The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Conduction failure in myelinated and non‐myelinated axons at low temperatures
Open accessAbstract
1. The effects of low temperature on conduction in single myelinated and non‐myelinated axons of the feline saphenous nerve were examined and compared. Nerves were cooled by a conventional thermode, but thermal gradients were minimized by an insulating layer of agar‐saline gel over the nerve and the face of the thermode. 2. The mean blocking temperature of thirty‐one non‐myelinated axons, 2·7° C, was significantly lower than that of 111 myelinated axons, 7·2° C. No evidence for a differential block of myelinated axons according to their normal conduction velocity could be demonstrated. 3. Reductions in the proportional conduction velocities of both myelinated and non‐myelinated axons were nearly identical between 17 and 37° C. However, below 17° C the rate at which the proportional conduction velocity of the non‐myelinated axons fell during cooling was significantly less than for the myelinated axons and was sufficient to account for their lower blocking temperatures. As a result, critical minimum conduction velocities were reached at higher temperatures in myelinated axons than in non‐myelinated axons. 4. The conduction velocity of successive impulses in a train slowed progressively to a constant value which depended on the frequency of stimulation. Consequently, the early impulses were separated by intervals that exceeded those between stimuli and were not affected by temperatures that blocked later impulses. The pattern of block was consistent with an increasing refractoriness of the axons as the temperature fell. 5. The maximal frequency of discharge that myelinated axons could carry at temperatures between normal and 12° C was related directly to fibre size. Non‐myelinated axons could conduct low frequency trains of impulses at temperatures that blocked such activity in myelinated axons. In all axons, high frequency trains of impulses could be completely blocked at temperatures which permitted lower frequency trains to pass uninterrupted. 6. Hysteresis in the blocking temperatures of axons was related to the hysteresis in their conduction velocities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tension receptors in the stomach and the urinary bladder
Iggo, A. (1955) · The Journal of Physiology · doi:10.1113/jphysiol.1955.sp005327 · Cited by 510
Self-citationReceptors in the trachea and bronchi of the cat
Widdicombe, J. G. (1954) · The Journal of Physiology · doi:10.1113/jphysiol.1954.sp005034 · Cited by 465
LOCATION OF POSTSYNAPTIC INHIBITORY SYNAPSES ON HIPPOCAMPAL PYRAMIDS
Andersen, P., Eccles, J. C., & Lyning, Y. (1964) · Journal of Neurophysiology · doi:10.1152/jn.1964.27.4.592 · Cited by 461
A quantitative study of cutaneous receptors and afferent fibres in the cat and rabbit
Brown, A. G., & Iggo, A. (1967) · The Journal of Physiology · doi:10.1113/jphysiol.1967.sp008390 · Cited by 370
Self-citationCutaneous mechanoreceptors with afferent C fibres
Iggo, A. (1960) · The Journal of Physiology · doi:10.1113/jphysiol.1960.sp006491 · Cited by 287
Self-citationPaintal, A. S. (1965) · The Journal of Physiology · doi:10.1113/jphysiol.1965.sp007687 · Cited by 228
UNMEDULLATED FIBERS ORIGINATING IN DORSAL ROOT GANGLIA
Gasser, H. S. (1950) · The Journal of General Physiology · doi:10.1085/jgp.33.6.651 · Cited by 207
Howarth, J. V., Keynes, R. D., & Ritchie, J. M. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008434 · Cited by 207
Iggo, A. (1958) · The Journal of Physiology · doi:10.1113/jphysiol.1958.sp006002 · Cited by 190
Self-citationGASTRO‐INTESTINAL TENSION RECEPTORS WITH UNMYELINATED AFFERENT FIBRES IN THE VAGUS OF THE CAT
Iggo, A. (1957) · Quarterly Journal of Experimental Physiology and Cognate Medical Sciences · doi:10.1113/expphysiol.1957.sp001228 · Cited by 182
Self-citation
Cited by
Rácz, I., & Zimmer, A. (2006) · Standards of Mouse Model Phenotyping · doi:10.1002/9783527611942.ch9 · Cited by 1,659
Le Bars, D., Gozariu, M., & Cadden, S. W. (2001) · Pharmacological Reviews · doi:10.1016/s0031-6997(24)01514-x · Cited by 1,459
Afferent vagal C fibre innervation of the lungs and airways and its functional significance
Coleridge, J. C. G., & Coleridge, H. M. (1984) · Reviews of Physiology, Biochemistry and Pharmacology · doi:10.1007/bfb0027715 · Cited by 712
Shahani, B. T., Halperin, J. J., Boulu, P., & Cohen, J. (1984) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.47.5.536 · Cited by 605
Debanne, D., Campanac, E., Bialowas, A., Carlier, E., & Alcaraz, G. (2011) · Physiological Reviews · doi:10.1152/physrev.00048.2009 · Cited by 571
Ultrasound Neuromodulation: A Review of Results, Mechanisms and Safety
Blackmore, J., Shrivastava, S., Sallet, J., Butler, C. R., & Cleveland, R. O. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.12.015 · Cited by 556
Cutaneous thermoreceptors in primates and sub‐primates
Iggo, A. (1969) · The Journal of Physiology · doi:10.1113/jphysiol.1969.sp008701 · Cited by 353
Self-citationThermoreceptors and thermosensitive afferents
Schepers, R. J., & Ringkamp, M. (2010) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2009.10.003 · Cited by 350
Reflexes Evoked from Tracheobronchial Tree and Lungs
Coleridge, H. M., & Coleridge, J. C. G. (1986) · Comprehensive Physiology · doi:10.1002/cphy.cp030212 · Cited by 348
Lipid metabolism in myelinating glial cells: lessons from human inherited disorders and mouse models
Chrast, R., Saher, G., Nave, K.-A., & Verheijen, M. H. G. (2011) · Journal of Lipid Research · doi:10.1194/jlr.r009761 · Cited by 314
Afferent G Units Responding to Mechanical, Thermal and Chemical Stimuli in Human Non‐Glabrous Skin
Torebjörk, H. E. (1974) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1974.tb05755.x · Cited by 299
Effects of temperature on neuromuscular electrophysiology
Rutkove, S. B. (2001) · Muscle & Nerve · doi:10.1002/mus.1084 · Cited by 288
Visual activity in area V2 during reversible inactivation of area 17 in the macaque monkey
Girard, P., & Bullier, J. (1989) · Journal of Neurophysiology · doi:10.1152/jn.1989.62.6.1287 · Cited by 179
Electrical stimulation of peripheral nerve
Swett, J. E., & Bourassa, C. M. (1981) · Electrical Stimulation Research Techniques · doi:10.1016/b978-0-12-547440-5.50016-4 · Cited by 39
Functional Properties of C-Low Threshold Mechanoreceptors (C-LTMRs) in Nonhuman Mammals
Pitcher, M., Le Pichon, C. E., & Chesler, A. (2016) · Affective Touch and the Neurophysiology of CT Afferents · doi:10.1007/978-1-4939-6418-5_2 · Cited by 12
Metadata
- Authors
- Franz, D. N., & Iggo, A.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1968-12
- Volume
- 199
- Issue
- 2
- Pages
- 319-345
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1981413880
- Cited by
- 267
- References
- 17
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.