Comparison of the reflex vasomotor responses to separate and combined stimulation of the carotid sinus and aortic arch baroreceptors by pulsatile and non‐pulsatile pressures in the dog
Open accessThe DOI matches its Crossref record.
Abstract
1. In the anaesthetized dog the carotid sinuses and aortic arch were isolated from the circulation and separately perfused with blood by a method which enabled the mean pressure, pulse pressure and pulse frequency to be varied independently in each vasosensory area. The systemic circulation was perfused at constant blood flow by means of a pump and the systemic venous blood was oxygenated by an extracorporeal isolated pump‐perfused donor lung preparation. 2. When the vasosensory areas were perfused at non‐pulsatile pressures within the normal physiological range of mean pressures, the reflex reduction in systemic vascular resistance produced by a given rise in mean carotid sinus pressure was significantly greater than that resulting from the same rise of aortic arch pressure. 3. On the other hand, when the vasosensory areas were perfused at normal pulsatile pressures and within the normal physiological range of mean pressures, there was no difference in the size of the reflex vascular responses elicited by the same rise in mean pressure in the carotid sinuses and in the aortic arch. 4. Whereas the vasomotor responses elicited reflexly by changes in mean carotid sinus pressure are modified by alterations in pulse pressure, those evoked by the aortic arch baroreceptors through changes of mean pressure are only weakly affected by modifications in pulse pressure. Evidence for this was obtained from single stepwise changes of mean pressure in each vasosensory area during pulsatile and non‐pulsatile perfusion, and from curves relating the mean pressure in the carotid sinuses or aortic arch and systemic arterial perfusion pressure. 5. The vasomotor response elicited by combined stimulation of the carotid sinus and aortic arch baroreceptors was greater than either response resulting from their separate stimulation. 6. When the mean perfusion pressures in the two vasosensory areas are changed together, the curve relating mean pressure to systemic arterial pressure during pulsatile perfusion of the areas is considerably flatter than that for non‐pulsatile perfusion. 7. Increasing the pulse pressure in the carotid sinuses or aortic arch caused a decrease in systemic vascular resistance, the response elicited from the carotid sinuses being the larger. 8. Altering the phase angle between the pulse pressure waves in the carotid sinuses and aortic arch had no effect on systemic vascular resistance. 9. In both vasosensory areas, increasing the pulse frequency caused a reduction in systemic vascular resistance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Human muscle nerve sympathetic activity at rest. Relationship to blood pressure and age
Sundlöf, G., & Wallin, B. G. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012170 · Cited by 601
Nucleus Tractus Solitarius—Gateway to Neural Circulatory Control
Andresen, M. C., & Kunze, D. L. (1994) · Annual Review of Physiology · doi:10.1146/annurev.ph.56.030194.000521 · Cited by 469
Pathophysiological basis of orthostatic hypotension in autonomic failure
Smit, A. A. J., Halliwill, J. R., Low, P. A., & Wieling, W. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.0001o.x · Cited by 387
“First, the observation that carotid sinus receptors respond more vigorously to rapid rather than slow changes in pressure makes it likely that they play the major role in the initial reflex adjustments (Angell-James & Daly 1970).”
BackgroundNeural organisation and control of the baroreceptor reflex
Spyer, K. M. (1981) · Reviews of Physiology, Biochemistry and Pharmacology · doi:10.1007/bfb0034536 · Cited by 335
Receptors under pressure. An update on baroreceptors.
Brown, A. M. (1980) · Circulation Research · doi:10.1161/01.res.46.1.1 · Cited by 256
Abboud, F. M., Eckberg, D. L., Johannsen, U. J., & Mark, A. L. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012612 · Cited by 241
Interactions Between Respiration and Circulation
De Burgh Daly, M. (1986) · Comprehensive Physiology · doi:10.1002/cphy.cp030216 · Cited by 232
Circulation to Skeletal Muscle
Shepherd, J. T. (1983) · Comprehensive Physiology · doi:10.1002/cphy.cp020311 · Cited by 208
Interaction of Cardiovascular Reflexes in Circulatory Control
Abboud, F. M., & Thames, M. D. (1983) · Comprehensive Physiology · doi:10.1002/cphy.cp020319 · Cited by 191
Baroreflex Control of Systemic Arterial Pressure and Vascular Bed
Sagawa, K. (1983) · Comprehensive Physiology · doi:10.1002/cphy.cp020314 · Cited by 182
Metadata
- Authors
- James, J. E. A., & Daly, M. D. B.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1970-08
- Volume
- 209
- Issue
- 2
- Pages
- 257-293
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2070308872
- Cited by
- 132
- References
- 0
- FWCI
- 6.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.