CoChat

The recovery of resting potential and input resistance in sheep heart injured by knife or laser

Open access
Délèze, J. · 1970 · The Journal of Physiology
Cited by 153

The DOI matches its Crossref record.

Abstract

1. A lesion 100 μ in diameter with well‐defined boundaries was made with a laser in Purkinje fibres from sheep hearts. The membrane potential and the input resistance recorded in the intact tissue at about 0·5 mm from the edge of the lesion were found to drop at the instant of injury. The corresponding decrease of input resistance fits quantitatively the transmission line theory applied to a cable terminated by a short circuit at the lesion. 2. The input resistance and the membrane potential were found to rise simultaneously during healing‐over. The membrane potential returned to its original level within 1 min. By then, the input resistance had settled either to the same value as before injury, or to a higher value matching quantitatively the theoretical resistance of a cable terminated by an infinite resistance at the lesion. 3. Neither membrane potential nor input resistance recovered in calcium‐free solutions. But healing‐over rapidly occurred when calcium was added to solutions that might otherwise differ widely in composition. 4. The transmission line model fits all observations if it is assumed that the injury causes a leak or short circuit in the ‘cable’ that is soon closed, or rendered open circuit, by the development of a new diffusion barrier in the presence of calcium ions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1970.sp009136

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Délèze, J.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1970-07
Volume
208
Issue
3
Pages
547-562
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2094665340
Cited by
153
References
0
FWCI
3.82
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.