., & Camisa, J. M. (1977) · Experimental Brain Research · doi:10.1007/bf00235714 · Cited by 43
“It is well established that the visual pathways in the cat, especially from retina to cortex, are composed of two functionally distinct classes of neurons, termed X-cells and Y-cells, which display different spatio-temporal response properties (Enroth-Cugell and Robson, 1966; Cleland et al., 1971; Ikeda and Wright, 19…”
BackgroundMethodPantle, A. J. (1978) · Perception & Psychophysics · doi:10.3758/bf03206100 · Cited by 42
Organizational motifs for ground squirrel cone bipolar cells
Light, A., Zhu, Y., Shi, J., Saszik, S. M., Lindström, S., Davidson, L., Li, X., Chiodo, V. A., Hauswirth, W. W., Li, W., et al. (2012) · The Journal of Comparative Neurology · doi:10.1002/cne.23068 · Cited by 44
“Examples include the primate On and Off midget and parasol cells (Chichilnisky and Kalmar, 2002), cat On and Off X and Y cells (Enroth-Cugell and Robson, 1966), and the component On and Off responses of On–”
BackgroundYu, W., El-Danaf, R. N., Okawa, H., Pacholec, J., Matti, U., Schwarz, K., Odermatt, B., Dunn, F. A., Lagnado, L., Schmitz, F., et al. (2018) · Cell Reports · doi:10.1016/j.celrep.2018.10.089 · Cited by 44
“Previous recordings from RGCs revealed the presence of nonlinear computation at a spatial scale finer than that of the RGC’s receptive field center (Demb et al., 1999; Enroth-Cugell and Robson, 1966; Hochstein and Shapley, 1976; Petrusca et al., 2007; Stone and Pinto, 1993).”
BackgroundRegulation of Spatial Selectivity by Crossover Inhibition
Cafaro, J., & Rieke, F. M. (2013) · Journal of Neuroscience · doi:10.1523/jneurosci.4964-12.2013 · Cited by 51
“Nonlinear spatial integration, first observed in cat (Enroth-Cugell and Robson, 1966; Hochstein and Shapley, 1976), is a distinguishing feature of specific ganglion cell types in many retinas (for review, see Schwartz and Rieke, 2011).”
BackgroundA New Code for Contrast in the Primate Visual Pathway
Tailby, C., Solomon, S. G., Dhruv, N. T., Majaj, N. J., Sokol, S. H., & Lennie, P. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.5343-06.2007 · Cited by 42
A Simple Model of Optimal Population Coding for Sensory Systems
Doi, E., & Lewicki, M. S. (2014) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1003761 · Cited by 49
“This prediction has not been tested directly because, to the best of our knowledge, all physiological measurements from RGCs with different light levels have carried out either in cat [15,54,55] or rabbit [67] retinas, where the reported adaptive changes were marginal.”
BackgroundInfluentialDynamic Visual Perception of Dyslexic Children
Fischer, B., Hartnegg, K., & Mokler, A. (2000) · Perception · doi:10.1068/p2666b · Cited by 42
Neural model of first-order and second-order motion perception and magnocellular dynamics
Baloch, A. A., Grossberg, S., Mingolla, E., & Nogueira, C. A. M. (1999) · Journal of the Optical Society of America A · doi:10.1364/josaa.16.000953 · Cited by 46
Disordered spatiotemporal processing in schizophrenics
Schwartz, B. D., McGinn, T., & Winstead, D. K. (1987) · Biological Psychiatry · doi:10.1016/0006-3223(87)90200-9 · Cited by 43
“…to derive their characteristic responses from spatiotemporal properties of their constituent neurons, the “x” cells and “Y” cells, which have been identified in single unit recordings from the retina (Enroth-Cugell and Robson 1966) and from the lateral geniculate nucleus (Hoffman et al. 1972).”
