Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 355

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Motor unit types of cat triceps surae muscle

Open access
Burke, Robert E.·1967·The Journal of Physiology

Abstract

1. Motor units, defined as including a motoneurone (cell body, dendrites and axon) plus the muscle unit innervated, have been examined in the triceps surae motor pool of pentobarbital anaesthetized cats. 2. The technique of intracellular stimulation and recording which was used permitted measurement of the axonal conduction velocity, post‐spike hyperpolarization duration and input resistance of individual motoneurones, and the correlation of these properties with the characteristics of the twitch and tetanus responses of the muscle unit innervated by the cell elicited by direct intracellular stimulation. 3. On the basis of muscle unit speed of contraction, motor units were divided into two groups: (a) fast twitch, or F, type with twitch time to peak (TwTp) less than or equal to 30 msec, and (b) slow twitch, or S, type with TwTp of 40 msec or greater. The twitch tensions (TwTen) produced by type F units were significantly larger (median value = 18 g) than the tensions generated by type S units (TwTen median value = 1·6 g). Type F muscle units had much higher tetanus fusion frequencies (median = 85 pulses/sec) than the S type (median 25 pulses/sec), and tended to have smaller tetanus to twitch tension ratios (Tet/Tw) (median = 2·6) than type S units (median = 5·4). 4. The gastrocnemius heads contained a mixture of F and S types of muscle units, the proportions found being about 3 to 1 respectively. Units encountered in the soleus muscle were uniformly of type S. The characteristics of gastrocnemius and soleus type S motor units were not identical but appeared to represent quantitative differences in units of the same qualitative type. 5. Motoneurones innervating type F muscle units had faster axonal conduction velocities, shorter post‐spike hyperpolarizations and lower input resistances than those supplying type S units. However, no combination of motoneurone properties alone was sufficient to separate unambiguously types F and S motor units.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1967.sp008348

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 355

Metadata

Authors
Burke, R. E.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1967-11
Volume
193
Issue
1
Pages
141-160
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2049214134
Cited by
355
References
2
FWCI
15.29
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Motor unit types of cat triceps surae muscle. https://app.cochat.ai/papers/10.1113/jphysiol.1967.sp008348
The paper
Burke, R. E. (1967). Motor unit types of cat triceps surae muscle. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1967.sp008348

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.