The recovery of resting potential and input resistance in sheep heart injured by knife or laser
Open accessThe DOI matches its Crossref record.
Abstract
1. A lesion 100 μ in diameter with well‐defined boundaries was made with a laser in Purkinje fibres from sheep hearts. The membrane potential and the input resistance recorded in the intact tissue at about 0·5 mm from the edge of the lesion were found to drop at the instant of injury. The corresponding decrease of input resistance fits quantitatively the transmission line theory applied to a cable terminated by a short circuit at the lesion. 2. The input resistance and the membrane potential were found to rise simultaneously during healing‐over. The membrane potential returned to its original level within 1 min. By then, the input resistance had settled either to the same value as before injury, or to a higher value matching quantitatively the theoretical resistance of a cable terminated by an infinite resistance at the lesion. 3. Neither membrane potential nor input resistance recovered in calcium‐free solutions. But healing‐over rapidly occurred when calcium was added to solutions that might otherwise differ widely in composition. 4. The transmission line model fits all observations if it is assumed that the injury causes a leak or short circuit in the ‘cable’ that is soon closed, or rendered open circuit, by the development of a new diffusion barrier in the presence of calcium ions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The lysosome: from waste bag to potential therapeutic target
Appelqvist, H., Wäster, P., Kågedal, K., & Öllinger, K. (2013) · Journal of Molecular Cell Biology · doi:10.1093/jmcb/mjt022 · Cited by 772
Kléber, A. G., Janse, M. J., van Capelle, F. J., & Durrer, D. (1978) · Circulation Research · doi:10.1161/01.res.42.5.603 · Cited by 416
Electrical properties of individual cells isolated from adult rat ventricular myocardium.
Powell, T., Terrar, D. A., & Twist, V. W. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013234 · Cited by 394
Kléber, A. G., Riegger, C. B., & Janse, M. J. (1987) · Circulation Research · doi:10.1161/01.res.61.2.271 · Cited by 358
Loss, Restoration, and Maintenance of Plasma Membrane Integrity
McNeil, P. L., & Steinhardt, R. A. (1997) · The Journal of Cell Biology · doi:10.1083/jcb.137.1.1 · Cited by 339
Metadata
- Authors
- Délèze, J.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1970-07
- Volume
- 208
- Issue
- 3
- Pages
- 547-562
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2094665340
- Cited by
- 153
- References
- 0
- FWCI
- 3.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The recovery of resting potential and input resistance in sheep heart injured by knife or laser. https://app.cochat.ai/papers/10.1113/jphysiol.1970.sp009136
- The paper
- Délèze, J. (1970). The recovery of resting potential and input resistance in sheep heart injured by knife or laser. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1970.sp009136
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.