The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Tension responses to sudden length change in stimulated frog muscle fibres near slack length
Open accessAbstract
1. Apparatus for applying a step change of length to an isolated muscle fibre is described. The step was complete in about 0·2 ms. 2. Effects of tendon compliance were eliminated by using a spot‐follower device and by gripping the tendons with metal clips close to the fibre ends. 3. The natural frequency of the force transducer was above 10 kHz. 4. Steps of various amplitudes and in either direction were applied to isolated muscle fibres about 6 mm long from the anterior tibial muscle of Rana temporaria during tetanic stimulation. Initial sarcomere length was 2·0‐2·2 μm, and temperature was 0‐3 °C. 5. The tension response to a step could be divided into four phases. The initial response was an apparently elastic change during the step itself (phase 1). After the step was completed there was a rapid partial recovery towards the original tension (phase 2, lasting 2‐5 ms), followed by a slowing or reversal of recovery (phase 3, 10‐50 ms), and finally a much slower return to the original tension (phase 4). Most of this paper is concerned with phases 1 and 2. 6. The initial tension change (phase 1) occurred synchronously with the applied length change, indicating that the fibres possess a compliance which is almost linear and almost undamped. Its stiffness is such that an instantaneous shortening of about 4 nm per half‐sarcomere would bring the tension to zero from its isometric value. 7. The absence of detectable damping during phase 1 indicates that the viscosity of a stimulated fibre is substantially less than the apparent viscosity of a fibre at rest. 8. The instantaneous force—extension curve approached the length axis at a sharp angle and a negative tension appeared at the force transducer when a very large step was applied. These observations suggest that the structures responsible for the stiffness of the fibre remain rigid when they are not under tension. 9. During the few milliseconds after the step (phase 2) the tension recovered part of the way toward the level which existed before the step. In shortening steps the time course of this recovery was adequately fitted by the sum of four exponential terms, and was similar in steps of different amplitude but with a time scale shorter the larger the step. In stretches the slow components were relatively larger than in releases. 10. The tension level, T2, approached during phase 2 depended only on the total amplitude of the step and not on the time course of the length change, provided it was complete in 1‐2 ms. The extreme tension reached during a step could thus vary widely without detectable change in T2. 11. With stretches and releases of up to about 3 nm per half‐sarcomere this early recovery was almost complete, so that the curve of T2 against step amplitude was nearly horizontal. With larger releases the line curved downwards, reaching zero in a release of about 14 nm per half‐sarcomere. 12. When the temperature was raised both the developed tension and the stiffness increased, but the relative increase was greater for tension than for stiffness. The amount of instantaneous shortening needed to bring tension to zero was therefore also increased. 13. A set of empirical equations is given which describe adequately the first few milliseconds of the tension change in response to any imposed time course of shortening. 14. The rapid elasticity and early tension recovery resemble the response of a combination of two elastic components and one viscous component. Reasons are given for preferring an interpretation in terms of an undamped compliance in series with a damped compliance (Voigt element) rather than an undamped elasticity in parallel with a series combination of viscous and elastic components (Maxwell element). 15. The rapid compliance does not correspond to the ‘series elastic component’ of two‐component theories of muscle contraction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The variation in isometric tension with sarcomere length in vertebrate muscle fibres
Gordon, A. M., Huxley, A. F., & Julian, F. J. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp007909 · Cited by 3,152
Self-citation
Cited by
Single myosin molecule mechanics: piconewton forces and nanometre steps
Finer, J. T., Simmons, R. M., & Spudich, J. A. (1994) · Nature · doi:10.1038/368113a0 · Cited by 1,915
Self-citationAdaptive control of mechanical impedance by coactivation of antagonist muscles
Hogan, N. (1984) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1984.1103644 · Cited by 1,041
Edman, K. A. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012804 · Cited by 759
Godt, R. E., & Lindley, B. D. (1982) · The Journal of general physiology · doi:10.1085/jgp.80.2.279 · Cited by 448
Elastic Energy Stores in Running Vertebrates
ALEXANDER, R. M. (1984) · American Zoologist · doi:10.1093/icb/24.1.85 · Cited by 411
Metadata
- Authors
- Ford, L. E., Huxley, A. F., & Simmons, R. M.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1977-07
- Volume
- 269
- Issue
- 2
- Pages
- 441-515
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1980685237
- Cited by
- 858
- References
- 1
- FWCI
- 18.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tension responses to sudden length change in stimulated frog muscle fibres near slack length. https://app.cochat.ai/papers/10.1113/jphysiol.1977.sp011911
- The paper
- Ford, L. E., Huxley, A. F., & Simmons, R. M. (1977). Tension responses to sudden length change in stimulated frog muscle fibres near slack length. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1977.sp011911
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.