The DOI matches its Crossref record.
Evidence for two types of sodium conductance in axons perfused with sodium fluoride solution
Open accessAbstract
1. Voltage clamp experiments were carried out on squid giant axons internally perfused with 300 m M‐NaF + sucrose. K‐free artificial sea‐water, −0·3 to 3·5° C, was used externally. 2. Membrane currents were corrected for capacitative and leakage components, and the resulting Na current was converted to Na conductance, gNa. An attempt was made to fit changes in gNa according to the Hodgkin—Huxley model, namely [Formula: see text]. According to the model ḡNa is a constant, m∞ and h∞ are steady‐state values which depend only on voltage, τ m−1 and τ h−1 are rate constants which also are functions only of voltage. 3. Stepwise depolarizations from the holding potential (−67 to −83 mV) to a potential which varied from −10 to +63 mV resulted in an exponential decline of h from its initial level to a final, non‐zero level. If the test depolarization was preceded by a positive prepulse (duration, 19–105 msec; voltage, −6 to 94 mV) the rate constant for h, τ h−1, was increased roughly threefold with practically no change in the final level. 4. The steady‐state level of h was studied by using prepulses of varying amplitude followed by a test depolarization. In one such experiment a value of 0·34 was obtained for a 105 msec prepulse to −49 mV. The same value for the steady level of h was obtained from analysing a record taken at +52 mV. If the potential was switched from −49 to +52 mV there was a transient increase in gNa although h∞ had the same value at these two potentials. 5. Recovery from depolarization was studied by repolarizing the fibre for varying lengths of time, then applying a test depolarization. If the first depolarization was strongly positive (for example, 70 mV), so that the steady level of h was large (0·39), the currents associated with the test pulse could not be fitted on the basis of an exponential increase in h during the recovery period. Rather, the results suggested that on repolarization h rapidly decreased initially, then slowly increased. 6. These results can be explained by assuming that h is given by the sum of two components, h1 and h2. Changes are represented kinetically by h1 ⇌ x ⇌ h2, where x signifies the inactive state. The distribution is shifted to the left at negative potentials and to the right for positive ones. The resulting Na conductance is comprised of two types: the first type, ḡNam3h1, is similar to the Hodgkin—Huxley system and underlines the usual transient increase in gNa associated with depolarization; the second type, ḡNam3h2, is maintained with depolarization and gives rise to a steady level of gNa.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Inactivation of the sodium channel. I. Sodium current experiments.
Bezanilla, F., & Armstrong, C. M. (1977) · The Journal of general physiology · doi:10.1085/jgp.70.5.549 · Cited by 1,500
Inactivation of the sodium channel. II. Gating current experiments.
Armstrong, C. M., & Bezanilla, F. (1977) · The Journal of general physiology · doi:10.1085/jgp.70.5.567 · Cited by 959
The variance of sodium current fluctuations at the node of Ranvier
Sigworth, F. J. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013426 · Cited by 775
Stys, P., Waxman, S., & Ransom, B. (1992) · The Journal of Neuroscience · doi:10.1523/jneurosci.12-02-00430.1992 · Cited by 662
Eckert, R., & Chad, J. E. (1984) · Progress in Biophysics and Molecular Biology · doi:10.1016/0079-6107(84)90009-9 · Cited by 608
Metadata
- Authors
- Chandler, W. K., & Meves, H.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1970-12
- Volume
- 211
- Issue
- 3
- Pages
- 653-678
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1990711838
- Cited by
- 163
- References
- 0
- FWCI
- 1.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evidence for two types of sodium conductance in axons perfused with sodium fluoride solution. https://app.cochat.ai/papers/10.1113/jphysiol.1970.sp009298
- The paper
- Chandler, W. K., & Meves, H. (1970). Evidence for two types of sodium conductance in axons perfused with sodium fluoride solution. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1970.sp009298
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.