CoChat

The membrane current of single rod outer segments

Baylor, D A, Lamb, T D, Yau, K W · 1979 · The Journal of Physiology

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

1. Outer segments of individual rods in the retina of the toad, Bufo marinus, were drawn into a glass pipette to record the membrane current. 2. Light flashes evoked transient outward currents. The peak response amplitude was related to flash intensity by a Michaelis equation with half‐saturating intensity about 1 photon mum‐2. 3. The saturating response amplitude ranged up to 27 pA and corresponded closely to complete suppression of the steady inward current present in darkness. 4. For a given cell the saturating response amplitude varied linearly with the length of outer segment within the pipette. This is consistent with a uniform density of light‐sensitive channels and negligible gradient of membrane potential along the outer segment. 5. Responses to bright flashes never showed the relaxation from an initial peak seen previously in intracellular voltage recordings, suggesting that the conductance change responsible for the relaxation does not occur in the outer segment. 6. Responses to local illumination of only the recorded outer segment were very similar to those obtained with diffuse light at the same intensity, indicating that peripheral rods made little contribution to the responses. 7. The spectral sensitivity of 'red' rods was consistent with a retinal1‐based pigment with lambda max = 498 +/‐ 2 nm. 8. The kinetics of the response were consistent with four stages of delay affecting action of the internal transmitter. Responses were faster at the basal end of the outer segment than at the distal tip. 9. Background light reduced the sensitivity to a superposed dim test flash and shortened the time course of the response, indicating that adapting light modifies the kinetics and gain of the transduction mechanism within the outer segment. 10. Responses to dim lights exhibited pronounced fluctuations which are attributed in the succeeding paper (Baylor, Lamb & Yau, 1979) to the quantal nature of light.

Overview

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1979.sp012715

Cites

0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

The publisher hasn’t deposited this paper’s reference list.

Cited by

See all 341

Metadata

Authors
Baylor, D. A., Lamb, T. D., & Yau, K. W.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1979-03
Volume
288
Issue
1
Pages
589-611
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W4385679502
Cited by
341
References
0
Citations by year
2026: 8 · 2025: 3 · 2024: 6 · 2023: 6 · 2022: 4 · 2021: 6 · 2020: 7 · 2019: 16 · 2018: 6 · 2017: 7 · 2016: 4 · 2015: 8 · 2014: 3 · 2013: 3 · 2012: 5
FWCI
2.65
Type
journal article
Language
en
Open access
closed
Locations
  • The Journal of Physiology (publishedVersion)
  • ANU Open Research (Australian National University) (submittedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Photoreceptor and optogenetics research
  • Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion channel regulation and function
Keywords
rod outer segments, rod photoreceptors, phototransduction, membrane currents, outer segment length, spectral sensitivity, retinal pigment, adaptation, quantal response, toad retina

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The membrane current of single rod outer segments. https://app.cochat.ai/papers/10.1113/jphysiol.1979.sp012715
The paper
Baylor, D. A., Lamb, T. D., & Yau, K. W. (1979). The membrane current of single rod outer segments. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1979.sp012715

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.