The effect of withdrawal of visual presentation of errors upon the frequency spectrum of tremor in a manual task
Open accessThe DOI matches its Crossref record.
Abstract
1. When a subject attempts to exert a steady pressure on a joystick he makes small unavoidable errors which, irrespective of their origin or frequency, may be called tremor. 2. Frequency analysis shows that low frequencies always contribute much more to the total error than high frequencies. If the subject is not allowed to check his performance visually, but has to rely on sensations of pressure in the finger tips, etc., the error power spectrum plotted on logarithmic co‐ordinates approximates to a straight line falling at 6 db/octave from 0·4 to 9 c/s. In other words the amplitude of the tremor component at each frequency is inversely proportional to frequency. 3. When the subject is given a visual indication of his errors on an oscilloscope the shape of the tremor spectrum alters. The most striking change is the appearance of a tremor peak at about 9 c/s, but there is also a significant increase of error in the range 1‐4 c/s. The extent of these changes varies from subject to subject. 4. If the 9 c/s peak represents oscillation of a muscle length‐servo it would appear that greater use is made of this servo when positional information is available from the eyes than when proprioceptive impulses from the limbs have to be relied on.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Physiological and pathological tremors and rhythmic central motor control
McAuley, J. H. (2000) · Brain · doi:10.1093/brain/123.8.1545 · Cited by 509
Noise, information transmission, and force variability.
Slifkin, A. B., & Newell, K. M. (1999) · Journal of Experimental Psychology Human Perception & Performance · doi:10.1037//0096-1523.25.3.837 · Cited by 394
Lippold, O. C. J. (1970) · The Journal of Physiology · doi:10.1113/jphysiol.1970.sp009018 · Cited by 286
McAuley, J. H., Rothwell, J. C., & Marsden, C. D. (1997) · Experimental Brain Research · doi:10.1007/pl00005662 · Cited by 285
Motor Neuron Pools of Synergistic Thigh Muscles Share Most of Their Synaptic Input
Laine, C. M., Martinez-Valdes, E., Falla, D., Mayer, F., & Farina, D. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.0240-15.2015 · Cited by 173
“The neural drive in the 6–12 Hz frequency range is associated with physiological tremor and may partly stemfromoscillationsofexcitationaroundtheIaafferent feedback loop (Sutton and Sykes, 1967; Lippold, 1970; Hagbarth and Young, 1979; Young and Hagbarth, 1980; Erimaki and Christakos, 1999, 2008; Christakos et al., 200…”
BackgroundThe effects of load and force on tremor at the normal human elbow joint
Joyce, G. C., & Rack, P. M. H. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010615 · Cited by 167
Metadata
- Authors
- Sutton, G. G., & Sykes, K.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1967-05
- Volume
- 190
- Issue
- 2
- Pages
- 281-293
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2066649245
- Cited by
- 59
- References
- 0
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.