Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 293

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Properties of sustained and transient ganglion cells in the cat retina

Open access
Cleland, B. G., Levick, W. R., Sanderson, K. J.·1973·The Journal of Physiology

Abstract

1. The functional basis for a sustained/transient classification of cat retinal ganglion cells has been strengthened by quantitative measurements of the sizes of the centre and surround components of receptive fields. Transient cells had larger surrounds than sustained; the distributions were non‐overlapping. Although the distributions of centre sizes overlapped, the transient cells had very significantly larger centres on average. 2. There were characteristic differences in area‐threshold and annulus‐threshold curves and shapes of responses to brief and long flashes of light, and relative differences in the nature of surround adaptation and maintained discharge rates. 3. The distinction of sustained from transient units survived over a wide range of backgrounds including the two principle reorganizations of function: relative weakening of surround components at low background; Purkinjě shift at high. 4. Sustained and transient units were differentially distributed in the retina: there was an overwhelming preponderance of sustained units in the area centralis. 5. It is proposed that the transient units are the so‐called multidendritedeep cells and the sustained units are the variously styled small ganglion cells.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1973.sp010105

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 293

Metadata

Authors
Cleland, B. G., Levick, W. R., & Sanderson, K. J.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1973-02
Volume
228
Issue
3
Pages
649-680
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2170009191
Cited by
293
References
29
FWCI
19.39
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Properties of sustained and transient ganglion cells in the cat retina. https://app.cochat.ai/papers/10.1113/jphysiol.1973.sp010105
The paper
Cleland, B. G., Levick, W. R., & Sanderson, K. J. (1973). Properties of sustained and transient ganglion cells in the cat retina. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1973.sp010105

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.