Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 349

The DOI matches its Crossref record.

The frequency response and other properties of single fibres in the guinea‐pig cochlear nerve

Open access
Evans, E. F.·1972·The Journal of Physiology

Abstract

1. Micro‐electrode recordings were obtained from over 100 single fibres in the cochlear nerve of the pentobarbitone or urethane anaesthetized guinea‐pig. The acoustic system was calibrated at the tympanic membrane and threshold sound level measurements so corrected. 2. The minimum thresholds of the fibres approached with 10–20 dB of the behavioural thresholds reported in the literature. Exceptions to this were fibres from preparations where there was evidence of malfunction of the cochlea either from abnormally low perfusion or local damage, and a few high frequency fibres. With these high threshold fibres excepted, the range of thresholds at a given frequency in any one animal was less than 20 dB. 3. The slopes of the low and high frequency cut‐offs of the frequency—threshold curves (‘tuning curves’) within 25 dB of minimum threshold, ranged from 10 to 60 and from 20 to 125 dB/octave respectively for fibres with characteristic frequencies below 2 kHz, increasing to 90–180 and 200–600 dB/octave respectively for fibres with characteristic frequencies at about 8 kHz. These slopes represent the minimum values for the high‐frequency cut‐offs, which increase towards 1000 dB per octave in some cases at higher levels above threshold. At 30–50 dB above threshold, the low frequency cut‐offs become suddenly less steep and approximate to 5 dB per octave. 4. The relative sharpness of the frequency—threshold curves, measured as the ‘Q10 dB’, i.e. the ratio of characteristic frequency to the band width at 10 dB above minimum threshold, ranged from 1 to 4 for fibres with characteristic frequencies below 2 kHz, to 3–15 for fibres with characteristic frequencies near 10 kHz. 5. The slopes and ‘Q10 dB’ measures of the frequency—threshold curves of most of the abnormally high threshold fibres approximated to, or were lower than those of analogous measurements of the guinea‐pig basilar membrane vibration patterns. 6. Four fifths of the cochlear nerve fibres had spontaneous discharge rates greater than 1/sec. No consistent relationship was observed between the rate of this activity and response properties, with the exception that nearly half of the high threshold fibres were silent. In these and other respects the response properties to tonal and click stimuli resembled those of cochlear nerve fibres in the cat. In no case was inhibition of the spontaneous discharge by single tones observed. 7. It is concluded that, contrary to earlier reports, the cochlear nerve fibres of the guinea‐pig are substantially more frequency selective than the existing measurements of the guinea‐pig basilar membrane displacement. In terms of band width, this discrepancy approaches a factor of ten. The finding of a considerable range of band widths within optimal preparations, and frequency—threshold curves approximating to the mechanical functions in fibres from pathological cochleas, provides circumstantial evidence for a physiologically vulnerable sharpening mechanism occurring within the cochlea subsequent to the displacement pattern of the basilar membrane.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1972.sp009984

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Metadata

Authors
Evans, E. F.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1972-10
Volume
226
Issue
1
Pages
263-287
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2132132466
Cited by
349
References
0
FWCI
8.45
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The frequency response and other properties of single fibres in the guinea‐pig cochlear nerve. https://app.cochat.ai/papers/10.1113/jphysiol.1972.sp009984
The paper
Evans, E. F. (1972). The frequency response and other properties of single fibres in the guinea‐pig cochlear nerve. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1972.sp009984

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.