BackgroundWillmore, B. D. B., & Smyth, D. (2003) · Network Computation in Neural Systems · doi:10.1088/0954-898x/14/3/309 · Cited by 42
THE CORTICAL MAGNIFICATION FACTOR AND PHOTOPIC VISION
Pointer, J. S. (1986) · Biological reviews/Biological reviews of the Cambridge Philosophical Society · doi:10.1111/j.1469-185x.1986.tb00463.x · Cited by 42
Vidyasagar, T. R., & Heide, W. (1984) · Experimental Brain Research · doi:10.1007/bf00231146 · Cited by 45
“Since X cells always give a modulated response to moving sine wave gratings (Enroth-Cugell and Robson 1966), we used the amplitude of modulation of the first (fundamental) harmonic component as a measure of the response, after doing a fast Fourier transform of the PSTH.”
MethodSaito, H. (1983) · Vision Research · doi:10.1016/0042-6989(83)90105-0 · Cited by 42
“X-cells were init~~~ify distinguished from Y-cells by their responses to a grating stimulus (Enroth-Cugell and Robson, 1966).”
BackgroundCenter-surround interactions in two types of on-center retinal ganglion cells in the cat
Hickey, T. E., Winters, R. W., & Pollack, J. G. (1973) · Vision Research · doi:10.1016/0042-6989(73)90010-2 · Cited by 42
Computing Optical Flow in the Primate Visual System
Wang, H. T., Mathur, B., & Koch, C. (1989) · Neural Computation · doi:10.1162/neco.1989.1.1.92 · Cited by 45
“... network extracts the optical flow in two stages (Fig. 1). In a preliminary stage, the time-varying image Z(i,j) is projected onto the retina and relayed to cortex via two neuronal pathways providing information as to the spatial location of image features (S neurons) and temporal changes in these features (T neuro…”
BackgroundGradient detection and contrast transfer by the human eye
van der Wildt, G. J., Keemink, C. J., & van den Brink, G. (1976) · Vision Research · doi:10.1016/0042-6989(76)90242-x · Cited by 42
Bio-inspired XYW parallel pathway edge detection network
Pang, X., Lin, C., Li, F., & Pan, Y. (2023) · Expert Systems with Applications · doi:10.1016/j.eswa.2023.121649 · Cited by 43
Transmission of colour and acuity signals by parvocellular cells in marmoset monkeys
Martin, P. R., Blessing, E., Buzás, P., Szmajda, B. A., & Forte, J. D. (2011) · The Journal of Physiology · doi:10.1113/jphysiol.2010.194076 · Cited by 41
Local and Global Contrast Adaptation in Retinal Ganglion Cells
Garvert, M. M., & Gollisch, T. (2013) · Neuron · doi:10.1016/j.neuron.2012.12.030 · Cited by 49
Temporal whitening: Transient noise perceptually equalizes the 1/f temporal amplitude spectrum
Cass, J., Alais, D., Špehar, B., & Bex, P. J. (2009) · Journal of Vision · doi:10.1167/9.10.12 · Cited by 43
“Mechanistic interpretations—High temporal frequency-biased responses (Derrington & Fuchs, 1978; Enroth-Cugell & Robson, 1966; Dawis, Shapley, Kaplan, & Tranchina, 1984; Hochstein & Shapley, 1976) and adaptation effects have been observed in magnocellular layers of primate retina (Baccus & Meister,…”
BackgroundTroncoso, X. G., Macknik, S. L., & Martínez‐Conde, S. (2005) · Perception · doi:10.1068/p5383 · Cited by 41
Pairwise-Comparison-Based Rank Learning for Benchmarking Image Restoration Algorithms
Hu, B., Li, L., Liu, H., Lin, W., & Qian, J. (2019) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2019.2894958 · Cited by 45
“retina [54], [55].”
