Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

The effects of load and force on tremor at the normal human elbow joint

Open access
Joyce, G. C., Rack, Peter M. H. · 1974 · The Journal of Physiology

Abstract

1. Spontaneous flexion‐extension tremor of the elbow was recorded in normal human subjects while they exerted a flexing force against different loads. 2. Increases in the flexing force up to ½ or ¾ of the subject's maximum were accompanied by increases in the amplitude of the tremor. A further increase to very large forces was associated with a decrease in tremor. 3. When the subject flexed against a spring, the frequency of the tremor was related to the properties of the spring; with increasingly stiff springs the tremor frequency increased up to about 12 Hz. With the stiffest springs, however, the tremor became irregular and very small in amplitude. 4. Weights added to the limb at the wrist reduced the frequency of tremor. 5. By using appropriate combinations of spring and mass, the principal tremor frequency could be adjusted between 2 and 12 Hz, higher in some subjects. Within this range the frequency 2 was approximately proportional to the spring stiffness/mass, just as it is in a spring‐mass system, though the forearm provided some of this mass, and some of the spring‐like resistance was in the flexor muscles. 6. When by suitable loading the tremor frequency was brought between 8 and 12 Hz, and the subject forcibly flexed his elbow, the tremor became regular and large in amplitude. This was a form of limited instability in the stretch reflex which arose because a powerful reflex response to extension of the elbow acted back on the flexor muscles after a delay. 7. When the limb was so loaded that its natural frequency was outside this 8–12 Hz range, it behaved as a filter, and in response to any disturbing noise it oscillated mainly at frequencies close to the natural frequencies of either the mechanical system or the stretch reflex. 8. This filtering function of the limb with its stretch reflex probably plays an important part in the control of normal movement and tremor. 9. The large flexing forces that were here associated with vigorous tremor normally occur when a limb supports a large mass. Such a mass would give the mechanical system within the limb a low natural frequency; inconveniently large oscillations in the 8–12 Hz range would therefore seldom occur.

Overview

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1974.sp010615

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 15 references

Cited by

See all 167

Metadata

Authors
Joyce, G. C., & Rack, P. M. H.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1974-07
Volume
240
Issue
2
Pages
375-396
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W1989458918
Cited by
167
References
15
Citations by year
2026: 2 · 2025: 3 · 2024: 1 · 2022: 2 · 2021: 1 · 2020: 2 · 2019: 1 · 2018: 1 · 2017: 2 · 2016: 6 · 2015: 1 · 2014: 6 · 2013: 4 · 2012: 1
FWCI
3.96
Type
journal article
Language
en
Open access
Locations
  • The Journal of Physiology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Engineering › Biomedical Engineering › Mechanics and Biomechanics Studies
Keywords
tremor frequency, tremor amplitude, mass-spring system, natural frequencies, stretch reflex, flexor muscles, tremor filtering, motor control
MeSH terms
Adolescent, Adult, Biomechanical Phenomena, Child, Elbow, Physical Exertion, Female, Forearm, Humans, Male, Middle Aged, Muscles, Reflex, Wrist

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effects of load and force on tremor at the normal human elbow joint. https://app.cochat.ai/papers/10.1113/jphysiol.1974.sp010615
The paper
Joyce, G. C., & Rack, P. M. H. (1974). The effects of load and force on tremor at the normal human elbow joint. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1974.sp010615

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.