Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 159

The DOI matches its Crossref record.

Augmentation: A process that acts to increase transmitter release at the frog neuromuscular junction.

Open access
Magleby, K L, Zengel, J E·1976·The Journal of Physiology

Abstract

1. End‐plate potentials (e.p.p.s) were recorded from frog neuromuscular junctions bathed in Ringer solution containing increased Mg and decreased Ca to reduce transmitter release. Conditioning and testing stimulation was applied to the nerve to study a previously uncharacterized process which acts to increase e.p.p. amplitudes. We will refer to this process as augmentation. 2. Following repetitive stimulation augmentation decayed approximately exponentially over most of its time course with a mean time constant of about 7 sec (range 4‐10 sec) which is intermediate in duration between the time constants for the decay of facilitation and potentiation. 3 . The magnitude of agumentation increased with the duration of the conditioning stimulation. Assuming a multiplicative relationship between augmentation and potentiation, values of the magnitude of augmentation ranged from 0‐3 to 0‐6 following 50 impulses at 20/sec to 0‐5‐7‐8 following 600 impulses at 20/sec. (An augmentation of 0‐3 and 7‐8 would increase e.p.p. amplitudes 1‐3 and 8‐8 times, respectively.) 4. The time constant characterizing the decay of augmentation remained relatively constant as the duration of the conditioning stimulation was increased. 5. Augmentation as well as facilitation and potentiation resulted from an increase in the number of quanta of transmitter released from the nerve terminal. 6. Augmentation decayed faster at higher temperatures with a mean temperature coefficient, Q10, of about 3‐8. The corresponding Q10 for the decay of potentiation was found to be about 2‐4. 7. It is concluded that augmentation can be a significant factor in increasing transmitter release and will therefore have to be accounted for when studying the effects of repetitive stimulation on the function of the nerve terminal or when formulating models of transmitter release.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1976.sp011378

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 159

Metadata

Authors
Magleby, K. L., & Zengel, J. E.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1976-05
Volume
257
Issue
2
Pages
449-470
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2023573333
Cited by
159
References
0
FWCI
1.34
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Augmentation: A process that acts to increase transmitter release at the frog neuromuscular junction. https://app.cochat.ai/papers/10.1113/jphysiol.1976.sp011378
The paper
Magleby, K. L., & Zengel, J. E. (1976). Augmentation: A process that acts to increase transmitter release at the frog neuromuscular junction. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1976.sp011378

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.