Reconciling Color Vision Models With Midget Ganglion Cell Receptive Fields
Patterson, S. S., Neitz, M., & Neitz, J. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00865 · Cited by 48
Ghosh, K., Sarkar, S., & Bhaumik, K. (2005) · Biological Cybernetics · doi:10.1007/s00422-005-0038-4 · Cited by 41
“E-mail: kuntal.ghosh@saha.ac.in K. Bhaumik WBUT, BF-142, Kolkata 700064, India are inherently contrast estimators (Enroth-Cugell and Robson 1966).”
BackgroundTanaka, H., & Ohzawa, I. (2008) · Journal of Neurophysiology · doi:10.1152/jn.90749.2008 · Cited by 45
The coarse-to-fine hypothesis revisited: Evidence from neuro-computational modeling
Mermillod, M., Guyader, N., & Chauvin, A. (2004) · Brain and Cognition · doi:10.1016/j.bandc.2004.08.035 · Cited by 47
“At a neurophysiological level, Enroth-Cugell and Robson (1966) reported spatiotemporal characteristics of X (responding to high-resolution stimuli) and Y (responding to low-resolution stimuli) retinal ganglion cells showing that, since retinal processes, there is a difference between high- and…”
BackgroundVisual Response Properties of Burst and Tonic Firing in the Mouse Dorsal Lateral Geniculate Nucleus
Grubb, M. S., & Thompson, I. D. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00445.2004 · Cited by 42
High visual contrast sensitivity in the young human infant.
Norcia, A. M., Tyler, C. W., & Hamer, R. D. (1988) · PubMed · Cited by 46
Breitmeyer, B. G. (1973) · Vision Research · doi:10.1016/0042-6989(73)90163-6 · Cited by 46
Burke, W. J., Burne, J. A., & Martin, P. R. (1985) · The Journal of Physiology · doi:10.1113/jphysiol.1985.sp015731 · Cited by 41
The neurobiology of reading difficulties
Stein, J. F. (2000) · Prostaglandins Leukotrienes and Essential Fatty Acids · doi:10.1054/plef.2000.0200 · Cited by 50
“The ganglion cells whose axons carry visual signals from the retina to the rest of the brain can be divided into two main types: 90% are known as parvo cells from their small cell bodies and restricted dendritic spread.(9,10) These are responsible for colour and fine detail.”
BackgroundSpatial receptive-field structure of cat retinal W cells
Rowe, M. H., & Cox, J. F. (1993) · Visual Neuroscience · doi:10.1017/s0952523800005459 · Cited by 41
Cleland, B. G., & Enroth‐Cugell, C. (1966) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1966.tb03438.x · Cited by 41
Self-citationPantle, A. J., Lehmkuhle, S., & Caudill, M. (1978) · Perception · doi:10.1068/p070261 · Cited by 42
Meridional Differences in Temporal Resolution
Schwartz, B. D., Winstead, D. K., & May, J. G. (1982) · Perception · doi:10.1068/p110025 · Cited by 41
Schwartz, B. (2001) · Frontiers in bioscience · doi:10.2741/schwartz · Cited by 40
“The M pathway is subserved by large receptive field cells analogous to “Y” cells, identified in animal studies (14).”
BackgroundTong, F., Harrison, S. A., Dewey, J. A., & Kamitani, Y. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.08.005 · Cited by 40
“Such differences in orientation discrimination would be expected due to the decline in spatial resolution found with increasing eccentricity in both the retina and cortex (De Valois et al., 1982; Enroth-Cugell and Robson, 1966; Hilz and Cavonius, 1974).”
Hallum, L. E., Shooner, C., Kumbhani, R. D., Kelly, J. G., García‐Marín, V., Majaj, N. J., Movshon, J. A., & Kiorpes, L. (2017) · Journal of Neuroscience · doi:10.1523/jneurosci.0449-17.2017 · Cited by 40
“DoGE is commonly used to model the spatial organization of the retinal ganglion cell’s RF to luminance variations (Rodieck and Stone, 1965; Enroth-Cugell and Robson, 1966).”
