The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A quantitative analysis of local anaesthetic alteration of miniature end‐plate currents and end‐plate current fluctuations.
Open accessAbstract
1. The effect of the local anaesthetic QX222 on the kinetics of miniature end‐plate currents (m.e.p.c.s) and acetylcholine (ACh) induced end‐plate current (e.p.c) fluctuations was studied in voltage‐clamped frog cutaneous pectoris neuromuscular junctions made visible with Nomarski differential interference contrast optics. 2. In Ringer solution the m.e.p.c.s decayed with a single exponential time course and the e.p.c. fluctuation spectra were characterized by single Lorentzian functions, with the spectral cut‐off frequency well predicted by the m.e.p.c. decay rate. 3. In the presence of 0‐1‐0‐5 mm QX222 at‐50 to ‐100 mV holding potential both the e.p.c. fluctuation spectrum and the m.e.p.c. decay consisted of a fast and a slow component, with the cut‐off frequency of each spectral component predicted by the decay rate of the corresponding constituent of the m.e.p.c. 4. Hyperpolarization increased the decay rate and relative amplitude of the fast component of the m.e.p.c. and decreased the decay rate of the slow m.e.p.c. component. 5. With 0‐05 mm QX222 and ‐70 mV holding potential the m.e.p.c.s. and e.p.c. fluctuation spectra consisted of three components. The third component of the m.e.p.c. and e.p.c. spectra had nearly the same decay rate and cut‐off frequency as was found at the same end‐plate under equivalent conditions before drug exposure. 6. The kinetic predictions of four different schemes for local anaesthetic action were compared with observed m.e.p.c.s. and e.p.c. fluctuations. 7. Schemes in which the local anaesthetic acted by creating two kinetically distinct populations of acetylcholine receptors or by interacting with ACh receptor to produce a biphasic exponential decay of the end‐plate channel conductance did not accurately predict the e.p.c. fluctuation spectrum. 8. The variance of the e.p.c. fluctuations vanished at the reversal potential indicating that local anaesthetic action was not due to the presence of different ion selective end‐plate channels. 9. QX222 action could be explained by alteration of the ACh receptors such that they sequentially c‐hanged from one conductance state to another. A specific case in which QX222 binds to the ACh receptors in its open state creating a partially blocked state, was found to be the most parisimonious. 10. The conductance, gamma, of a single end‐plate channel was estimated from e.p.c. fluctuations. In Ringer's solution gama = 24‐4 +/‐ 1‐2 (s.d.) pmho. In the presence of 0‐1 mm to 0‐5 mm QX222 the effective single channel conductance, gamma, varied from 14‐2 to 1‐39 pmho. 11. gamma decreased with increased local anesthetic concentration, hyperpolarization, or decreased temperature. The variation in gamma is thought to reflect the dependence on the experimental conditions of the relative probability that the ACh receptors is in an open vs a partially blocked state.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interaction of Tetraethylammonium Ion Derivatives with the Potassium Channels of Giant Axons
Armstrong, C. M. (1971) · The Journal of General Physiology · doi:10.1085/jgp.58.4.413 · Cited by 929
Cited by
Local anaesthetics transiently block currents through single acetylcholine‐receptor channels.
Neher, E., & Steinbach, J. H. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012267 · Cited by 844
On the stochastic properties of single ion channels
Colquhoun, D., & Hawkes, A. G. (1981) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1981.0003 · Cited by 669
Lewis, C. A. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012629 · Cited by 394
Evidence That the M2 Membrane-Spanning Region Lines the Ion Channel Pore of the Nicotinic Receptor
Leonard, R. J., Labarca, C. G., Charnet, P., Davidson, N., & Lester, H. A. (1988) · Science · doi:10.1126/science.2462281 · Cited by 375
Ascher, P., Large, W. A., & Rang, H. P. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012958 · Cited by 291
Metadata
- Authors
- Ruff, R. L.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1977-01
- Volume
- 264
- Issue
- 1
- Pages
- 89-124
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2077178194
- Cited by
- 167
- References
- 1
- FWCI
- 6.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.