The DOI matches its Crossref record.
The effects of position and skin temperature on the capillary pressures in the fingers and toes
Open accessAbstract
1. Direct measurements of the capillary pressure (Pc) were made in capillaries at the base of the nails of the fingers and toes of two subjects (the authors of this paper). 2. With the hand or foot at heart level, Pc varied over the range of 7‐70 cm H 2 O with mean values of 43 cm H 2 O in both the fingers and the toes. Pc was higher in the arterial limb (mean 49 cm H 2 O) than in the venous limb (mean 34 cm H 2 O) of the capillary loops. The plasma colloid osmotic pressures for the two subjects were 33 and 34 cm H 2 O. 3. For capillaries at heart level there was a strong positive correlation between Pc and skin temperature when the latter was varied over the range 23‐36 °C. 4. When the hand or foot was lowered, Pc increased less than the local arterial (Pa) and venous pressures (Pv). Furthermore the variation in Pc was reduced. In fourteen measurements of Pc made on capillaries in the toes of standing subjects, Pc was no more than 10 cm H 2 O greater than Pv. It is argued that the increase in the ratio (Pa — Pc)/(Pc — Pv) with hydrostatic load represents an increase in the ratio of pre‐ to post‐capillary resistance. 5. When Pv was increased by inflating a sphygmomanometer cuff around the upper arm, (Pa — Pc)/(Pc — Pv) increased in the hand held at heart level. These changes were similar to those seen with changes in position. 6. The implications of the results are discussed with respect to fluid balance between the blood and tissues. It is argued that since Pc in the warm hand was never less than the plasma colloid osmotic pressure, fluid is not reabsorbed from the tissues into the capillaries of the warm skin of the hand even at heart level. Compensatory changes in the circulation appear to minimise the filtration of fluid into the feet of the standing subject but the mechanism of these changes remains obscure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microvascular fluid exchange and the revised Starling principle
Levick, J. R., & Michel, C. C. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq062 · Cited by 1,183
Self-citationSignaling Mechanisms Underlying the Vascular Myogenic Response
Davis, M. J., & Hill, M. A. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.2.387 · Cited by 992
Pathophysiological mechanisms and therapeutic approaches in obstructive sleep apnea syndrome
Lv, R., Liu, X., Zhang, Y., Dong, N., Wang, X., He, Y., Yue, H., & Yin, Q. (2023) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-023-01496-3 · Cited by 477
Role of nocturnal rostral fluid shift in the pathogenesis of obstructive and central sleep apnoea
White, L. H., & Bradley, T. D. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2012.245159 · Cited by 348
Lymphatic Vessel Network Structure and Physiology
Breslin, J. W., Yang, Y., Scallan, J. P., Sweat, R. S., Adderley, S. P., & Murfee, W. L. (2018) · Comprehensive Physiology · doi:10.1002/cphy.c180015 · Cited by 341
Metadata
- Authors
- Levick, J. R., & Michel, C. C.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1978-01
- Volume
- 274
- Issue
- 1
- Pages
- 97-109
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1973919421
- Cited by
- 196
- References
- 0
- FWCI
- 6.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The effects of position and skin temperature on the capillary pressures in the fingers and toes. https://app.cochat.ai/papers/10.1113/jphysiol.1978.sp012136
- The paper
- Levick, J. R., & Michel, C. C. (1978). The effects of position and skin temperature on the capillary pressures in the fingers and toes. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1978.sp012136
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.