MethodJohnson, K. P., Zhao, L., & Kerschensteiner, D. (2018) · Cell Reports · doi:10.1016/j.celrep.2018.01.037 · Cited by 42
“These properties of PixON-RGCs are reminiscent of X/beta RGCs in cats, rabbits, and guinea pigs (Enroth-Cugell and Robson, 1966; Demb et al., 2001; Cleland and Levick, 1974; Roska et al., 2006), and to midget RGCs in primates (Crook et al., 2011; Sinha et al., 2017).”
BackgroundFurther Observations on the Role of Nitric Oxide in the Feline Lateral Geniculate Nucleus
Cudeiro, J., Rivadulla, C., Rodríguez, R., Martínez‐Conde, S., Martínez, L. M., Grieve, K. L., & Acuña, C. (1996) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.1996.tb01175.x · Cited by 41
“…of the response to standing contrast over the receptive field centre, the presence or absence of a shift effect, the strength of surround antagonism and size of receptive field centre for a given eccentricity (Enroth-Cugell and Robson, 1967; Cleland et al., 1971; Derrington and Fuchs, 1979).”
BackgroundBaker, G. E., Thompson, I. D., Krug, K., Smyth, D., & Tolhurst, D. J. (1998) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.1998.00276.x · Cited by 42
“In fact, cat retinal X- and Y-cells differ in their spatial-frequency tuning in just the way needed to explain the difference in optimal spatial-frequency in areas 17 and 18: cat X-cells respond optimally to higher spatial frequencies than Y-cells (Enroth-Cugell & Robson, 1966; Clelandet al., 1979).”
BackgroundInfluentialHuman colour discrimination based on a non-parvocellular pathway
Trościanko, T., Davidoff, J. B., Humphreys, G., Landis, T., Fahle, M. W., Greenlee, M. W., Brugger, P., & Phillips, W. A. (1996) · Current Biology · doi:10.1016/s0960-9822(02)00453-0 · Cited by 40
Independent Processing of Visual form and Motion
Krumhansl, C. L. (1984) · Perception · doi:10.1068/p130535 · Cited by 40
Closing the loop: detection and pursuit of a moving object by a moving observer
Nordlund, P., & Uhlin, T. (1996) · Image and Vision Computing · doi:10.1016/0262-8856(95)01051-3 · Cited by 41
“Several authors argue for the existence of separate channels for motion andstationary objects, e.g. (Enroth-Cugell and Robson, 1966; Tolhurst, 1973; Yantis andJonides, 1984) cited in (McLeod et al., 1991).”
BackgroundMotion detection in spatio-temporal space
Liou, S.-P., & Jain, R. (1989) · Computer Vision Graphics and Image Processing · doi:10.1016/0734-189x(89)90134-5 · Cited by 42
Metadata
- Authors
- Enroth-Cugell, C., & Robson, J. G.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1966-12
- Volume
- 187
- Issue
- 3
- Pages
- 517-552
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- PMC
- PMC1395960
- OpenAlex
- W1988849438
- Cited by
- 2,625
- References
- 27
- Citations by year
- 2026: 27 · 2025: 21 · 2024: 22 · 2023: 33 · 2022: 34 · 2021: 49 · 2020: 41 · 2019: 39 · 2018: 39 · 2017: 46 · 2016: 41 · 2015: 58 · 2014: 48 · 2013: 43 · 2012: 51
- FWCI
- 8.72
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- The Journal of Physiology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Visual perception and processing mechanisms
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neuropharmacology Research
- Keywords
- retinal ganglion cells, contrast sensitivity function, spatial summation, receptive fields, X-cells, Y-cells, center-surround antagonism, drifting sinusoidal gratings, cat retina
- MeSH terms
- Animals, Cats, Models, Neurological, Optic Nerve, Photic Stimulation, Retinal Ganglion Cells, Visual Fields, Contrast Sensitivity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.