The DOI matches its Crossref record.
Counting every quantum
Open accessAbstract
1. Human subjects were asked to rate both blanks and very dim flashes of light under conditions of complete dark adaptation at 7° in the periphery. The ratings used were 0, 1, 2, 3, 4, 5, and 6. 2. For one subject (B.S.) the distributions of ratings were approximately Poisson distributions. The data were consistent with each rating being the actual number of effective quantal absorptions plus the number of noise events. This subject was presumably able to count every rod signal (effective absorptions plus noise). 3. For two other subjects, the data were consistent with the ratings being one less (L.F.) and two less (K.D.) than the number of effective absorptions plus noise. They were able to count every rod signal beginning with 2 and 3 respectively. A fourth subject's erratic data could not be fitted. 4. The fraction of quanta incident at the cornea that resulted in a rod signal was estimated to be about 0·03 which is consistent with physical estimates of effective absorption for that retinal region. 5. A simulated forced choice experiment leads to an absolute threshold about 0·40 log units below the normal yes‐no absolute threshold. This and other results indicate that subjects can use the sensory information they receive even when only 1, 2 or 3 quanta are effectively absorbed, depending on the individual. Humans may be able to count every action potential or every discrete burst of action potentials in some critical neurone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Single Units and Sensation: A Neuron Doctrine for Perceptual Psychology?
Barlow, H. B. (1972) · Perception · doi:10.1068/p010371 · Cited by 1,730
Chapter 9 Visual adaptation and retinal gain controls
Shapley, R., & Enroth-Cugell, C. (1984) · Progress in Retinal Research · doi:10.1016/0278-4327(84)90011-7 · Cited by 885
Eye Smarter than Scientists Believed: Neural Computations in Circuits of the Retina
Gollisch, T., & Meister, M. (2010) · Neuron · doi:10.1016/j.neuron.2009.12.009 · Cited by 795
Single-photon detection by rod cells of the retina
Rieke, F., & Baylor, D. A. (1998) · Reviews of Modern Physics · doi:10.1103/revmodphys.70.1027 · Cited by 263
Bushell, W. C. (2009) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2009.04960.x · Cited by 12
Metadata
- Authors
- Sakitt, B.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1972-05
- Volume
- 223
- Issue
- 1
- Pages
- 131-150
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2116534762
- Cited by
- 171
- References
- 0
- FWCI
- 2.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Counting every quantum. https://app.cochat.ai/papers/10.1113/jphysiol.1972.sp009838
- The paper
- Sakitt, B. (1972). Counting every quantum. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1972.sp009838
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.