The DOI matches its Crossref record.
The visibility of transient changes of luminance
Open accessAbstract
1. The threshold intensities of various transient changes from a base line luminance in the mid‐photopic range have been measured. 2. Rectangular changes in luminance show no difference between increments and decrements, a threshold intensity decreasing inversely with durations up to 16 msec, a lesser reduction in threshold up to 64 msec and for longer durations a slight increase in threshold. 3. Two brief flashes separated by an interval show incomplete summation at 10 msec, almost no summation at 65 msec and a second reduction in threshold at 100 msec. 4. Two brief flashes in opposite directions negate each other at very small intervals but complement each other at longer intervals, maximally at 65 msec. 5. A model of the detector system is proposed that passes the stimulus wave form through a band‐pass filter and takes a running average of the variance of the filter output. Threshold is reached if this average attains a certain level. 6. The model satisfactorily accounts for the observations that any two wave forms occurring together and not exceeding a total of 100 msec in duration will interact so that the relationship between them at the combined threshold will be an ellipse; and that this ellipse will have no obliquity if one wave form is the differential of the other. 7. Measurements of the thresholds of two brief flashes separated by various intervals define the attenuation characteristics of the band‐pass filter invoked to explain the thresholds of repetitive stimuli. 8. The model reconciles the apparent disparity between the thresholds of single flashes of varying duration and pairs of flashes of varying interval. 9. The statistical efficiency of such a system is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Peripheral vision and pattern recognition: A review
Strasburger, H., Rentschler, I., & Jüttner, M. (2011) · Journal of Vision · doi:10.1167/11.5.13 · Cited by 943
Probability summation over time
Watson, A. B. (1979) · Vision Research · doi:10.1016/0042-6989(79)90136-6 · Cited by 588
Netravali, A. N., & Limb, J. O. (1980) · Proceedings of the IEEE · doi:10.1109/proc.1980.11647 · Cited by 451
Temporal interactions during paired-electrode stimulation in two retinal prosthesis subjects
Horsager, A., Boynton, G. M., Greenberg, R. J., & Fine, I. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5282 · Cited by 48
Optimization of Electrical Stimulation for a High-Fidelity Artificial Retina
Shah, N. P., Madugula, S., Grosberg, L., Mena, G., Tandon, P., Hottowy, P., Sher, A., Litke, A., Mitra, S., & Chichilnisky, E. J. (2019) · 2019 9th International IEEE/EMBS Conference on Neural Engineering (NER) · doi:10.1109/ner.2019.8716987 · Cited by 32
Metadata
- Authors
- Rashbass, C.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1970-09
- Volume
- 210
- Issue
- 1
- Pages
- 165-186
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1986727005
- Cited by
- 237
- References
- 0
- FWCI
- 2.41
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The visibility of transient changes of luminance. https://app.cochat.ai/papers/10.1113/jphysiol.1970.sp009202
- The paper
- Rashbass, C. (1970). The visibility of transient changes of luminance. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1970.sp009202
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.