Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 182

The DOI matches its Crossref record.

Slow calcium and potassium currents across frog muscle membrane: measurements with a vaseline‐gap technique.

Open access
Almers, W, Palade, P T·1981·The Journal of Physiology

Abstract

1. A vaseline‐gap voltage‐clamp technique was used to record slow Ca2+ and K+ currents from frog skeletal muscle fibres loaded with the Ca2+ chelator EGTA. 2. K+ currents were increased when Mg2+ replaced external Ca2+, and they were abolished when internal K+ was replaced by tetraethylammonium (TEA+). Ca2+ currents could be studied in isolation in fibres loaded with (TEA)2EGTA. 3. Under maintained depolarization, Ca2+ currents slowly increase (half‐time of 35 msec or more at 25 mV) and then decline to a steady value. Decline under repolarization is rapid (half‐time of 6‐7 msec) and complete. During an action potential, the Ca2+ influx through this system is probably less than the influx observed with tracers. 4. Ba2+, Sr2+, Ca2+, Mn2+ and Mg2+ can carry current across the membrane; Ni2+ and Co2+ cannot. Ca2+ currents are weakly blocked by external Mg2+.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1981.sp013622

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 182

Metadata

Authors
Almers, W., & Palade, P. T.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1981-03
Volume
312
Issue
1
Pages
159-176
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2070560195
Cited by
182
References
0
FWCI
7.11
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Slow calcium and potassium currents across frog muscle membrane: measurements with a vaseline‐gap technique. https://app.cochat.ai/papers/10.1113/jphysiol.1981.sp013622
The paper
Almers, W., & Palade, P. T. (1981). Slow calcium and potassium currents across frog muscle membrane: measurements with a vaseline‐gap technique. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1981.sp013622

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.