Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 167

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A quantitative analysis of local anaesthetic alteration of miniature end‐plate currents and end‐plate current fluctuations.

Open access
Ruff, R L · 1977 · The Journal of Physiology

Abstract

1. The effect of the local anaesthetic QX222 on the kinetics of miniature end‐plate currents (m.e.p.c.s) and acetylcholine (ACh) induced end‐plate current (e.p.c) fluctuations was studied in voltage‐clamped frog cutaneous pectoris neuromuscular junctions made visible with Nomarski differential interference contrast optics. 2. In Ringer solution the m.e.p.c.s decayed with a single exponential time course and the e.p.c. fluctuation spectra were characterized by single Lorentzian functions, with the spectral cut‐off frequency well predicted by the m.e.p.c. decay rate. 3. In the presence of 0‐1‐0‐5 mm QX222 at‐50 to ‐100 mV holding potential both the e.p.c. fluctuation spectrum and the m.e.p.c. decay consisted of a fast and a slow component, with the cut‐off frequency of each spectral component predicted by the decay rate of the corresponding constituent of the m.e.p.c. 4. Hyperpolarization increased the decay rate and relative amplitude of the fast component of the m.e.p.c. and decreased the decay rate of the slow m.e.p.c. component. 5. With 0‐05 mm QX222 and ‐70 mV holding potential the m.e.p.c.s. and e.p.c. fluctuation spectra consisted of three components. The third component of the m.e.p.c. and e.p.c. spectra had nearly the same decay rate and cut‐off frequency as was found at the same end‐plate under equivalent conditions before drug exposure. 6. The kinetic predictions of four different schemes for local anaesthetic action were compared with observed m.e.p.c.s. and e.p.c. fluctuations. 7. Schemes in which the local anaesthetic acted by creating two kinetically distinct populations of acetylcholine receptors or by interacting with ACh receptor to produce a biphasic exponential decay of the end‐plate channel conductance did not accurately predict the e.p.c. fluctuation spectrum. 8. The variance of the e.p.c. fluctuations vanished at the reversal potential indicating that local anaesthetic action was not due to the presence of different ion selective end‐plate channels. 9. QX222 action could be explained by alteration of the ACh receptors such that they sequentially c‐hanged from one conductance state to another. A specific case in which QX222 binds to the ACh receptors in its open state creating a partially blocked state, was found to be the most parisimonious. 10. The conductance, gamma, of a single end‐plate channel was estimated from e.p.c. fluctuations. In Ringer's solution gama = 24‐4 +/‐ 1‐2 (s.d.) pmho. In the presence of 0‐1 mm to 0‐5 mm QX222 the effective single channel conductance, gamma, varied from 14‐2 to 1‐39 pmho. 11. gamma decreased with increased local anesthetic concentration, hyperpolarization, or decreased temperature. The variation in gamma is thought to reflect the dependence on the experimental conditions of the relative probability that the ACh receptors is in an open vs a partially blocked state.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1977.sp011659

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 167

Metadata

Authors
Ruff, R. L.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1977-01
Volume
264
Issue
1
Pages
89-124
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2077178194
Cited by
167
References
1
FWCI
6.52
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.