Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 290

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Effects of picrotoxin and strychnine on rabbit retinal ganglion cells: lateral interactions for cells with more complex receptive fields.

Open access
Caldwell, J H, Daw, N W, Wyatt, H J·1978·The Journal of Physiology

Abstract

1. The effects of picrotoxin and strychnine were tested on the receptive fields of direction sensitive cells, orientation sensitive cells, local edge detectors, uniformity detectors and large field units in the rabbit retina. 2. Picrotoxin eliminated the direction specificity and size specificity of 'on‐off' and 'on' directionally sensitive cells for both black and white objects. Picrotoxin also made 'on' directionally sensitive cells responsive to faster velocities. 3. Picrotoxin eliminated the orientation specificity of orientation sensitive cells, and changed the bar‐flank arrangement of the receptive field into a centre surround arrangement. Thus, the orientation specificity is due to inhibitory rather than excitatory mechanisms. 4. Picrotoxin altered the speed sensitivity of large field units so that they responded to slow speeds as well as fast ones, like centre surround Y cells. 5. Strychnine abolished the size specificity of local edge detectors and changed their speed specificity so that they responded to faster speeds. 6. Picrotoxin changed a uniformity detector into a sustained on centre cell. 7. Strychnine did not effect the direction specificity of directionally sensitive cells, the orientation specificity of orientation sensitive cells, or the speed specificity of large field units. Picrotoxin did not affect the size specificity of local edge detectors. 8. Picrotoxin and strychnine usually had opposing effects on the transient responses of these units to spots and annuli. In general picrotoxin prolonged and enhanced these responses at both on and off, and strychnine shortened them. 9. The effect of these drugs for every type of ganglion cell with complex receptive field properties was to make the receptive field more simple. The orientation selective cells, large field cells, 'on' direction selective cells and uniformity detectors seem to be centre surround cells with special properties that are abolished by these drugs. The 'on‐off' direction selective cells and local edge detectors still on‐off receptive fields, but in each case one of the drugs abolished the feature that was the basis for the cell's name.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1978.sp012233

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 290

Metadata

Authors
Caldwell, J. H., Daw, N. W., & Wyatt, H. J.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1978-03
Volume
276
Issue
1
Pages
277-298
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2072891349
Cited by
290
References
2
FWCI
6.51
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of picrotoxin and strychnine on rabbit retinal ganglion cells: lateral interactions for cells with more complex receptive fields. https://app.cochat.ai/papers/10.1113/jphysiol.1978.sp012233
The paper
Caldwell, J. H., Daw, N. W., & Wyatt, H. J. (1978). Effects of picrotoxin and strychnine on rabbit retinal ganglion cells: lateral interactions for cells with more complex receptive fields. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1978.sp012233

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.