The DOI matches its Crossref record.
Site and mode of adrenaline action on chloride transport across the rabbit corneal epithelium.
Open accessAbstract
1. Membrane events accompanying adrenaline‐stimulated Cl secretion by the isolated rabbit corneal epithelium were investigated with micro‐electrodes. 2. Pulses of adrenaline (5 X 10(‐10) M final concentration) delivered to either side of the epithelium produced a transient decrease in epithelial resistance occuring at the outer membrane of the squamous cell. This response was reversible and could be blocked completely by total Cl substitution with SO4. 3. Adrenaline generally produced a small transient increase in epithelial potential occuring also at the squamous cell outer membrane. Reversal potentials obtained for the adrenaline response were 45‐1 mV for corneal potential and 22‐8 mV for outer membrane. 4. Adrenaline always hyperpolarized epithelial potential when the tear side was bathed in Cl‐free solution. Reversing the gradient (Cl‐free on the stromal side) slowly and consistently changed the response to a depolarization which reached a steady level after 2 hr. 5. The reversal potential of the outer membrane for the adrenaline response was found to be a semilogarithmic function of the tear side Cl concentration over a broad range with a slope of 56 mV/decade. The reversal potential was zero at a tear side Cl concentration of 41‐5 mM, which value may be taken to be representative of cell Cl concentration. 6. After abolishing the adrenaline response by perfusing both sides of the tissue with Cl‐free solution, reintroduction of Cl to the stromal side led to a recovery of the epithelial potential response in the hyperpolarizing direction. The recovery of the response was inhibited by ouabain (10(‐5) M). 7. The results supported the following model for the influence of adrenaline on anion transport in the epithelium: Cl is transported against an electrochemical potential gradient into the cells from the stromal side by an active process linked to Na‐k activated ATPase. Normally a slight gradient exists from cells to tears favouring the passive outward diffusion of Cl. This latter process is enhanged by adrenaline, which increases cell cyclic AMP, in turn increasing the passive Cl permeability of the outer cellular membrane.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Crypts Are the Site of Intestinal Fluid and Electrolyte Secretion
Welsh, M. J., Smith, P. L., Fromm, M., & Frizzell, R. A. (1982) · Science · doi:10.1126/science.6293054 · Cited by 358
Transport processes across the rabbit corneal epithelium: a review
Klyce, S. D., & Crosson, C. E. (1985) · Current Eye Research · doi:10.3109/02713688509025145 · Cited by 185
Self-citation
Metadata
- Authors
- Klyce, S. D., & Wong, R. K.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1977-04
- Volume
- 266
- Issue
- 3
- Pages
- 777-799
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2025520796
- Cited by
- 163
- References
- 0
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Site and mode of adrenaline action on chloride transport across the rabbit corneal epithelium. https://app.cochat.ai/papers/10.1113/jphysiol.1977.sp011793
- The paper
- Klyce, S. D., & Wong, R. K. (1977). Site and mode of adrenaline action on chloride transport across the rabbit corneal epithelium. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1977.sp011793
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.