Voltage noise measurements across the pancreatic beta‐cell membrane: calcium channel characteristics.
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
1. Membrane potential fluctuations were measured in cells from mouse Islets of Langerhans identified as beta‐cells by the characteristic pattern of electrical activity induced by 11 mM‐D‐glucose. 2. The membrane potential was controlled by adjusting the external potassium concentration, [K+]o, keeping the sum [Na+]o plus [K+]o constant. In the absence of glucose, when [K+]o is raised, the resulting depolarization is accompanied by a significant increase in voltage noise. 3 The amplitude and time course of the voltage noise were measured under various experimental conditions. The variance of the fluctuating voltage decreased monotonically along the depolarization induced by sudden increase in [K+]o, suggesting a monotonic reduction in the number of elementary events. 4. The frequency characteristics of the excess noise could be analysed as the sum of 1/f and 1/f2 components. While the 1/f component remained unaffected by the external application of 20mM‐tetraethylammonium (TEA) and either 2 mM‐Mn2+ or 2 mM‐Co2+, the 1/f2 component was suppressed by both Mn2+ and Co2+. 5. The corner frequency, fc, of the 1/f2 component depended on membrane potential, which was adjusted by adjusting the [K+]o jump. These results support the idea that fc in these experiments is a measure of the channel relaxation. 6. Measurements of the input resistance in the frequency range from 0 to 25 Hz were used to obtain a rough estimate of the size of the channel conductance as 5 x 10(‐12) omega (‐1).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The effect of sodium ions on the electrical activity of the giant axon of the squid
Hodgkin, A. L., & Katz, B. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004310 · Cited by 3,520
Henquin, J.-C., & Lambert, A. E. (1974) · Diabetes · doi:10.2337/diab.23.12.933 · Cited by 58
Cited by
Electrophysiology of the pancreatic β-cell
Ashcroft, F. M., & Rorsman, P. (1989) · Progress in Biophysics and Molecular Biology · doi:10.1016/0079-6107(89)90013-8 · Cited by 1,127
Molecular Biology of Adenosine Triphosphate-Sensitive Potassium Channels*
Aguilar-Bryan, L., & Bryan, J. (1999) · Endocrine Reviews · doi:10.1210/edrv.20.2.0361 · Cited by 698
Gembal, M., Gilon, P., & Henquin, J. C. (1992) · Journal of Clinical Investigation · doi:10.1172/jci115714 · Cited by 494
Glucose-sensing mechanisms in pancreatic β-cells
MacDonald, P. E., Joseph, J. W., & Rorsman, P. (2005) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2005.1762 · Cited by 352
Santos, R. M., Rosario, L. M., Nadal, A., Garcia-Sancho, J., Soria, B., & Valdeolmillos, M. (1991) · Pfl�gers Archiv European Journal of Physiology · doi:10.1007/bf00550880 · Cited by 350
Metadata
- Authors
- Atwater, I., Dawson, C. M., Eddlestone, G. T., & Rojas, E.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1981-05
- Volume
- 314
- Issue
- 1
- Pages
- 195-212
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2003231710
- Cited by
- 51
- References
- 2
- FWCI
- 1.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Voltage noise measurements across the pancreatic beta‐cell membrane: calcium channel characteristics. https://app.cochat.ai/papers/10.1113/jphysiol.1981.sp013701
- The paper
- Atwater, I., Dawson, C. M., Eddlestone, G. T., & Rojas, E. (1981). Voltage noise measurements across the pancreatic beta‐cell membrane: calcium channel characteristics. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1981.sp013701
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.